ACI 318 Shear Design Gravity Columns for Seismic Provisions

$
0
0
Revision 1 posted to RAM | STAAD Wiki by Karl G on 10/14/2016 6:45:54 PM

 Product(s):RAM Concrete Column
 First Affected Version:
Found in Version:14.07.01.00
Fixed in Version15.04.00.00
 Environment:N/A
 Area:Design
 Subarea:N/A
 Defect Number:241727

Problem Description

Gravity concrete columns in structures assigned to SDC D, E, or F may have been designed incorrectly for shear.

ACI GRAVITY COLUMN SHEAR DESIGN UNDER EARTHQUAKE FORCES*: In columns not designated as part of the seismic force resisting system, with SDC  D, E or F; and whose factored gravity axial forces were greater than the specified by ACI 318 11, at 21.13.4.3 it didn't meet the referenced requirements of 21.6.5 and 21.6.4. Effect: The shear design of Gravity columns with SDC D, E or F may have been inadequate.

Reason

ACI 318-11 21.13.4.3 requires gravity columns in high seismic areas subject to high axial loads to be designed using the provisions for transverse reinforcement in 21.6.4 and 21.6.5. These provisions were not checked by the program.

Solution

Problem corrected in version 15.04.00.00.

Tags: design, 15.04.00, Column, RAM Structural System, ACI 318, known issue, seismic, Ram Concrete