Revision 1 posted to Structural Analysis Wiki by Seth Guthrie on 3/3/2016 11:55:21 PM
Applies To | |||
Product: | Ram Connection | ||
First Affected Version: | 11.00.00.164 | ||
Found in Version: | 11.00.00.177 | ||
Fixed in Version: | |||
Environment: | All | ||
Area: | General | ||
Subarea: | N/A | ||
Issue #: | 338403 |
Problem Description
When trying to assign a CBB_SP template to a CBB Joint the following error comes up;
[Error] Assignment errors for joint 1
[Information] Internal design error in the connection. Please contact technical support.
Reason
Affects Ram Connection for Ram Structural System or Ram Elements.
Solution
The problem will be corrected in the next release. Alternatively, assign a CBB_DA connection template to the joint, then change the connection to the column to be a single plate.
Tags: GENERAL, Gusset, RAM Connection, Single plate, known issue, Joint