Quantcast
Channel: RAM | STAAD | ADINA Wiki
Viewing all 8748 articles
Browse latest View live

iTwin Analytical Synchronizer CONNECT Edition V12 Update 1 Patch 1

$
0
0
Current Revision posted to RAM | STAAD Wiki by Wentao Zhang on 12/13/2021 10:40:57 PM

Release Date: (COMING SOON) 20th December 2021

Release Name: iTwin Analytical Synchronizer CONNECT Edition V12 Update 1 -  Patch 1

Release Version: 12.01.01.01

This is a Patch Release and addresses the below items:

  • Updated Security Components to adhere to Security Requirements

 

Download Instructions

After signing into the CONNECTION Center, select Software Downloads under My Services. Once on the Software Fulfillment page, the installer can be located by performing a search on “iTwin Analytical Synchronizer”. Direct Software Downloads link.

Subscription Entitlement Service (SES) 

This product version utilizes Subscription Entitlement Service, which is not supported by SELECT activation key(s). SES is a free service, featuring new behavior to enhance your organization’s user administration and security with mandatory user sign-in via CONNECTION Client to access the application. If you are already signed in to the CONNECTION Client, you have met this prerequisite. If you have not, please refer to the Administrator's Resource Center and/or contact your administrator for assistance in the registration and sign-in process. 


Analytical Design Review

$
0
0
Current Revision posted to RAM | STAAD Wiki by Wentao Zhang on 12/14/2021 5:30:34 AM

Parent Topic - iTwin Services for Engineering Analysis

Design Review allows the viewing of any 3D iModel in the browser for collaboration purpose. For general navigation within Design Review see below:

Learn how to initiate participate in a collaborative, real-time, 3D design review session. 

www.youtube.com/watch

Analytical Design Review Mode

The analytical and design results widget extends review capabilities so engineers can collaborate more productively without recourse to the original desktop application that produced the analytical design.

If enabled, you can enter the Analytical and Design Review Mode by clicking on:

Once enabled you can see analytical design visualization and member properties. These features are only available within Analytical Design Review Mode.

If an iModel does not contain results to display you will be alerted with below prompt:

Ensure your source applications have included Design Results during "Push to Cloud" operation.

For STAAD, ensure "Design results" checkbox is selected:


You know you have successfully activated Analytical Design review mode when you see the below in Design Review:

The Analysis and Design Visualization Widget provides selection of visualizations (grouping of pertinent members to a property value) along with on screen text label options.

On screen labels can be toggled on and off via the eye icon as well as have its text size modified via the magnifying glasses.

Click “cross” to leave Analytical Design Review mode.

 

Utilization Ratios and other Visualizations

Visualization color code and group members according to a select list of member properties. Utilization Ratios is enabled by default and can be changed via the dropdown.

Any Visualization is a grouping of members according to a certain property. The Legend tab displays the color corresponding to the value as well as the member count.

For example, if Section Visualization is selected. The properties pane would have its Legend tab updated to show the section names present in the model and member count next to each section name value.


Member Properties

While within Analytical and Design Visualization mode. Click on any member of interest to view its analytical properties in the information pane.

You can further drill down to sub properties to investigate the constituent checks of summary results. The member properties pane will get updated whenever a new member is selected.

Member Properties Grouping and Labels

Within Member Properties, you can the view corresponding Visualization by directly clicking on the Property Name. For example - clicking "Member Type" is the equivalent of selecting the "Member Type" visualization dropdown.

is then equivalent to:

Clicking on  button on any property of interest and it will be shown drawn on screen as a text label. 

Size and visibility of text labels can be modified via the Label Options control:

Strength Check Utilization Ratios

Utilization Ratios display demand/capacity % of members shown on screen. Members that have not been designed or assigned a ratio are greyed out.

Strength Check Utilization Visualization in particular offers additional editable "Legend" tab to allow the customization of the bounds and corresponding visualization colors for the ranges. Utilization ratios greater than 1 are fixed to Red.

Visibility of the members corresponding to each range of utilization ratio values can be toggled on/off via the eye icon 

Enter valid numbers (0.00 - 1.00) in the text range box to change the utilization ratio values in each range. 

Click on the color square for each utilization ratio range to modify its display color: 

 

 

Special Considerations

After using tools such as Orbit and Pan  be sure to exit the selected tool by right clicking once.

Regardless which active tool you have selected you can always return to the capabilities listed on this page by click on Analysis and Design Visualization widget 

Distorted graphics in STAAD.Pro on Dell Alienware computers

$
0
0
Revision 4 posted to RAM | STAAD Wiki by DHIMAN BANERJEE on 12/14/2021 6:42:15 PM

It has been observed that on certain computers use of STAAD.Pro rendering of the icons in the ribbons and workflows is distorted. Investigation on this has identified the cause to be related to DELL machines which runs AWCC Service that is AlienWare Command Center. 

The solution to this issue : 

  1. Ensure STAAD.Pro is closed. 
  2. In Windows explorer, navigate to the folder C:\ProgramData\A-Volute\DellInc.AlienwareSoundCenter\Modules\ScheduledModules\Configurator
  3. Open the any text editor (like notepad, notepad++) in administrator mode and open the BlackApps.dat
  4. Add the following list of executables at the end of the BlackApps.dat

    SXP.exe

    Bentley.Staad.AutoLoadCombRuleManager.exe

    Bentley.Staad.Editor.exe

    Bentley.Staad.exe

    Bentley.Staad.Licensing.Configuration.exe

    Bentley.Staad.ScriptEditor.exe

    Bentley.Staad.UnitConverter.exe

    Calculator.exe

    SectionDBManager.exe

  5. Save the BlackApps.dat file 
  6. Open Task Manager and go to 'Services' and search for 'AWCCService' - Right click and 'Restart'
  7. Launch STAAD.Pro and the problem should be fixed

Similar issues may occur with software that uses similar technology to STAAD.Pro as these applications may benefit from similar style solution by adding the executable in the exclusion list as above.

References

Icons in the side panel are distorted

$
0
0
Revision 1 posted to RAM | STAAD Wiki by Payel on 12/14/2021 8:01:37 PM

 Applies To 
 Product(s):RAM Connection
 Version(s):13.06.00.213
 Environment: N/A
 Area: General
 Original Author:Bentley Technical Support Group

Problem Description

It has been observed that on few machines using RAM Connection, while hovering the mouse on icons in the side panel, they look distorted.

Reason

Investigation on this has identified the cause to be related to DELL machines which runs AWCC Service that is AlienWare Command Center. 

Steps to Resolve

  1. Exit out from RAM Connection. 
  2. Open Windows explorer, navigate to the folder C:\ProgramData\A-Volute\DellInc.AlienwareSoundCenter\Modules\ScheduledModules\Configurator,
  3. Add the following list of executables at the end of the BlackApps.dat
    RAMConnection.exe
    RAMConnStandalone.exe
  4. Save the BlackApps.dat file .
  5. Open Task Manager and go to 'Services' and search for 'AWCCService' - Right click and 'Restart'.
  6. Launch RAM Connection and it should run fine.

Similar issues may occur with RAM Elements; adding the executable in the exclusion list as above will correct the problem.

P.S. The folder ProgramData from step 2 above, may be not visible to you; you should check with your IT group on that.

See Also

Distorted graphics in STAAD.Pro on Dell Alienware computers

Structural Product TechNotes And FAQs

Tags: Graphical distortion in RAM Conncetion, graphics, RAM Connection, Icons are distorted

RAM SS Gravity Loads [FAQ]

$
0
0
Current Revision posted to RAM | STAAD Wiki by Seth Guthrie on 12/14/2021 9:25:01 PM
 Product(s):RAM Structural System; Ram Steel
 Version(s):All
 Area: Modeling; Analysis
 Original Author:Bentley Technical Support Group

Are the applied surface loads cumulative?

No, in RAM Structural System only the top applied surface load counts. The underlying loads are not deleted however, so if you delete the top load you can see the original load underneath. If too many load layers are applied to a model, a polygon error can occur when processing the loads. For this reason it is always best to remove any existing surface loads before modeling new layers.

Also note, this is different than the behavior in RAM Concept. In that program, overlapping surface loads are cumulative. Consequently, when Direct Gravity loads are imported from RAM SS into Concept, they are converted into equivalent separate polygons that do not overlap.

Is the structure self-weight included in the loads?

That depends on the settings under RAM Manager - Criteria - Self-Weight. Here the user can automatically include beam, column, wall or deck self-weight. Note, self-weight is never included for open web steel joists or vertical braces.

On the right hand side of the dialog box are the settings for self-weight as it applies to the building mass which is used for seismic loads, dynamic analysis and for P-Delta calculations.

For composite beam design, the self weight is always considered part of the Construction Dead Load. Hence, if all the self weight options are turned on, and there is no other load present during construction, the user applied CDL might be zero.

For open web steel joist systems it's important to note that no self-weight is applied for the steel joists. The reason for this is primarily that the unit weight of steel joists can vary depending on the manufacturer and the configuration of the diagonals. The user should always include extra dead load in the surface loads to account for estimated joist self weight.

In order for the steel gravity beam and column self weight mass to be considered in RAM Frame, it is imperative that those modules be run first, using the design-all process. So long as the RAM Manager indicates a green light next to each of those modules, RAM Frame should have the latest member self weight data available. Freezing the design of all gravity beams and columns is another way to ensure that member self weights are always considered.

Steel column self-weight is based on the column length from story to story, plus or minus any elevation offsets, times the section area and steel density. We do not increase the self-weight based on splices being a few feet above the story datum. 

Note, in RAM Frame, under Loads - Masses, the program calculated diaphragm mass totals can be overridden with User Specified values, normally using calculated masses is advised. There is a similar dialog box for the total Gravity Loads which is used to determine program generated notional loads.

Is the additional weight of concrete due to beam sag or "ponding" considered?

No, the self-weight of the deck is based on the thickness and weight parameters set in the Modeler - Deck Properties. When beams sag under the weight of the deck it is a common practice for the topping concrete to be leveled off which adds additional weight to the system assuming it's not cambered or shored. This additional weight should be incorporated into the applied construction dead loads (and masses).

How is the self weight of a Concrete Beam determined?

The program calculates rectangular beam unit self-weight based on the area of the beam times the "Unit Weight of Self weight". The other "Unit Weight" parameter is only used in calculating the elastic modulus, E, of the member.
The Concrete slab can independently be included in the self weight, so in cases where there is a concrete slab and rectangular concrete beams the weight of the concrete times the thickness of the slab and the width of the beam is double counted.

 
To alleviate this problem, "T" shaped beam sections are handled differently. With T beams, it's only the area of the stem below the slab that is applied as the beam self weight.

 .

How are partition loads handled.

The Partition Load is an additional Live Load; it is treated as an unreducible Live Load and will not be reduced. It is in addition to the loads specified as Live Load. Partition loads are defined variously by the Codes, some as Dead Load and some as Live Load. For those codes that define Partition loads as an unreducible Live Load, those should be specified here. For those Codes that define Partition loads as a Dead Load or as part of the regular Live Load, those should be included as part of the Dead Load or Live Load accordingly.

Unlike construction live load, the partition live load is not a portion of the total live load entered. You can apply 0 Live Load and still apply 15 psf Partition Live load, for example.

Partition loads are not automatically included in the seismic mass. The total Mass DL should be increased to account for partition weight as required by the code for seismic loads.

Why do the Roof and Floor live loads both use a 1.6 factor in LRFD design?

The Ram Steel Gravity Beam and Column modules do not yet include user specified load combinations. The load combinations are hard coded into the program based on the selected code.  Since the load factors on combinations of Dead + Roof + Live loads can vary depending on the live load type or magnitude we took the conservative approach of treating all the live loads with the same load factor. There is an enhancement logged (#120493) to change this so that the more exact code combinations can be used. 

Why are my Roof Live loads ignored in the design?

RAM Structural System currently considers Snow OR Roof LL, but not both at the same time. In RAM Manager under Criteria - Members loads there is a toggle to select which the program should consider. Set the toggle to “Consider snow loads, Ignore roof live loads” when snow loads are modeled.

Note: Live Reducible, Unreducible and Storage type loads are always considered, it is only the Live - Roof type loads that are excluded when the option to consider snow loads is turned on.

Are my snow loads automatically added to the building weight for seismic load determination?

No, the program only uses the assigned Mass Dead Loads plus whatever self-mass options are turned on under RAM Manager - Criteria - Self weight when determining the total building mass or weight used in Seismic load determination (and in P-Delta calculations). The user should increase the Mass DL of applied surface loads to account for the weight of the snow load (or a percentage of the weight as required.

Note, the provided templates for load combinations do correctly consider snow load acting simultaneously with Dead, Live and Seismic loads, however.

This also applicable to Storage Live Loads, even if the magnitude entered for the Storage Live load is large (e.g. > 125 psf) no portion of the storage live load is automatically considered in the seismic mass. The user must increase the Mass DL (or manually alter the masses in Ram Frame) when part of a storage live load needs to be added to the seismic mass.

How can I apply a drift snow load?

Within the snow loads, only the top load counts. Since only the top snow load counts, the drift snow load should typically taper down from the max value to the flat-roof snow load as a minimum. The program gives a warning when any portion of the sloping plane of snow load is 0 or less magnitude.

In general, it’s best to define snow drift loads with M1 and M2 set to the highest value, and M3 set to the flat roof level. Then the loads can be applied in rectangular or trapezoidal areas as required. In the image below, the total snow load on the left is 50 psf tapering down to 30 psf on the right. This would be used in conjunction with a flat roof snow load of 30 psf applied first to the whole roof.

See Also

[[RAM Steel Beam Pattern Loading]]

RAMSS Seismic Loads FAQ

Tags: analysis, FAQs, RAM Structural System, Partition, load, Support Solutions, Dead, RAM Steel, Snow

RAM Connection Support Solutions

$
0
0
Current Revision posted to RAM | STAAD Wiki by Seth Guthrie on 12/14/2021 9:26:35 PM

The TechNotes and FAQs in this section cover various topics that pertain to RAM Connection. Use the navigation tree on the left to browse or the popular links below.

  • [[Known issues in Ram Connection 11]]

Installation and Licensing

Technical

 

Tags: RAM Connection, index, Support Solutions

Creating a foundation model in STAAD Foundation Advanced by using the data from a STAAD.Pro model

$
0
0
Revision 1 posted to RAM | STAAD Wiki by Kris Sathia on 12/15/2021 11:35:37 AM

This article explains the procedure for creating and designing foundations in Staad Foundation Advanced using the results from a STAAD.Pro superstructure model.

Two methods are available:

Method 1)

From STAAD.Pro, after the analysis is done successfully, click on Foundation Design, and follow the prompts. Once the SFA window is launched,

Once the data is comes into SFA, create a job and proceed in the manner you are familiar with. Make sure that the load cases that were brought in are properly categorized into Service and Ultimate.

Method 2)

a) Make sure that the STAAD.Pro model from which you want to transfer the data into STAAD Foundation Advanced is successfully analysed. Then, close down SFA (meaning, exit the program). This is an important step. If the file is open in STAAD.Pro, SFA will not be able to import the data.

b) Start SFA. Do not open any model (existing or New). Click on Import STAAD.Pro. Provide the file name of the STAAD model from step 1. Once the data is imported, create a job and proceed as usual. Make sure that the load cases that were imported are properly categorized into Service and Ultimate.

RAM SS v17.03 Release Notes

$
0
0
Current Revision posted to RAM | STAAD Wiki by Allen Adams on 12/16/2021 12:11:47 AM

RAM Structural System CONNECT Edition Version 17.03 SES Release Notes 

Anticipated Release Date: Q1 2022 

This document contains important information regarding changes to the RAM Structural System. It is important that all users are aware of these changes. Please distribute these Release Notes and make them available to all users of the RAM Structural System. 

Installation Instructions: 

If you have enabled the CONNECTION Client, you will automatically be notified of the newest version and will be able to update through that service by simply selecting the update command. Otherwise, this version can be found on the Bentley Software Fulfilment web page by logging into CONNECT Center and selecting the Software Downloads icon. Search for “RAM Structural System” and select the latest version. 

Important Notices:  

This version automatically converts databases created in previous versions to the new database format. Note that a backup file is created automatically when a database is converted; the name of the database is the same, with “Orig” and the version number appended to the name. The file has an extension of “.zip” and is located in the same directory as the original database. 

The previous steel tables and load combination templates supplied with the program will be replaced with new tables and templates of the same name. If you have customized any Master or Design tables or load combination templates supplied with the program without changing the file names, those file names should be renamed from the original RAM table names prior to installation to prevent your changes from being lost. 

Tutorial:  

Except for minor corrections, the Tutorial Manual has not been updated but is still valid. The appearance of some parts of the program in this version may differ from that shown in the Tutorial. 

Bentley CONNECT and Product Licensing FAQ: 

Appendix A at the end of these Notes contains important information on the features and capabilities provided to you through Bentley CONNECT, and for important information on configuring Bentley CONNECT Licensing. These were first implemented in RAM Structural System v16.00. If you have not already done so, you are urged to configure your licensing thresholds so that warnings are given if you are attempting to launch the program that would result in an overuse. 

Appendix B at the end of these Notes contains a description of features available in the RAM Structural System to help prevent inadvertent use of unlicensed modules. Refer to that document for more information. Note that with CONNECT Licensing, warning messages are given in the event there is no license available, so it generally isn’t necessary now to block modules using that feature. Note: At some point in the future this feature will be removed since it is redundant. To provide protection against inadvertent overuse of licenses, license threshold limits should be set as explained in Appendix A. 

Beginning with RAM Structural System V17.00 the licensing was changed; the licenses on the individual modules (e.g., RAM Steel, RAM Concrete, RAM Frame, RAM Foundation) were consolidated into a single package, RAM Structural System. See Appendix C at the end of these Notes for more information on this license consolidation. 

Security Risk Advisory: 

Not applicable to this release. Every effort is made to ensure that there are no security risks in the software. There are no known security issues, no issues were addressed in this version.

New Features and Enhancements: 

For details on these new features and enhancements, refer to the manual .pdf files available from the Help menu in each module or from the Manuals folder on your hard drive. 

ISM and iTwin Analytical Synchronizer 

The ISM features have been renamed, reconfigured and moved out of the File menu and are now included under the Bentley Cloud Services menu: Bentley Cloud Services – iTwin Services. When this command is invoked, the panel on the right side of the RAM Manager screen will display the Synchronize to File commands. To create a new iTwin or to update an existing iTwin, select the Push to file command (this is the same as the old File – ISM – Create ISM Repository and File – ISM – Update ISM Repository commands). To create a new RAM Structural System model or to update an existing RAM Structural System model from an iTwin, select the Pull from file command (this is the same as the old File – ISM – New From ISM Repository and File – ISM – Update From ISM Repository commands). The Structural Synchronizer is now the iTwin Analytical Synchronizer. Defaults used in creation of the iTwin model for the iTwin Analytical Synchronizer can be found in the File – iTwin Analytical Synchronizer Defaults command.  

These organizational changes have been made to provide for some powerful new capabilities that will soon be made available, including the ability to Synchronize iTwin models to and from the Cloud rather than to a local drive and a Design Review that allows you to share the model in a web browser, mark up and add comments, and view key analytical and design results. Watch for the announcement of this expanded feature. 

ACI 318-19 

The requirements of ACI 318-19 have been implemented in the Concrete and Foundation modules. Notable changes include revised shear strength equations, requirements for higher reinforcement bar grades, changes to phi given in Table 21.2.2, and seismic design details for shear walls, among others. 

ACI 318 Limit on Second-Order Effects 

ACI 318-19 Section 6.2.5.3 (and ACI 318-14 Section 6.2.6) requires that, when slenderness effects cannot be neglected, the ratio of the moment including second-order effects to the moment due to first-order effects not exceed 1.4. If that occurs, the column must be resized. If either the option to Apply Magnification Factor, delta, to all columns or the option to Apply Magnification Factor, delta-s, to sway frame columns in the Analysis Criteria dialog is selected, the program now checks for this condition when designing concrete columns and, if the ratio of second-order moments to first-order moments is greater than 1.4, gives a warning that the moment magnification factor exceeds 1.4. If this warning is given, the structural framing sizes are unacceptable and must be revised. [Note: in v17.02 this warning message was sometimes erroneously given; this enhancement was a work-in-progress not intended to be visible in v17.02.] 

ACI 318 Slenderness Criteria

Previously, in the Criteria – Analysis command there was an option to Consider Column Slenderness. When this option was selected the program:

  • Applied the moment magnifier given in ACI 318-19 Section 6.6.4.5 to Nonsway members. It was not applied to Sway members.
  • Did not apply the moment magnifier given in Section 6.6.4.6 (because it was assumed that the user performed a P-delta analysis in RAM Frame, so this magnifier was not necessary).

This command has been modified; instead of the single Consider Column Slenderness option, now there are two separate options: Apply Magnification Factor, delta, to all columns and Apply Magnification Factor, delta-s, to sway frame columns.

When the option to Apply Magnification Factor, d, to all columns is selected, the program:

  • Applies the moment magnifier given in ACI 318-19 Section 6.6.4.5 to both Sway and Nonsway members.
  • Does not apply the moment magnifier given in Section 6.6.4.6 (it is assumed that the P-delta analysis in RAM Frame is performed)

When the option to Apply Magnification Factor, ds, to sway frame columns and the frames are not braced against sidesway, the program:

  • Applies the moment magnifier given in Section 6.6.4.5 if the members are designated as Nonsway.
  • Applies the moment magnifier given in Section 6.6.4.6 if the members are designated as Sway.

IBC 2021 Load Combinations 

New load combination templates have been added based on the requirements of IBC 2021. The combinations of ASCE 7-16 are mandated by IBC 2021, but IBC 2021 has some additional requirements for the factor to be applied to the snow load in allowable stress design combinations that include both snow and seismic forces. The templates provide options to generate the combinations based on either the original ASCE 7-16 requirements or as modified by IBC 2021. These new combinations are available for the Steel Standard Provisions and Steel Seismic Provisions in RAM Frame, ACI 318-19 commands in RAM Concrete and RAM Foundation, and in the soil combinations for RAM Foundation. 

Pen Colors 

The Pen Colors dialog has been enhanced to allow the Background color to be specified (previously it was always black). If a Background color is selected that is the same color as other entities, a warning will be given that those entities will not be visible. Also, for Concrete and Other columns and walls, the Outline and the Fill colors can be specified separately. 

Modeler Enhancements 

Enhancements have been made to features in the Modeler: 

  • If Slab Openings have been erroneously modeled with Slab Edges, the DataCheck now checks for that condition (it checks to see if there is a Slab Edge polygon inside of a Slab Edge polygon), and gives an error message with instructions to use the Slab Opening command. 
  • When adding Rigid Offsets to a column it was possible to add a zero-length offset by double-clicking the column, which subsequently created bad results or caused a program crash. Furthermore, the DataCheck didn’t check for zero-length rigid links. Zero-length offsets are now prevented, and the DataCheck gives a warning if any somehow occur. 
  • If a Slab Edge polygon is created such that it closes on itself (essentially creating two distinct polygons that share a single common point), incorrect loads are calculated for the supporting members. The DataCheck now checks for that condition and gives an Error that the Slab Edges create an irregular polygon, with instructions to reconfigure the framing and/or the Slab Edges so that no more than two Slab Edge segments reference that location. 
  • The Add Cantilever command allowed Extension and Stub cantilevers to be added that crossed over an adjacent column. This is now prevented. 
  • When the Story Data has been generated using the Generate command the dialog remembers the selections used in the generation, and fills in the various fields. However, if the user wanted to make a change to a single level using the Use command, the Story Label always had to be re-entered in the Use edit box, rather than automatically being filled in. Now, the Story Label edit box is always filled in with the currently selected story’s label. 

Show Member Length in Steel Beam 

The View – Show Member Lengths commands, previously only available in the Modeler, have been added to the Steel Beam module. There are options to display either the Projected lengths or the Actual lengths (which is different than Project lengths for sloping members). The lengths are displayed for beams and walls. 

AISC ASD Standard Provisions Joint Checks 

The ability to perform the Standard Provisions Joint Checks in RAM Frame – Steel – Standard Provisions Mode was disabled in V17.02 if the selected Code was AISC 360-05 ASD, AISC 360-10 ASD, or AISC 360-16 ASD. when it was discovered that the program was using ASD load combination forces, but was using LRFD design checks, which was unconservative. This has now been corrected, and the AISC ASD joint check capabilities are once again available. 

Transverse Reinforcement 

In the Steel Beam module, for Eurocode and BS 5950 composite beam design, the Reports – Transverse Reinforcement command creates a report that lists all of the beams that require more transverse reinforcement than is indicated by the user as the typical reinforcement, listing the beam size, the number of studs if composite, the deck sheeting condition at the beam (continuous or discontinuous), and the total Asv required. This command has been enhanced; it now highlights all beams that have been included in that report so that they can easily be located. Use the View – Show Designs command to show the sizes, and then use View/Update or the Assign – Beam Size command to change beam sizes if desired. A Show Beams with Transverse Reinforcement Check Warnings button has been added to the tool bar to invoke this command. Select this button again to turn off the highlighting. 

Panel Zone 

Explicit panel zone elements can be assigned to the beam-column joints in RAM Frame using the Assign – Columns – Panel Zone command. This is applicable to joints of steel, concrete, or any material members. The panel zone stiffness can be either assigned a specific value, or in the case of steel framing it can be automatically calculated (see the RAM Frame Manual for details). With HSS columns the panel zone stiffness can be calculated in the strong and weak axes. This panel zone element provides a more accurate analytical model, rather than trying to approximate the influence of the panel zone through the use of Rigid End Zones. Typically, Rigid End Zones should not be specified when panel zone elements are assigned. 

Construction Sequence Assignment Display 

When members have been assigned a Construction Stage for Construction Sequence Analysis, the Stage number can be displayed using the View – Members command. Previously if a member had not been assigned a Construction Stage, nothing was displayed for that member, making it hard to identify which members had not been assigned. Now “None” is displayed for those members. 

DuraFuse Enhancements 

Working with and at the request of the engineers at DuraFuse Frames, some enhancements have been made to the implementation of the DuraFuse moment frame connection in RAM Frame: 

  • The thickness of the coverplate is now rounded to standard plate thicknesses rather than to 1/16” increments. 
  • There has been some loosening of the rules dictating the allowable difference between the column width and the beam width that can be accommodated by the connection. This allows for a greater mix of beam and column sizes. A warning is given if beam flange copes are required to accommodate the plates. 
  • The calculation of the panel zone stiffness has been refined for some configurations. 

DXF Beam Schedule Color/Layer Options 

The Concrete Beam Schedule DXF drawing options have been enhanced to include a distinct Color Number and Layer Name for Ties/Stirrups, and it makes better use of the Color and Layer options for other parts of that drawing, giving the user more control over the format of the DXF drawing. 

Error Corrections: 

Some program errors have been corrected for this version. Corrections made to graphics, reports, Modeler functions, program crashes, etc., that were considered minor are not listed here. The noteworthy error corrections are listed here in order to notify you that they have been corrected or to assist you in determining the impact of those errors on previous designs. These errors were generally obscure and uncommon, affecting only a very small percentage of models, or had no impact on the results. The errors, when they occurred, were generally quite obvious. However, if there is any question, it may be advisable to reanalyze previous models to determine the impact, if any. In each case the error only occurred for the precise conditions indicated. Those errors that may have resulted in un-conservative designs are shown with an asterisk. We know these errors are disruptive, we apologize for any inconvenience this may cause. 

DXF 

CONCRETE BEAM CROSS-SECTION: In the Concrete Beam Schedule, when the cross-section of rectangular beams was drawn, one corner was drawn in the wrong location. 

Effect: Distorted drawing of the cross-section. 

SHEAR WALL OUTLINE: In some cases, the shear wall outline was drawn incorrectly in the DXF output, with lines drawn to an extraneous point in a radial pattern. 

Effect: Incorrect DXF output.  

ELEVATION LABEL: The top-most story label was missing from the Elevation DXF. 

Effect: Missing label. 

FLOOR FRAMING GAP SCALE: In the floor framing DXF the gap between the beam end and the girder, and the gap between the beam end and the column, was not scaled correctly. The program was treating the specified value as if it were a model space dimension rather than a paper space dimension, which was inconsistent with other dimensions. 

Effect: No visible gaps were drawn. Note: If you have made a change to your default value to account for this, you may need to change it back, otherwise the gaps will be very large. 

Data Extractor 

REACTIONS ON STUB CANTILEVERS REVERSED*: When exporting the reactions on stub cantilevers using the Data Extractor, the reactions were reported backwards: the right reaction was reported in the left reaction column and vice versa.  

Effect: Incorrect stub cantilever beam reactions were reported. 

Manager 

SAVE AS ARCHIVE: The Durafuse .dfz file was not being included when archive files were created. 

Effect: DuraFuse data was lost when the file was archived with the File – Save as Archive command.  

GRAVITY LOADS ON LATERAL MEMBERS REPORT: The Gravity Loads on Lateral Members report lists the gravity loads applied to lateral members. In the case of a Gravity column supported by a transfer girder that was a Frame beam, the applied gravity loads reported for the Frame columns that supported that Frame beam were initially incorrect. However, after the analysis was performed in RAM Frame, the values were corrected and the report listed the correct values. 

Effect: The reported column forces may not have been correct for the case of a Gravity column supported by a Frame beam. 

Gravity Loads 

INCORRECT REACTIONS FOR SLOPING BEAMS*: In the initial gravity load distribution analysis, Dead Load reactions from sloping beams were calculated incorrectly when applied as a point load to the supporting member; the Dead Load point load values were larger than they should have been, by the inverse of the cosine of the slope angle (the correction for the slope was being applied twice). 

Effect: The Dead Load from reactions of sloping beams was incorrect for the supporting members, including beams, columns, and foundations. The values were greater than they should have been, so the error was conservative unless the member or footing design was (or should have been) controlled by uplift. The error, when it occurred, was small unless the slope was very large. This error may have impacted gravity beam and column design, Frame analysis and design, foundations, and the reactions and point loads listed in the Data Extractor. Note that for the analysis of the Frames in RAM Frame, the Dead Loads on Frame members the loads were corrected and the error did not occur if the beam self-weight option had been selected (or was the default) and a Design All was performed in the Steel Beam module, in which case the analysis results in RAM Frame were correct. 

Steel Beam 

SLOPING MEMBER LOADS*: If a beam framed into a sloping beam and if the option in the Manager to automatically include Beam self-weight in the determination of Dead Loads had been selected, the reaction from the beam supported by the sloping beam was unnecessarily transformed (the reaction had already been transformed and didn’t need to be done again) into the sloping beam’s local axis when the beams were designed during a Design All, resulting in incorrect design Dead Load point loads on the sloping beam. 

Effect: Incorrect Dead Load used in the design; point loads reduced by the cosine of the beam slope angle. 

ABSOLUTE DEFLECTION LIMITS WARNINGS*: Deflection limit failure warnings were not given in View/Update and during Design All if a composite beam failed a user-specified "delta" deflection limit for the precomposite Construction Dead Load deflection case, or if a noncomposite beam failed a user-specified "delta" deflection limit for the Dead Load or Live Load deflection cases. 

Effect: Failures to satisfy the "L/d" deflection limits were always correctly reported, and Reports, Design Color display, and View/Update Demand/Capacity Ratio all correctly indicated when the beam failed either the "L/d" or "delta" deflection limits, but on-screen failure warnings were not displayed when the beam failed the "delta" deflection limit for the precomposite Construction Dead Load deflection case for composite beams, or for the Dead Load or Live Load deflection cases for noncomposite beams. 

MOMENT CAPACITY OF ASYMMETRIC I-SHAPED MEMBERS: In the calculation of the moment capacity of asymmetric I-shaped members in Section F4 of AISC 360-16, the reported moment capacity was erroneous when Iyc/Iy was greater than 0.23 (the program always used Rpc = 1.0 even when a larger value was permitted). 

Effect: The program conservatively used a Rpc = 1.0 in the determination of the moment capacity. 

BUILT-UP BOX SHAPES: The reported capacities of built-up box sections with slender elements designed according to AISC 360-05/10 Section F7 were incorrect. 

Effect: Built-up box sections with slender elements designed according to AISC 360-05/10 reported incorrect capacities and consequently an incorrect interaction ratio when the design was governed by the limit states of Flange and Web Local Buckling. 

SINGLY SYMMETRIC I-SECTIONS AND CHANNELS: For singly symmetric I-Sections and Channels with unequal flanges designed according to AISC 360-05/10, the reported bending capacity was conservative if Flange Local Buckling governed the design and the smaller of the unequal flanges was the compression flange. 

Effect: When Flange Local Buckling of AISC 360-05 /10 governed the design of singly symmetric I-Sections and Channels with unequal flanges, the reported bending capacity of the governing section was conservative. 

DEFLECTION LIMIT – SHORED COMPOSITE BEAM: The Dead Load deflection limit for shored composite beams listed in the Gravity Beam Design report was incorrect. 

Effect: The design of shored composite beams was correctly performed but the report listed an incorrect Dead Load deflection limit. Report error only. 

DEFLECTION LIMIT – NEGATIVE TOTAL DEFLECTION:  The Negative Total deflection limit for the cantilever deflection of composite beams listed in the Gravity Beam Design report was incorrect. 

Effect: Composite beams with cantilevers were correctly designed but the report listed incorrect limits for the Negative Total Deflection for the cantilevers.  

EXPORT TO RAM SBEAM: On some machines, the export to RAM SBeam stopped working, an Error message was given: "This feature requires RAM SBeam Version 4.0 or Higher to be installed". 

Effect: While the standalone version of RAM SBeam continued to work, the user could not export from Steel Beam to RAM SBeam. 

Note: RAM SBeam v7.0 must be installed to complete this fix. 

CAN/CSA S16 WWF SECTIONS: The table of steel shapes for Canada, RAMCAN.TAB, includes welded wide-flange (WWF) shapes. Due to a flawed symmetry test in the program, these WWF sections may have erroneously been determined to be asymmetric sections, and subsequently designed using the moment capacity equations applicable to asymmetric I-shapes. 

Effect: The moment capacities of WWF shapes, which are symmetric, may have been erroneously (and conservatively) calculated using the requirements for asymmetric sections. 

Steel Column 

RAMUK COLUMN TABLE: Some Trial Group headers were missing from the RAMUK.COL table. 

Effect: Some sizes were in the wrong trial group, potentially resulting in columns from different groups being designed in the same column stack. For example, the UB305x127 sizes were included with the UB305x102 sizes, and the UB254x146 sizes were included with the UB254x102 sizes. Note that these are Beam sections, so any problem would only occur if the Beam sizes are being used for Columns, and note that the designs were correct, but the size selections may have resulted in adjacent columns in the column stack that didn’t have similar flange widths. 

EUROCODE BASEPLATE DESIGN: Some baseplates designed according to Eurocode could not be optimized. 

Effect: While optimizing baseplates designed according to Eurocode, some columns baseplates could not be optimized due to an incorrect test of plate bending stresses to capacity. Baseplates that would have otherwise passed designs were listed as failing. 

BUILT-UP BOX SHAPES: The reported capacities of built-up box sections with slender elements designed according to AISC 360-05/10 Section F7 were incorrect. 

Effect: Built-up box sections with slender elements designed according to AISC 360-05/10 reported incorrect capacities and consequently an incorrect interaction ratio when the design was governed by the limit states of Flange and Web Local Buckling. 

IS800 SLENDER SECTIONS: Messages for slender column sections per IS800 were not correctly displayed in the View/Update dialog box and the detailed Gravity Column Design report. 

Effect: Columns were correctly designed but messaging for slender columns encountered during design were not reported and users were unable to determine the nature of design failure. The View Update dialog box and detailed reports should have reported the column as slender. 

DOUBLY SYMMETRIC I-SECTION - TENSION ONLY LOADS: For doubly symmetric I-Sections subject only to tension loads and designed according to AISC 360, the interaction section of the design report showed an incorrect value of Cb. 

Effect: Report error only. The designs of doubly symmetric I-Sections under tension loading were correctly performed using the correct Cb, but the report listed an incorrect value of Cb. 

Concrete Beam 

BS 8110 REQUIRED REINFORCEMENT: In View/Update and on the Concrete Beam Design report for BS 8110 the value of AsReq was listed as 0.0 for beam in frozen beam lines. 

Effect:  AsReq not reported. 

Concrete Column 

COMBINATION MISSING IN TEXT FILE: The text for the Controlling Load Combination for the Transvers Reinforcement was missing when the Concrete Column Design report was output to a Text File. 

Effect: Report error only, Controlling Load Combination text was missing from the text file. 

TEXT FILE FORMATTING: When outputting to Text (.csv), the headings on the Concrete Column Design Summary report were missing some commas. 

Effect: When the file was read into Excel the headings didn’t align in the columns with the values. 

Concrete Wall 

MINIMUM HORIZONTAL WALL REINFORCING*: The minimum reinforcement of walls was calculated based on the parameters of vertical section cuts for horizontal reinforcing and of horizontal section cuts for vertical reinforcement, so if there was no horizontal section cut the minimum vertical reinforcement was not checked, or if there was no vertical section cut the minimum horizontal reinforcement was not checked. 

Effect: When section cuts were only in a single direction, the program only checked the minimum reinforcement for the direction perpendicular to the section cut, ignoring the reinforcement check in the other direction. Note: An approximate calculation based on the wall height and unit length is now performed when walls have section cuts in only one direction. However, when a wall might have different vertical reinforcement along its length, the user should create at least one horizontal section cut. 

ORDINARY STRUCTURAL WALLS: ACI 318-14 Section 18.10.6.5(a) (and analogous clause in ACI 318-11) apply to Special structural walls. However, an incorrect warning "Max Vert Bar Spacing per 18.10.6.5(a) at Reinforcing Zone is exceeded" was given when manual reinforcement was assigned on an Ordinary concrete wall and the c limit is exceeded. 

Effect: A message applicable only to Special structural walls may have been given even if the wall was an Ordinary structural wall. 

SHEAR WALLS WITHOUT SPECIAL BOUNDARY ELEMENTS*: ACI 318-14 Section 18.10.6.5(a) (and analogous clause in ACI 318-11) requires transverse reinforcement for boundaries not governed by 18.10.6.2 when the longitudinal reinforcement ratio exceeds 400/fy. However, no investigation of  this transverse reinforcement requirement was performed, which may have led to the under-design of the boundaries of walls subject to these criteria. 

Effect: Potentially insufficient transverse reinforcement when the requirements of ACI 318-14 Section 18.10.6.5(a) were applicable. 

BOUNDARY ELEMENTS ASSIGNED AS HINGES: Models with merged load cases could not successfully design boundary elements if the section cut had been assigned to be a Hinge (which invokes the Code requirements pertaining to plastic hinge formation, for example the ACI 318 Chapter 18 special boundary element checks). This message was erroneously given in View/Update: "Boundary element extents have not been evaluated for the selected Section Cut". 

Effect: Only when there were merged load cases, no wall design could be obtained. 

Frame - Analysis 

TORSIONAL IRREGULARITY IN DRIFT REPORT*: If the two drift values used in the calculation of Max/Min or Max/Ave in the Torsional Irregularity section of the Drift report were both negative, the values listed for Max/Min and Max/Ave may not have been correct. 

Effect: Incorrect Torsional Irregularity values reported. Note that this is rare, it only occurs if the load case applies the forces in the negative direction. 

TORSIONAL IRREGULARITY IN DRIFT REPORT*: If the two drift values used in the calculation of Max/Min or Max/Ave in the Torsional Irregularity section of the Drift report were of opposite sign, the values listed for Max/Min and Max/Ave may not have been correct. 

Effect: Incorrect Torsional Irregularity values reported. Note that this is rare, it only occurs if the torsional component of the drift is greater than the translational component. 

TORSIONAL IRREGULARITY IN DRIFT REPORT: A value of 0.0 for the minimum drift value used in the calculation of Max/Min or for the average drift value used in the calculation of Max/Ave in the Torsional Irregularity section of the Drift report could have resulted in a divide by zero. 

Effect: Likelihood was very small, but there was a potential for program crash or garbage values listed on the report. If those values are very close to 0.0, the program now lists 99.999 for Max/Min or Max/Ave. 

YIELD-LINK STIFFNESS*: The AISC Direct Analysis Method requires that a 0.8 factor be applied to all stiffnesses, and a tau_b factor be applied to flexural stiffnesses. These should be applied to the Yield-Link spring, but were not. 

Effect: This stiffness reduction does not need to be applied when investigating drift, so the drift values were correct, but it does need to be applied when investigating strength, so the design forces may have been less than they should have been (likely small impact, since the reduction was correctly applied to the beams and columns). 

WIND AND SEISMIC LOAD CASES CORRUPTED: If a Story was deleted in the Story Data command, and then that Story was added again with a new set of data, the wind and seismic load case data may have become corrupted, causing the program to crash. The same problem could occur if a diaphragm was deleted and then added again in a layout type. 

Effect: Program crash. 

MOMENT ON WALL DUE TO ECCENTRIC BEAM REACTION*: If a Wall Eccentricity has been assigned to a wall in the Modeler, and a beam frames into the wall, the program applies to the wall both a vertical reaction and an eccentric moment due to that reaction acting the assigned distance from the centerline of wall. The reaction was applied at the correct location (at the node where the beam framed in), but it erroneously applied the moment to the wall end nodes rather than at the node where the beam framed in. 

Effect: Moments due to eccentric beam reactions on walls were applied in the wrong locations. 

USER-DEFINED WIND LOADS ON SEMIRIGID DIAPHRAGM*: The program distributes user-defined wind loads along diaphragm edges. During the process of this distribution, to validate the correctness of the procedure used by the program the program verifies that the sum of distributed loads is equal to the total user-defined load, and it verifies that the moments created by the distributed loads is equal to moment due to user-defined load (usually calculated at mid-length of edges).  Occasionally for very complicated slab edge configurations the values may vary; if the sum of the distributed loads or moments does not equal those from the user-defined values, the program reports the difference as unbalanced load (or moment). This was all being done correctly, except that when such an unbalanced load or moment was found for a diaphragm, the program failed to apply the calculated loads to that diaphragm. 

Effect: Some user-defined wind loads assigned to semirigid diaphragms may not have been applied. 

INCORRECT DEFLECTED SHAPE FOR SERVICE OR STRENGTH COMBINATIONS*: In Load Combination mode, if the model included Strength or Service combinations, the program incorrectly displayed the deflected shape of the combination of the analyzed load case results rather than the deflected shape of that analyzed load combination (note that the program directly analyzes Strength and Service combinations). 

Effect: Incorrect deflected shape was displayed for Strength and Service combinations. 

ABORTED ANALYSIS WITH TILT-UP WALLS: The program erroneously displayed a “zero-length element found” error message and aborted the analysis if all of the following conditions existed: 1) there was a tilt-up wall with a gap joint, 2) a lateral beam framed into the gap joint, and 3) the option "Include Rigid Link at Fixed Beam-to-Wall Locations" was selected. 

Effect: The error was displayed and the analysis aborted. 

STORY SHEAR AND WALL GROUP REPORTS ERRORS*: If the model included a tilt-up walls with gaps and the tilt-up wall had an opening at its base next to the gap, the program reported incorrect shear values in the Building Story Shear, Frame Story Shear, and Wall Group Forces reports; the reports missed shear from the tilt-up wall. 

Effect: Report error. Incorrect shear values were reported in the reports indicated, for the conditions indicated. 

STRESS AND INTERNAL FORCE CONTOUR DISPLAY: If the model was analyzed and then subsequently the mesh criteria was changed and the model remeshed, the display of the Stresses and Internal Forces was incorrect unless RAM Frame was closed and then reopened. 

Effect: Incorrect display of stresses and forces. 

WALL AND DIAPHRAGM STRESSES AND INTERNAL FORCES: Wall and diaphragm stresses and internal forces displayed on screen or printed in the Stress and Internal Force Summary reports were not correct if the model was in SI or Metrics units.   

Effect: Incorrect stress/internal force values were displayed or reported for walls and diaphragms in SI or Metric units. 

Frame – Drift 

JOINT PARTICIPATION IN DRIFT MODULE: If the model included an assigned panel-zone element at a joint, the effects of shear in the joint were double-counted – by including both that of the assigned panel zoned element and that of the traditional joint – in the reported joint participation value in the Drift module. 

Effect: Reported joint displacement participation value was greater than it should have been. 

Frame – Shear Wall Forces 

WALL SECTION FORCES REPORT: The Wall Section Forces report in the Shear Wall Forces module had two errors: In the CRITERIA section of the report the Scale Factor listed for P-delta was always that associated with the Mass option even if the Use Gravity Loads option had been selected, and the reported diaphragm type was always listed as Rigid even when other diaphragm types were used at various levels. 

Effect: Report error only. 

Frame – Steel Standard Provisions 

AISC 360 COMBINED FLEXURE AND TENSION: The reported equation reference for members designed according to AISC 360 subjected to flexure and tension was incorrect. 

Effect: Members subjected to flexure and tension and checked using AISC 360 were correctly designed according to provisions of section H1.2, but the reported controlling design incorrectly referenced H1.3. This was report related only. 

HYBRID YIELD-LINK JOINT*: The Standard Provisions Joint View Update dialog crashed if a joint was selected that had a Yield-Link connection on one side and a non Yield-Link connection on the other side. 

Effect: All joints assigned Yield-Link connections were correctly designed, but an investigation of joints with a Yield-Link connection on one side and a non Yield-Link connection on the other side resulted in a crash in the Standard Provisions Joint View/Update dialog. 

BRBF FY-MAX AND FY-MIN: Design of Buckling Restrained Braces assigned Fy-max and Fy-min using SI Units was incorrect. 

Effect: Due to a units conversion error, Buckling Restrained Braces assigned Fy-max and Fy-min using SI Units were not designed correctly.  

SINGLY SYMMETRIC I-SECTIONS AND CHANNELS: For singly symmetric I-Sections and Channels with unequal flanges designed according to AISC 360-05/10, the reported bending capacity was conservative if Flange Local Buckling governed the design and the smaller of the unequal flanges was the compression flange. 

Effect: When Flange Local Buckling of AISC 360-05 /10 governed the design of singly symmetric I-Sections and Channels with unequal flanges, the reported bending capacity of the governing section was conservative. 

MOMENT CAPACITY OF ASYMMETRIC I-SHAPED MEMBERS: In the calculation of the moment capacity of asymmetric I-shaped members in Section F4 of AISC 360-16, the reported moment capacity was erroneous when Iyc/Iy was greater than 0.23 (the program always used Rpc = 1.0 even when a larger value was permitted). 

Effect: The program conservatively used a Rpc = 1.0 in the determination of the moment capacity. 

BUILT-UP BOX SHAPES: The reported capacities of built-up box sections with slender elements designed according to AISC 360-05/10 Section F7 were incorrect. 

Effect: Built-up box sections with slender elements designed according to AISC 360-05/10 reported incorrect capacities and consequently an incorrect interaction ratio when the design was governed by the limit states of Flange and Web Local Buckling. 

Frame – Steel Seismic Provisions 

SCBF AND BRBF COLUMN CAPACITY LOAD DESIGN*: For SCBF frames, columns are required by AISC 341 Sections F2.3(a) and (b) to be designed for loads based on the expected strength of the braces, and for BRBF frames, columns are required by AISC 341 Section F4.3 to be designed for loads based on the adjusted strength of the braces. The program performs this analysis and design. However, in the case of frames in which the columns were oriented with their weak axis in the plane of the frame, those capacity forces from braces that framed down from the level above onto the top right side of the column were not applied. 

Effect: For columns rotated as described above, those columns were designed for loads that did not include the capacity load from braces that framed down from the level above to the top right side of the column. Loads from braces that framed down from the level above onto the top left side of the column were correctly applied; loads from braces that framed up to the top of the column from below on either side were correctly applied. This error did not occur if the columns were oriented with their strong axis in the plane of the frame.  

STRONG COLUMN – WEAK BEAM EXCEPTION*: AISC 341-16 Section E3.4a requires that SMF columns be stronger than the beams, with an Exception given in Section E3.4a(a) and (b). The program determines if an SMF column is a top story column as specified in Section E3.4a(a)(1) when determining if the Exception is applicable. Erroneously, if the option to Apply all one and two story exceptions was selected in the Criteria – Codes command in Steel - Seismic Provisions mode, all columns may have been granted the Exception, not just those at the top story. That option was not intended to be applied to this Exception.

Effect: The Strong Column – Weak Beam check may not have been performed if the option to Apply all one and two story exceptions was selected.

WUF-W AND OTHER CONNECTIONS: If the option to Use AISC 358 was selected for Moment Frames in the Criteria – Codes command and if the beam had not been assigned to be an RBS (i.e., the connection was a WUF-W or some other generic moment connection type), the seismic design moment at the face of the column was erroneously determined using AISC 358 Section 5.8 Eq. (5.8-6) for RBS beams, resulting in the beam failing the test against the moment capacity. 

Effect: Beam connections designated as WUF-W or OTHER that would have otherwise passed designs were erroneously failed.   

Foundation 

BS 8110 AND CP65 SHEAR STRENGTH*: The enhanced shear strength allowed by BS 8110 Section 3.4.5.8 was erroneously applied to the shear strength of spread footings. 

Effect: The spread footing may have had inadequate depth if shear controlled. 

RAM DataAccess 

REACTIONS FROM STUB CANTILEVERS MISSING*: When accessing reactions on columns at a story using the CGravityLoads_DAMan::GetStoryGravityReactOnCol method in RAM DataAccess, reactions from stub cantilevers were not included. 

Effect: Incorrect column reaction was exported when the column supported a stub cantilever. 

 

Appendix A

Bentley CONNECT Licensing – Subscription Entitlement Service

Bentley CONNECT Licensing has now been renamed Subscription Entitlement Service. CONNECT Licensing was first implemented in the RAM Structural in v16.00. This licensing monitors current usage and, if an attempt is made to use a program or module for which there is no available license, the program will give a warning. Important information is given in the v16.00 Release Notes.

More information on CONNECT Licensing / Subscription Entitlement Service can be found at:

https://www.bentley.com/en/subscription-services-portal/subscription-entitlement-service

User and Administrator instructions can be found here:

https://communities.bentley.com/products/licensing/w/licensing__wiki/37813/subscription-entitlement-service-formerly-connect-licensing

and a short guide has been posted here:

https://communities.bentley.com/products/ram-staad/m/structural_analysis_and_design_gallery/273502

CONNECT License / Subscription Entitlement Service requires all users to sign-in in order to use any Bentley programs. If you do not already have a Bentley ID, go to http://www.bentley.com/profile and select the Sign Up Now link.

NOTE: If you haven’t done so already, before using any version 16.0 or newer, the person at your company that has the role of Administrator for the Bentley products must configure the license so that it gives the overuse warnings. Otherwise, by default no warnings will be given. Instructions can be found here:

https://communities.bentley.com/products/licensing/w/licensing__wiki/38540/1---subscription-entitlement-service-for-administrators-getting-started

Review all of the information, but in particular, note the section on Entitlement Management, and in that document note the instructions on License Alerting. Generally, for License Alerting you will want to Enable Alerts, and then input the number of licenses that you own for the particular product.

CONNECT Licensing / Subscription Entitlement Service is revolutionary. It warns you against incidental overuse of the program, but when you have a temporary heavier work load it allows you to intentionally use more licenses than you own, at a fraction of the cost of purchasing an additional copy. Subscription Entitlement Service gives you the information you need to control usage and make those decisions.

Bentley CONNECT

In addition to providing the overuse warning described above, Bentley CONNECT offers several benefits. Listed here are two key features:

CONNECT Center

When you sign in to your Bentley account you now have easy access to CONNECT Center. This personalized portal gives you access to Usage reports, site configuration information, downloads, and Learning information on webinars, seminars and events, and includes a transcript listing the Bentley courses that you have completed. Your personal portal also lists your recent projects with a portal into analytics on that project. CONNECT Center can be accessed by selecting the Bentley Cloud Services – CONNECT Center command or by selecting the Sign In command in the upper right corner of the RAM Manager screen.

CONNECTED Projects

All of Bentley’s CONNECT Edition programs, including RAM Structural System, allow models to be associated with a project. Multiple models, from any of the Bentley products, can be associated with a given project. This simplifies the process of keeping track of work done for a project, and will enable analytics to be performed and reported for the project.

A ProjectWise Projects portal enables you and your project teams to see project details required to evaluate team activity and understand project performance.

  • View project activity by site, application and user
  • Gain insights into the users who are working on your projects and their effort
  • Register and manage your CONNECTED Projects
  • Access ProjectWise Connection Services including ProjectWise Project Sharing, ProjectWise Project Performance Dashboards and ProjectWise Issue Resolution Administration

When a model is Saved in this version the program will ask for a Project to which the file is to be associated. Projects can be registered (created) from your Personal Portal, or from the Assign Project dialog by selecting the + Register Project command.

Appendix B

Product Licensing FAQ – RAM Structural System: Blocking Use of Modules and Programs

VERSIONS 17.00 AND NEWER

The RAM Structural System contains links to three related Bentley products, RAM SBeam, RAM Concept and RAM Connection, providing design interoperability. Each of those programs have their own licenses. It is possible for a client to have licenses for some programs but not for the others. Because of the ease with which these programs can be invoked, a method of restricting the use of each has been incorporated in order to prevent unwanted or inadvertent usage by an unsuspecting user from being logged against the licenses that the company actually owns.

Note that if you have installed CONNECT versions of these programs and have correctly set up the warnings on entitlements you will receive a warning if overuse is about to occur; you may find it advantageous to rely on these warnings rather than blocking their use entirely as described below.

RAM SBeam is invoked using the Process – Export to SBeam command in the Steel Beam module. RAM Concept and RAM Connection are invoked using the tool bar buttons on the left of the RAM Manager screen:

or by using the Model or Design menu items:

If RAM SBeam, RAM Concept, or RAM Connection are not installed, they will not be available to be selected.

In RAM Manager, the Tools – Manage License Restrictions command opens the following dialog:

This provides a mechanism for the user to prevent a program from being inadvertently executed. When the RAM Structural System is first installed all of these options are selected. It is important therefore to execute this command and deselect any links for which the user wants to restrict access.

To prevent a program link from being executed, deselect that item.

If a link is deselected here and that link is subsequently invoked, the following dialog appears:

If Allow is selected the program will open, and usage will be logged. If Cancel is selected the program will not open and no usage will be logged. Settings opens the previous command, allowing the user to modify the selections of the allowed programs.

Note that there is also a link to Bentley’s ProjectWise for project management. It is available through the File – ProjectWise command. Its use is not restricted through the Tools – Manage License Restrictions command described above. It should only be invoked if you have a license for it.

VERSIONS 14.07 Through 16.01

The RAM Structural System is composed of several modules, each of which has their own license. The program also contains links to two related Bentley products, RAM Concept and RAM Connection, providing design interoperability, as well as a link to Bentley’s ProjectWise for project management. Each of those programs also have their own licenses. It is possible to have several licenses of one or more modules, and few or no licenses of other modules. Because of the ease with which these various modules and programs can be invoked, a method of restricting the use of each has been incorporated in order to prevent unwanted or inadvertent usage by an unsuspecting user from being logged against the licenses that the company actually owns.

These modules are invoked using the tool bar buttons on the left of the RAM Manager screen:

 

or by using the Model or Design menu items:

If RAM Concept or RAM Connection are not installed, they will not be available to be selected.

There is no license associated with RAM Manager, so no usage data is logged against it, but usage data is logged against each of the other modules as soon as they are invoked.

In RAM Manager, the Tools – Manage License Restrictions command opens the following dialog:

This provides a mechanism for the user to prevent a module from being inadvertently executed. When the program is first installed all of these options are selected. It is important therefore to execute this command and deselect any modules or links for which the user wants to restrict access.

To prevent a module or program link from being executed, deselect that item.

If a module is deselected here and that module or link is subsequently invoked, the following dialog appears:

If Allow is selected the module will open, and usage will be logged. If Cancel is selected the module will not open and no usage will be logged. Settings opens the previous command, allowing the user to modify the selections of the allowed modules.

Note that there is also a link to Bentley’s ProjectWise for project management. It is available through the File – ProjectWise command. Its use is not restricted through the Tools – Manage License Restrictions command described above. It should only be invoked if you have a license for it.

VERSIONS 14.06 AND EARLIER

Versions prior to V14.07 lacked the ability to manage these license restrictions, restrictions could only be achieved by deleting the module from the installation Prog directory. If you are using an earlier version and want to prevent use of a module, delete the file(s) listed here for the module to be prevented:

RAM Steel:

RamBeam.exe, RAMColumn.dll

RAM Concrete:

RAMConcAnalysis.dll, RAMConcreteBeam.dll, RAMConcreteColumn.dll, RAMConcreteShearWall.dll

RAM Frame Analysis:

RAMFrameAnalysis.dll

RAM Foundation:

RamFoundation.exe

Appendix C

License Consolidation

Beginning with RAM Structural System V17.00 the licensing has changed; the licenses on the individual modules (e.g., RAM Steel, RAM Concrete, RAM Frame, RAM Foundation) have been consolidated into a single package, RAM Structural System. See the RAM Structural System V17.00 Release Notes on Bentley Communities for a more detailed description and important instructions:

https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/43199/ram-ss-v17-00-release-notes

For more complete and updated information, go to the RAM Structural System V17.0 License Consolidation wiki on Bentley Communities:

https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/43302/ram-structural-system-v17-0-license-consolidation.

 

Appendix D

Datacheck Enhancements – Technology Preview

In order to include the new Datacheck checks, you must modify the ramis.ini file (located in the C:\ProgramData\Bentley\Engineering\RAM Structural System directory) to include the following section:

[Testing]

DatacheckOffset = 1

DatacheckOffsetLowerTol = 0.00000001

DatacheckOffsetUpperTol = 1.0

DatacheckHorizVert = 1

DatacheckHorizVertLowerTol = 0.000000000001

DatacheckHorizVertUpperTol = 0.001

DatacheckOffMember = 1

DatacheckOffMemberLowerTol = 0.0001

DatacheckOffMemberUpperTol = 0.1

DatacheckOffMemberLowerAngleTol = 0.1

DatacheckOffMemberUpperAngleTol = 4.0

This section should be added after the [Tip] section. Use Notepad or other simple text editor (not Word, for example) when editing the ramis.ini file.

These variables associated with the checks are defined below.

Members slightly offset from grids. If a member is very nearly but not exactly attached to a nearby grid intersection, it is often an indication that the member is not attached to the intended snap point, but rather to a nearby point. This is generally not a problem, such conditions are allowed, but when the other framing around this member use the correct grid point, in very rare cases this condition can cause gravity loads to be incorrectly distributed or cause the analysis to terminate.

DatacheckOffset:          Set equal to 1 to include this check, set equal to 0 to exclude this check.

DatacheckOffsetLowerTol:  Distance (inches), the lower tolerance on the check.

DatacheckOffsetUpperTol:  Distance (inches), the upper tolerance on the check.

Members very nearly horizontal or vertical. If a beam or wall is very nearly but not exactly horizontal in plan, it is often an indication that the member end is not attached to the intended snap point, but rather to a nearby point. Same for a member that is very nearly but not exactly vertical in plan. This is generally not a problem, such conditions are allowed, and in some cases intended, but when the other framing around this member use the correct snap point, in very rare cases this condition can cause gravity loads to be incorrectly distributed or cause the analysis to terminate.

DatacheckHorizVert:           Set equal to 1 to include this check, set equal to 0 to exclude this check.

DatacheckHorizVertLowerTol:   Difference (in.) between the coordinate at each end of beam or wall, the lower tolerance on the check.

DatacheckHorizVertUpperTol:   Difference (in.) between the coordinate at each end of beam or wall, the upper tolerance on the check.

Deck or Load polygon edges misaligned with member. If the edge of a Deck or Surface Load polygon very nearly but not exactly coincides with a beam or wall, it is often an indication that the polygon vertex was not attached to the intended snap point, but rather to a nearby snap point. Alternatively, it may be an indication that the beam or wall was not modeled exactly as intended. Deck polygon edges should coincide precisely with beams and walls; surface load polygons are not required to coincide with beams and walls, but this condition, in which the edge very slightly diverges from the beam or wall, should be avoided. The program generally deals with this problem correctly, but in rare cases this condition can cause composite properties to be incorrectly assigned to a beam, cause gravity loads to be incorrectly distributed, or cause the analysis to terminate.

DatacheckOffMember:                Set equal to 1 to include this check, set equal to 0 to exclude this check.

DatacheckOffMemberLowerTol:        Distance (in.) between the polygon edge and the member; the lower tolerance on the check.

DatacheckOffMemberUpperTol:        Distance (in.) between the polygon edge and the member; the upper tolerance on the check.

DatacheckOffMemberLowerAngleTol:   When the polygon edge and the member are skewed with respect to each other, the angle between the two; the lower tolerance on the check.

DatacheckOffMemberUpperAngleTol:   When the polygon edge and the member are skewed with respect to each other, the angle between the two; the upper tolerance on the check.

The program analysis can handle some degree of imperfection; it is not necessary that member and polygon coordinates are exactly precise, but very small offsets generally indicate unintended modeling conditions. There appears to be a range of distances and angles that sometimes are problematic for the analysis to perform correctly. The goal of this Technology Preview is to determine the proper range of values necessary to catch the critical conditions without producing an excessive amount of unnecessary warnings. For the lower tolerance value, the goal is to find the largest acceptable value; if the value is too small it will result in unnecessary warnings, if the value is too large it will miss conditions that might be a problem. For the upper tolerance value, the goal is to find the smallest acceptable value; if the value is too large it will result in unnecessary warnings, if the value is too small it will miss conditions that might be a problem.

If you find that the Datacheck is giving numerous unnecessary warnings, try tightening the tolerances; if it is missing problem conditions, try loosening the tolerances. Please report to us your experience with this feature so that we can finalize it and make it a regular part of the Datacheck.

Check this site periodically, the recommended values may change as testing and usage indicate better values.

Tags: v17.03, RAM Structural System, release notes, RAM

STAAD Foundation Advanced Videos

$
0
0
Current Revision posted to RAM | STAAD Wiki by Kris Sathia on 12/16/2021 8:51:41 AM

1 How it Works - Load Cases, Load Combinations, and Creating Jobs

www.youtube.com/watch

2 Column Position & Dimension, Pedestal & Anchor Bolt, and Anchor Library

www.youtube.com/watch

3 Loads for Mat Foundation

www.youtube.com/watch

4 Creating Multiple Jobs on a Single Foundation

www.youtube.com/watch

5 Difference Between Service and Ultimate Loads

www.youtube.com/watch

6 Isolated Footing Jobs

www.youtube.com/watch

7 Combined Footing Job

www.youtube.com/watch

8 Octagonal Foundation Job

www.youtube.com/watch

9 Vertical Vessel Foundation

www.youtube.com/watch

10 Vertical Vessel Foundation with Pilecap

www.youtube.com/watch

11 Heat Exchanger or Horizontal Vessel Foundation Isolated Design

www.youtube.com/watch

12 Heat Exchanger or Horizontal Vessel Foundation Combined and Strap Footing

www.youtube.com/watch

13 Tank Foundation

www.youtube.com/watch

14 Drilled or Driven Pier Foundation

www.youtube.com/watch

15 Pile Cap Foundation

www.youtube.com/watch

16 Strap Foundation

www.youtube.com/watch

17 Mat Foundations

Part 1

www.youtube.com/watch

Part 2

www.youtube.com/watch

18 Creating a foundation model in SFA by using the data from a STAAD.Pro model - Method 1

communities.bentley.com/.../Launch-SFA_5F00_3.mp4

19 Creating a foundation model in SFA by using the data from a STAAD.Pro model - Method 2

communities.bentley.com/.../Import-STAAD.Pro_5F00_1.mp4

Tags: staad foundation advanced videos, STAAD Foundation Advanced, import, video tutorials

RAM Connection CONNECT Edition V13 Update 6 (v13.6.1) Release Notes

$
0
0
Revision 1 posted to RAM | STAAD Wiki by Carlos Perez on 12/16/2021 3:12:34 PM

RAM Connection CONNECT Edition V13 Update 6 Patch 1 (v13.6.1) Release Notes – Updated December 2021

This is a patch release (full installer) for RAM Connection v13.6.0 release.

Resolved Issues:

  • Limcon import forces convention fixes for base plates, end plates and bolted end plates.

  • Limcon import flush end distance was not being considered. This is fixed now and end plates end distances are considered correctly.

  • AISC splice plates includes now a geometric check to verify that the plate fit inside the wide flange brace.

  • AISC transversal stiffeners demands were not being calculated properly for seismic design in a MEP for AISC Design Guide 4. This is fixed and demands are being calculated properly according to seismic frame for all connections.

  • AISC moment end plate incorrect demands for shear yielding and shear rupture for axial only load case. These are now fixed and the demands are calculated according the specification.

  • AISC horizontal column-beam-Brace connection titles were inverted when column was defined as transversal. This is fixed now and titles are shown properly for any column configuration.

Structural WorkSuite Hub CONNECT Edition (12.0.0) Release Notes

$
0
0
Current Revision posted to RAM | STAAD Wiki by Wentao Zhang on 12/19/2021 10:15:48 PM

Release Date:  17th June 2020

Release Name: Structural WorkSuite Hub CONNECT Edition

Release Version: 12.00.00.04

To achieve better alignment with naming convention for other Bentley products and offerings. Both our Structural offering (formerly known as Structural Enterprise) and the Hub to consume it (formerly known as Structural Enterprise Hub) has been renamed. See below table.

Old NameNew Name
Software LicenseStructural EnterpriseStructural Enterprise WorkSuite
HubStructural Enterprise HubStructural WorkSuite Hub

Download Instructions

Structural WorkSuite Hub can be downloaded at the link here, or from Bentley Cloud Services. After signing into the CONNECTION Center, select Software Downloads under My Support. Once on the Software Fulfillment page, the installer can be located by performing a search on “Structural WorkSuite Hub”.

For all users (including existing users), Structural WorkSuite Hub will require a one-time download from either of the above methods. After which, update to Structural WorkSuite Hub itself would be presented as an update option within Structural WorkSuite Hub itself.

 

Subscription Entitlement Service (SES) 

This product version utilizes Subscription Entitlement Service, which is not supported by SELECT activation key(s). SES is a free service, featuring new behavior to enhance your organization’s user administration and security with mandatory user sign-in via CONNECTION Client to access the application. If you are already signed in to the CONNECTION Client, you have met this prerequisite. If you have not, please refer to the Administrator's Resource Center and/or contact your administrator for assistance in the registration and sign-in process. 

Structural WorkSuite Hub Release Notes

$
0
0
Current Revision posted to RAM | STAAD Wiki by Wentao Zhang on 12/19/2021 10:17:00 PM

This section holds release notes to Structural WorkSuite Hub.

(40238 False)

Structural WorkSuite Hub CONNECT Edition (12.1.0) Release Notes

$
0
0
Current Revision posted to RAM | STAAD Wiki by Wentao Zhang on 12/19/2021 10:29:56 PM

Release Date:  COMING SOON

Release Name: Structural WorkSuite Hub CONNECT Edition

Release Version: 12.01.00.04

This version of Structural WorkSuite Hub contains general stability fixes as well as access to Ideas Portal and Product News and Announcement Feeds accessible.

Ideas Portal

Allow you (the user) to provide us valuable feedback that will steer Structural WorkSuite Hubs future development. Feel free to submit an idea by clicking on "Add a New Idea"

Product News and Announcement Feeds

Allows you to quickly stay up to day with recent product news and announcements.Check regularly to watch Coffee Corners, Tips and Tricks, on-demand recordings and more!

Download Instructions

Structural WorkSuite Hub can be downloaded at the link here, or from Bentley Cloud Services. After signing into the CONNECTION Center, select Software Downloads under My Support. Once on the Software Fulfillment page, the installer can be located by performing a search on “Structural WorkSuite Hub”.

For all users (including existing users), Structural WorkSuite Hub will require a one-time download from either of the above methods. After which, update to Structural WorkSuite Hub itself would be presented as an update option within Structural WorkSuite Hub itself.

 

Subscription Entitlement Service (SES) 

This product version utilizes Subscription Entitlement Service, which is not supported by SELECT activation key(s). SES is a free service, featuring new behavior to enhance your organization’s user administration and security with mandatory user sign-in via CONNECTION Client to access the application. If you are already signed in to the CONNECTION Client, you have met this prerequisite. If you have not, please refer to the Administrator's Resource Center and/or contact your administrator for assistance in the registration and sign-in process. 

iTwin Analytical Synchronizer CONNECT Edition V12 Update 1 Patch 1

$
0
0
Current Revision posted to RAM | STAAD Wiki by Wentao Zhang on 12/20/2021 6:36:15 PM

Release Date: (COMING SOON) 20th December 2021

Release Name: iTwin Analytical Synchronizer CONNECT Edition V12 Update 1 -  Patch 1

Release Version: 12.01.01.01

This is a Patch Release and addresses:

  • Updated Security Components to adhere to Security Requirements

 

Download Instructions

After signing into the CONNECTION Center, select Software Downloads under My Services. Once on the Software Fulfillment page, the installer can be located by performing a search on “iTwin Analytical Synchronizer”. Direct Software Downloads link.

Subscription Entitlement Service (SES) 

This product version utilizes Subscription Entitlement Service, which is not supported by SELECT activation key(s). SES is a free service, featuring new behavior to enhance your organization’s user administration and security with mandatory user sign-in via CONNECTION Client to access the application. If you are already signed in to the CONNECTION Client, you have met this prerequisite. If you have not, please refer to the Administrator's Resource Center and/or contact your administrator for assistance in the registration and sign-in process. 

RAM Connection Support Solutions

$
0
0
Current Revision posted to RAM | STAAD Wiki by Seth Guthrie on 12/20/2021 9:19:56 PM

The TechNotes and FAQs in this section cover various topics that pertain to RAM Connection. Use the navigation tree on the left to browse or the popular links below.

  • [[Known issues in Ram Connection 11]]

Installation and Licensing

Technical

 

Tags: RAM Connection, index, Support Solutions

Crash Opening or Saving on PC with Dell Backup

$
0
0
Current Revision posted to RAM | STAAD Wiki by Seth Guthrie on 12/21/2021 6:17:38 PM
 Applies To 
 Product:Ram Concept 
First Affected Version:6.04.00.06
 Found in Version:6.04.00.06
Released in Version:-
Environment:Windows 7 x64; Windows 10
 Area: File; Installation
 Issue #:796452

Problem Description

In Ram Concept version 06.04.00.006 x64 (or later), on certain Dell PCs typically running Windows 7 x64 or Windows 10 x64, an error, "Concept for Windows has stopped working," can occur when attempting to open a file using the File - Open menu or folder icon. A similar error can occur when trying to save a file that is successfully opened through a file browser or direct link. 

On other machines running Windows 10, the error occurs as soon as the program is started and indicates "Program Error (Unknown Exception: in program startup) Contact Support"

Or the program may simply close abruptly without any message. 

Reason

As described in this thread, Dell’s Backup and Recovery software, version 1.8.1.71, will crash any 64-bit Qt5 application whenever a file dialog is opened, and in some cases causes the program to crash on startup. 

Solution

Upgrading DBaR to version 1.9.2.8 or later should fix the issue. Alternatively, if it's not being used, Dell's Backup and Recovery system can be uninstalled. 

See Also

[[An Error Has Occurred when Opening or Saving]]

[[RAM Concept x64 Crash due to RSS News Feed]]

Tags: installation, RAM Concept, File, crash, known issue, First 6.04

Distorted graphics in STAAD.Pro on Dell Alienware computers

$
0
0
Revision 6 posted to RAM | STAAD Wiki by Sye on 12/21/2021 8:02:01 PM

  
 Applies To 
  
 Product(s):STAAD.Pro
 Version(s):All
 Environment: N/A
 Area: GUI
 Subarea: N/A
 Original Author:Dhiman Basu, Software Development Support Group
  

It has been observed that on certain computers use of STAAD.Pro rendering of the icons in the ribbons and workflows is distorted. Investigation on this has identified the cause to be related to DELL machines which runs AWCC Service that is AlienWare Command Center. 

The solution to this issue : 

  1. Ensure STAAD.Pro is closed. 
  2. In Windows explorer, navigate to the folder C:\ProgramData\A-Volute\DellInc.AlienwareSoundCenter\Modules\ScheduledModules\Configurator
  3. Open the any text editor (like notepad, notepad++) in administrator mode and open the BlackApps.dat
  4. Add the following list of executables at the end of the BlackApps.dat

    SXP.exe

    Bentley.Staad.AutoLoadCombRuleManager.exe

    Bentley.Staad.Editor.exe

    Bentley.Staad.exe

    Bentley.Staad.Licensing.Configuration.exe

    Bentley.Staad.ScriptEditor.exe

    Bentley.Staad.UnitConverter.exe

    Calculator.exe

    SectionDBManager.exe

  5. Save the BlackApps.dat file 
  6. Open Task Manager and go to 'Services' and search for 'AWCCService' - Right click and 'Restart'
  7. Launch STAAD.Pro and the problem should be fixed

Similar issues may occur with software that uses similar technology to STAAD.Pro as these applications may benefit from similar style solution by adding the executable in the exclusion list as above.

See Also

Icons in the side panel of RAM Connection are distorted

References

Tags: Distorted Graphics in STAAD.Pro, STAAD.Pro Graphical Issue, Icons are distorted

Icons in the side panel are distorted

$
0
0
Revision 5 posted to RAM | STAAD Wiki by Sye on 12/21/2021 8:07:13 PM

 Applies To 
 Product(s):RAM Connection, RAM Elements
 Version(s):N/A
 Environment: N/A
 Area: General
 Original Author:Bentley Technical Support Group

Problem Description

It has been observed that on few machines using RAM Connection, while hovering the mouse on icons in the side panel, they look distorted.

Reason

Investigation on this has identified the cause to be related to DELL machines which runs AWCC Service that is AlienWare Command Center. 

Steps to Resolve

  1. Exit out from RAM Connection. 
  2. Open Windows explorer, navigate to the folder C:\ProgramData\A-Volute\DellInc.AlienwareSoundCenter\Modules\ScheduledModules\Configurator,
  3. Add the following list of executables at the end of the BlackApps.dat.
    RAMConnection.exe
    RAMConnStandalone.exe
  4. Save the BlackApps.dat file .
  5. Open Task Manager and go to 'Services' and search for 'AWCCService' - Right click and 'Restart'.
  6. Launch RAM Connection and it should run fine.

Similar issues may occur with RAM Elements; adding the executable (RAMElements.exe) in the exclusion list as above will correct the problem.

P.S. The folder ProgramData from step 2 above, may be not visible to you; you should check with your IT group on that.

Notes:

Any updates to the ‘AlienWare Command Center’ or AWCC service can cause the above changes made to the BlackApps.dat file to get wiped out, in which case, the graphics problems would resurface. In such cases, one would have to repeat the steps 1 to 6 listed above.

See Also

Distorted graphics in STAAD.Pro on Dell Alienware computers

Structural Product TechNotes And FAQs

Tags: RAM Elements, Graphical distortion in RAM Conncetion, graphics, RAM Connection, Icons are distorted

RAM Elements Foundation [FAQ]

$
0
0
Current Revision posted to RAM | STAAD Wiki by Seth Guthrie on 12/21/2021 10:38:39 PM
 Product(s):RAM Elements
 Version(s):10.00 or later
 Area: Modeling; Analysis; Design

 For combined footings, why do I get a warning for rigid entity length to width ratio?

The foundation module uses the provisions of ACI 318 for rigid foundations.  The foundation is determined to be rigid by length to width ratio values.  The warning acknowledges that this is a flexible foundation.  The engineer will need to either change the footing dimensions to be within guidelines OR do some additional checks based on ACI flexible foundation design.

The following equations are used to determine rigid footing classification:

Why can't I assign a spread footing?

In order to assign a spread footing to a model the following conditions must be met: 

  • A model with complete analysis including
  • At least one each of Service (or RC-Service) and Design (or RC-Design) type combinations
  • The user must select a node or nodes with a support (or spring).

Additionally, in order to assign a continuous footing, the user must select exactly two nodes with supports. The program does not strictly enforce the requirement that the nodes have the same elevation (Y coordinate), but that is the best practice since the continuous footing design assumes a flat foundation.

See Also

Ram Elements Modules

Tags: RAM Elements, footing, FAQs, SELECTservices, Combined Footing, foundation

Validation Documents

$
0
0
Current Revision posted to RAM | STAAD Wiki by Nidhi Valia on 12/22/2021 8:12:42 AM

The validation documents / examples within this section are used to validate the accuracy of the design performed of Columns, Beams, Shear-walls, Isolated Foundations, Pile-caps.

Below is short description of the design philosophy considered in RCDC:

RCDC is a RCC design software that supports designing of various elements of a RC structure like:

  1. Column and Shear Wall Design
  2. Beam Design
  3. Isolated Footings (Pad, Sloped and Step) Design
  4. Pile Cap with Pile arrangements of 1 pile to 6 piles can be Designed.
  5. Slab (Regular conventional slabs) Design.
  6. Water Tank Structure Design

 

Short description on what is covered in the design part of each element and the validation along with code reference is provided in the validation documents available as per below list.

  • Column and Shear Walls Design Specifics:
    • Story Sway/Non-sway condition is determined and further used for the effective length factor calculation.
    • Minimum Eccentricity check is performed.
    • Slenderness check is performed and for slender column the magnified slenderness moment is also calculated based upon code guidelines.
    • Biaxial bending design by plotting the 3D Interaction curve is performed.
    • Shear check is performed and for ductile columns the additional shear from beams is also considered while finalizing the Final Shear Force.
    • Ductile Links design as per code guideline is performed.
    • Crack-width check as per user requirement and settings is performed.
    • Joint check for Ductile columns is performed.
  • Beam Design Specifics:
    • Beams are designed and detailed based on its type whether Simply supported or Continuous or Cantilever.
    • Flexure + Torsion design and Shear + Torsion design is performed zone wise in left mid and right zones.
    • Skin reinforcement or the Side face reinforcement is provided depending upon different criteria mentioned in different design codes.
    • Crack-width check as per user requirement and settings is performed.
  • Footing Design Specifics:
    • Type of footing – Pad, Step, Sloped or On-raft can be assigned and further the Footings are sized by performing the Maximum and Minimum pressure check.
    • The sizing is checked for the Stability checks like Buoyancy, Sliding and Overturning.
    • Depending upon the Design method selected (Average Pressure / Maximum Pressure / Factored SBC), Flexure design is performed, and reinforcement configuration is finalized.
    • One way shear as well as Punching shear check is performed, and the required depth of the footing is finalized. If there is restriction on the maximum depth only then RCDC will go ahead and provide the Stirrups if required.
    • The load transfer check is performed and wherever the footing size if insufficient to transfer the load, provision is made to provide the required Dowel bars.
  • Pile cap Design Specifics:
    • RCDC will determine the Pile configuration as per the Pile capacities entered by user.
    • The Pile cap is designed considering various checks like Pile overloading check, Pile group overloading check considering user settings made pre-design.
    • Flexure design is performed for the Pile cap using the Beam-theory.
    • One-way shear check is performed, and depth is finalized for shear requirement.
  • Slab Design Specifics:
    • Slabs in RCDC are detected to be enclosed between the polygon formed by Beam frame.
    • Dead load and live load intensities needs to be provided in RCDC for performing the design.
    • The Type of Slab and the Type of Span is determined as per Design code Guidelines.
    • Slab is further designed for flexure and checked for shear and deflection.
  • Water Tank Design Specifics:
    • For this module in RCDC, the Tank Walls and the Tank Slabs gets designed and also if any miscellaneous structure with a beam column geometry can be designed.
    • Tank Walls and the Tank Slabs are designed for Flexure and Shear and further the check for Crack width and Drying and Thermal Shrinkage can be selected to be performed.
    • Multiple zones are created to handle Design as well as Detailing of the Vertical and Horizontal reinforcement in the Tank Walls.
    • The Vertical reinforcement is Curtailed also depending upon the Wall geometry and Reinforcement requirement along the height of the Wall.

The validation documents are available for below mentioned design codes;

  1. American Concrete Design Code ACI 318  (FPS Units)
  2. American Concrete Design Code ACI 318M  (Metric Units)
  3. Australian Concrete Design Code AS 3600 - 2018
  4. Euro Code - BS EN 1992 - 1 - 1 - 2004
  5. Indian Code - IS 456 + IS 13920 - 2016
Tags: RCDC, Validation Documents
Viewing all 8748 articles
Browse latest View live