Reported Major and Minor Shear Values Mismatched in RAM Concrete Column for non-ACI Design Codes

$
0
0
Revision 1 posted to RAM | STAAD Wiki by Karl G on 10/14/2016 6:19:17 PM

 Product(s):RAM Concrete Column
 First Affected Version:
Found in Version:15.01.00.00
Fixed in Version15.04.00.00
 Environment:N/A
 Area:Report
 Subarea:N/A
 Defect Number:374420

Problem Description

In the Concrete Column Design Report, the major axis shear was reported as the minor axis shear and vice versa when any code other than an ACI 318 design code was selected. This was a reporting error only and did not affect the design.

Reason

Different conventions were used by the program in the analysis and design components.

Solution

Problem corrected in version 15.04.00.00.

See Also

[[ACI 318 Column Shear Capacity]]

Tags: 15.04.00, Column, RAM Structural System, known issue, Ram Concrete, Report