Current Revision posted to RAM | STAAD Wiki by Sye on 5/24/2017 6:56:59 PM
Applies To | |||
Product: | STAAD.Pro | ||
First Affected Version: | |||
Found in Version: | 20.07.11.82 | ||
Released in Version: | |||
Environment: | All | ||
Area: | Post Processing | ||
Subarea: | |||
Issue #: | 680054 |
Problem Description
For a load combination a involving dynamic load case ( like response spectrum, time history ), when member forces are printed in STAAD output using PRINT LOAD ENVELOPE or PRINT MEMBER FORCES commands, incorrect values are reported at the end node. Forces at start and all intermediate sections are reported correctly.
Workaround
The member forces reported in the Post-processing mode ( in the Beam End Forces and Beam Force detail tables ) are correct and may be used.
Solution
This will be addressed in the STAAD.Pro CE release planned for July 2017.
See Also
Tags: 680054, 20.07.11.82, end section, member forces, COMBINATION, Known Issues