Current Revision posted to RAM | STAAD Wiki by Sye on 11/19/2016 12:54:55 AM
Applies To | |||
Product: | STAAD.Pro | ||
First Affected Version: | |||
Found in Version: | 20.07.11.50 | ||
Released in Version: | 20.07.11.70 | ||
Environment: | All | ||
Area: | Design | ||
Subarea: | IS 800 2007 | ||
Issue #: | 358709 |
Problem Description
The design of double angles as per IS800:LSD code is incorrect when Iy>Iz. The cross sectional properties for Y and Z axes got reversed due to which the design is being done incorrectly.
Steps to Reproduce
- Design a double angle section ( having Iy > Iz ) as per IS800-2007
- Check the Iy and Iz values reported in the analysis output file as part of design output.
- The values are reversed.
Workaround
None
Solution
This has been addressed in 20.07.11.70
See Also
Tags: STAAD.Pro, 20.07.11.70, IS 800, double angle, known issue, defect, First 20.07.11.50