Design of Tapered members as per AISC 360-05/10 may be incorrect

$
0
0
Revision 1 posted to RAM | STAAD Wiki by Sye on 11/24/2016 12:57:13 AM

 Applies To 
 Product:STAAD.Pro
First Affected Version:
 Found in Version:20.07.11.45
Released in Version:20.07.11.50
Environment:All
 Area: Design
Subarea:AISC 360
 Issue #:329816

Problem Description

For tapered member design as per AISC 360-05 code, design results are coming out different when members are designed in groups vs individually. This has been specifically observed when the first member in the design command block is a TRUSS member and the list of members to be designed included tapered members as part of it..

Steps to Reproduce

Run an appropriate model with Tapered member and check the results of design for the two cases
a. using an individual CHECK CODE for each member
b. using a CHECK CODE for a LIST of members
Results seem to differ.

.

Workaround

Design the tapered members individually each with its own CHECK CODE command

Solution

This issue is currently active and a solution is awaited
The issue is addressed in 20.07.11.50

See Also

Tags: First 20.07.11.45, tapered, STAAD.Pro, AISC 360, known issue, defect