Applies To | |||
Product(s): | STAAD.Pro | ||
Version(s): | ALL | ||
Environment: | ALL | ||
Area: | Analysis | ||
Subarea: | Time History Analysis | ||
Original Author: | Sye Chakraborty, Bentley Technical Support Group | ||
I am carrying out a concrete design but my design parameters are being ignored by STAAD.Pro during the design. Why ?
Ensure that the design parameters are specified before the design commands in the input editor. If these parameters appear after the design command, the design process will not use these and will continue to use the default values. The two scenarios are explained below
Incorrect sequence of commands ( design parameters will be ignored by STAAD.Pro )
…
START CONCRETE DESIGN
CODE ACI
DESIGN ELEMENT 63 67 71
CLB 0.125 MEMB 63 67 71
FC 576 MEMB 63 67 71
END CONCRETE DESIGN
…
Correct sequence of commands ( design parameters will be considered by STAAD.Pro )
…
START CONCRETE DESIGN
CODE ACI
CLB 0.125 MEMB 63 67 71
FC 576 MEMB 63 67 71
DESIGN ELEMENT 63 67 71
END CONCRETE DESIGN
…
Although the example above relates to concrete design, the same is true for ANY other design ( like steel, timber, aluminum etc. ) as well.