Revision 4 posted to RAM | STAAD Wiki by Sye on 11/28/2016 7:16:11 PM
Applies To | |||
Product(s): | STAAD.Pro | ||
Version(s): | All | ||
Environment: | N/A | ||
Area: | Design | ||
Subarea: | American Steel Design | ||
Original Author: | Bentley Technical Support Group | ||
I am using tapered tubular section properties in my model. When I try to design those members using the AISC code I get the message
THIS VERSION DOES NOT DESIGN TAPERED POLE SECTIONS (MEMBER 1). What does this error message mean?
The AISC code currently does not have the rules for designing tubular sections which are 6 sided, 8 sided, 12 sided, etc. That is why you cannot currently design them per the AISC code.
There is a code from ASCE called the ASCE publication # 72. That document contains the rules for designing these shapes. Those rules are implemented in STAAD's transmission tower code, and if you have purchased that code, you should be able to design them.
Tags: LRFD, AISC ASD, AISC 360, tapered pole, tubular section