Slenderness calculation for double angles as per the IS800-2007 is incorrect when Iy > Iz

$
0
0
Revision 1 posted to RAM | STAAD Wiki by Sye on 11/19/2016 12:29:25 AM

 Applies To 
 Product:STAAD.Pro
First Affected Version:
 Found in Version:01.02.03.00
Released in Version:
Environment:All
 Area: Area1; Area2
Subarea:N/A
 Issue #:376915

Problem Description

Slenderness calculation and hence compression capacity caclulation for double angle sections as per IS800:2007 is incorrect when Iy>Iz.

Steps to Reproduce

  1. Design a double angle section as per IS800-2007
  2. Check the slenderness ratio reported in the analysis output file.

Workaround

None

Solution

This has been addressed in 20.07.11.70

See Also

Tags: slenderness, STAAD.Pro, 20.07.11.70, First 20.07.11.33, IS 800, double angle, known issue, defect