Multiple Floor Spectrum Generation Block Not Allowed

$
0
0
Revision 1 posted to RAM | STAAD Wiki by Steve Crabtree on 6/14/2016 1:26:15 PM

  
 Applies To 
  
 Product(s):STAAD.Pro
 Version(s):All
 Environment: N/A
 Area: Analysis
 Subarea: Response Spectrum Analysis
 Original Author:Bentley Technical Support Group
  

I am running an analysis and getting an error “Multiple Floor spectrum Generation block not allowed”. What does it mean ?

It seems like multiple blocks of the generate floor spectrum command has been specified in the file. STAAD.Pro only allows one such block as shown next

 

GENERATE FLOOR SPECTRUM

END FLOOR SPECTRUM

 

One can have floor spectra reported for multiple floors and in various directions but all these have to be specified as part of the single generate floor spectrum command block. The Technical Reference Manual section 5.32.10.3 titled Floor Spectrum Response contains details on specifying the floor spectrum input.