Is there a way to tell STAAD which load combination to check?

$
0
0
Current Revision posted to RAM | STAAD Wiki by Steve Crabtree on 6/15/2016 1:36:04 PM

  
 Applies To 
  
 Product(s):STAAD.Pro
 Version(s):All
 Environment: N/A
 Area: Design
 Subarea: American Steel Design
 Original Author:Bentley Technical Support Group
  

STAAD is checking deflection for beams or girders for all the load combinations in my model. Is there a way to tell STAAD which load combination to check?

You have to use the LOAD LIST command to achieve this. Supposing you want to check deflection for combination cases 81 and 82. And assume that L/Deflection has a limit of 240. The command sequence required to achieve this is

LOAD LIST 81 82
PARAMETER
CODE AISC
DFF 240 ALL
CHECK CODE ALL

However, after these commands, you have to reset DFF to a very small number so that deflection does not become a criteria for any further design operations. That is because, once a parameter is specified in STAAD, it stays that way till it is changed again. So, after the above, you need to specify

PARAMETER
CODE AISC
DFF 1 ALL