Revision 1 posted to Structural Analysis and Design - Wiki by Karl G on 4/7/2015 7:10:41 PM
Applies To | |||
Product(s): | RAM Elements | ||
Version(s): | 12.01.00.29 | ||
Environment: | N\A | ||
Area: | Analysis | ||
Subarea: | N\A | ||
Original Author: | Karl Gullerud, Bentley Technical Support Group | ||
Problem
Frame Type for Braced Frames Connection Module
Only moment frame types are included for frame type in the main program.
Braced frame types can be assigned in the Connection Pad. However, these
are not saved with the connection.
TR Number: 70830
Product: RAM Elements (Advanse) V8i
Version: 12.05.00.000
Area: General, Problem ID#: 70797, TROUBLEREPORT
Solution
TR Number: 70830
Workaround:
None
See Also
Tags: SELECTsupport; Ram Elements; RamFE; Analysis; Shells; Temperature, Migrated