Revision 1 posted to RAM | STAAD Wiki by Sye on 11/19/2016 12:29:25 AM
Applies To | |||
Product: | STAAD.Pro | ||
First Affected Version: | |||
Found in Version: | 01.02.03.00 | ||
Released in Version: | |||
Environment: | All | ||
Area: | Area1; Area2 | ||
Subarea: | N/A | ||
Issue #: | 376915 |
Problem Description
Slenderness calculation and hence compression capacity caclulation for double angle sections as per IS800:2007 is incorrect when Iy>Iz.
Steps to Reproduce
- Design a double angle section as per IS800-2007
- Check the slenderness ratio reported in the analysis output file.
Workaround
None
Solution
This has been addressed in 20.07.11.70
See Also
Tags: slenderness, STAAD.Pro, 20.07.11.70, First 20.07.11.33, IS 800, double angle, known issue, defect