  1. How can I get my RISA model into STAAD.Pro ?
  2. I do not see the option import/export using StrucLink module.

1. How can I get my RISA model into STAAD.Pro ?

There is no way to directly get a RISA model into STAAD.Pro. You may check whether RISA can export in the following formats, both of which can be imported by STAAD.Pro.

1.  CIS/2
2.  3D DXF

Out of these, the CIS/2 is the best option as it lets you transfer not only the wireframe but other member information like Member properties, Material properties, Member orientation, Member end conditions like Releases, Support conditions, Loading information

3D DXF transfer will let you transfer the wireframe only.

These import options in STAAD.Pro can be accessed from within the top menu File > Import

2. I do not see the option import/export using StrucLink under User Tools section.

There could be few reasons behind this.

1) You must not have installed the StrucLink while installing STAAD.Pro.

2) You may have installed StrckLinkStrucLink sperately, but there is a version mismatch.

To fix it, uninstall STAAD.Pro & any version of StrckLinkStrucLink you may have from Control Panel (Add/Remove Program or Programs and Feathures)

Reinstall STAAD.Pro, for Windows Vista/7/8 operating system, right-click on the .msi./.exe file and select the option "Run as administrator" (though you are logged in as administrator). If you run the file as the local administrator only, the program will not be installed properly. "Run as administrator" option is a must; you may need help from your IT personnel. Ensure that the check box next to the "Install companion product" is checked.

 

Once installation is done successfully, you should see the following options under "User Tools" section.

See Also

XXXXXXX(Add more links as needed for other relevant Be Communities content.)XXXXXXX


STAAD.Pro Postprocessing [FAQ]

$
0
0
Current Revision posted to Structural Analysis and Design Wiki by Sye on 9/5/2013 11:33:23 PM

STAAD.Pro Postprocessing [FAQ]

FAQs,ResultDiagram,STAADPro,selectservices

  
 Applies To 
  
 Product(s):STAAD.Pro
 Version(s):All
 Environment: N/A
 Area: Postprocessing
 Subarea: N/A
 Original Author:Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

  1. How do I display the deflection diagram and the displacement values on that diagram?
  2. After running the analysis, I go to the View menu, select Tables | Node Displacements, and select the load cases for which I want to see the values. The values are displayed in inch units. I want them in "cms" units. Changing the units using Tools | Set Current Unit doesn't seem to make a difference.
  3. I want to print out a picture which consists of a truss I have modeled with the STAAD. I want the output forces labeled right on each member. This is very similar to what would be put on to a plan sheet. Can STAAD do this or must I print out a report to get these forces?
  4. When I annotate beam moments on my diagrams, I can't seem to 1) change the font by adjusting the Beam Labels option and 2) turn off the unit being written on every single number.
  5. Why are my annotations for maximum bending moment or shear values not showing up in the post-processing mode?
  6. If I have a moment vector along the local positive Z axis does it have a twisting action going to the right along the positive direction of the axis?
  7. What are the sign conventions for moments in a 3-D structure?
  8. After performing the analysis, I enter the post-processing mode to view the member end force values. I click on the Beam page on the left side of the screen and see the values listed on the tables on the right hand side. Unfortunately, the moment values are in kip-inch units, even though my current units are set to feet and pounds. What do I have to do to get the values to show up in pound-feet units in the tables?
  9. What is the purpose of the Beam - Graphs page on the left side of the screen?
  10. How do I display the bending moment diagram and the values on that diagram, or shear forces or Axial forces?
  11. When I take a picture, it prints on the top half of a 8-1/2 x 11 size page. How can I take pictures that fill the page?
  12. How to insert a company logo into STAAD.Pro report?
  13. CanIgetSTAAD.Protoreportthetorsionstress?

 

1. How do I display the deflection diagram and the displacement values on that diagram?

The first step to viewing these results is to perform the analysis of the model successfully. Select Analyze from the Staad.Pro top menu bar followed by the Analysis option.

A dialog box by the name Select Analysis Engine will appear. Click on the Run Analysis button of this dialog box. After the analysis of the file is completed, click on the Done button.

The next step is to go to the Post Processing mode to view the deflection values graphically. To enter into the Post Processing mode, select Mode from the top menu bar and select Post Processing. Remember that if your analysis is not successfully completed (for reasons such as errors in your input data), you will not be able to access the Post Processing mode.

By default, the deflection diagram always opens up in the post processing screen of Staad.Pro.

From the top menu bar, choose Results - View value. Under Ranges, choose All. (The All button means the deflection diagram will be annotated for all nodes.)

Under the Node tab, you will see the options Global X, Global Y, Global Z and Resultant. Make the appropriate choice. Click on the Annotate button. Then click on the close button.

If you would like to see the diagram annotated for a different load case, select that load case from the load selection box.

2. After running the analysis, I go to the View menu, select Tables | Node Displacements, and select the load cases for which I want to see the values. The values are displayed in inch units. I want them in "cms" units. Changing the units using Tools | Set Current Unit doesn't seem to make a difference.

The unit system in which results are displayed on the tables is set using the facilities available under the View - Options menu. These are known as the display units. To set the display units for the node displacements, please do the following :

In the View menu, select Options - Structure units. In the category called Displacement, select the units you desire and click on OK.

3. I want to print out a picture which consists of a truss I have modeled with the STAAD. I want the output forces labeled right on each member. This is very similar to what would be put on to a plan sheet. Can STAAD do this or must I print out a report to get these forces?

First, you have to ask STAAD to Annotate the drawing with the axial forces. For this, please go to the post processing mode after you have analyzed the structure.

Click on the "Beam" tab on the left side and then click on the sub-tab labeled "Forces."

Click the right mouse button on the screen and select "Structure Diagrams."

From the "Loads and Results" tab, click on "Axial" under the "Beam Forces" heading.

Uncheck the "bending zz" box and click "Apply" followed by "OK."

Maximize the screen and then go to the "Results" pull down menu and select "View Value..."

Click on the "Beam Results" tab and then check the box under the "Axial" heading labeled "Ends."

Click "Annotate" and then "Close."

The axial loading values should be displayed on your screen.

4. When I annotate beam moments on my diagrams, I can't seem to 1) change the font by adjusting the Beam Labels option and 2) turn off the unit being written on every single number.

Annotation labels, although applied to beams, nodes, plates and solids, are not altered by the associated options (i.e View | Options | Beam Labels). In order to change the display of the annotations, go to View | Options from the main menu and choose the Annotation tab. To remove the display of the units for each annotation, simply choose the option "123.4" instead of "123.4 kN" under the Style list box in the Annotation tab. This will write the unit in the bottom right-hand corner of the screen for force, length and moment. If the units are not shown, go to View | Structure Diagrams and choose the Labels tab. Check on the option "Show Diagram Info" under the General box.

5. Why are my annotations for maximum bending moment or shear values not showing up in the post-processing mode?

In order to see the annotation (from Results->View Value in the post-processing mode) for a particular force or moment, the corresponding diagram must be on. For example, if one was to select maximum bending under the Beam Results tab, the bending moment diagram must be on (either MX, MY and/or MZ). Also, under the Ranges tab, make sure that the "None" option is not selected. Obviously, this would not annotate anything if it were selected. As a final note, once the annotations are visible, the size and font can be changed from the Annotation tab under View->Options in the main menu.

6. If I have a moment vector along the local positive Z axis does it have a twisting action going to the right along the positive direction of the axis?

If a member is drawn with its longitudinal axis (local-X) from left to right, and the local Z axis coming out of the page towards you, a positive MZ would cause tension on the top fiber, and a negative MZ would cause tension on the bottom fiber.

7. What are the sign conventions for moments in a 3-D structure?

The sign conventions are as follows:

Axial (FX) : Positive = Along local X axis, Negative = Opposite to local X
axis
Shear-Y (FY) : Positive = Along local Y axis, Negative = Opposite to local Y
axis
Shear-Z (FZ) : Positive = Along local Z axis, Negative = Opposite to local Z
axis

Torsion (MX) : Positive = Along local X axis, Negative = Opposite to local X
axis
Moment-Y (MY) : Positive = Along local Y axis, Negative = Opposite to local
Y axis
Moment-Z (MZ) : Positive = Along local Z axis, Negative = Opposite to local
Z axis

For axial forces,

Positive at the start node indicates compression at the start node.
Positive at the end node indicates tension at the end node.

Negative at the start node indicates tension at the start node.
Negative at the end node indicates compression at the end node.

8. After performing the analysis, I enter the post-processing mode to view the member end force values. I click on the Beam page on the left side of the screen and see the values listed on the tables on the right hand side. Unfortunately, the moment values are in kip-inch units, even though my current units are set to feet and pounds. What do I have to do to get the values to show up in pound-feet units in the tables?

The unit system in which results are displayed on the tables is set using the facilities available under the View - Options menu. These are known as the display units. To set the display units for the bending moments and torsional moments, please do the following :

In the View menu, select Options - Force units. In the category called Moment, select the units you desire and click on OK.

9. What is the purpose of the Beam - Graphs page on the left side of the screen?

This is another way to display the bending, shear and axial force diagrams on the screen.

In the post processing mode, select the Beam page from the left side of the screen. Then select graphs.

The right side portion of the screen will display the Bending diagram (MZ), shear diagram (FY) and the axial force diagram (FX) with values. In the drawing area, if you select a member by clicking on it, MZ, FY and FX of
that member will be displayed on the right hand side. To display the diagrams of another member, select that member.

10. How do I display the bending moment diagram and the values on that diagram, or shear forces or Axial forces?

First you must Analyze the file. Select Analyze from the Staad.Pro top menu bar. Select the Analysis option. After this, click on Run Analysis at the bottom of the small window dialog box.

After the analysis of the file is completed, click on the Done button.

Next, we go to the Post Processing mode to view the forces and results graphically.

To enter into the Post Processing mode, select Mode from the top menu bar and select Post Processing. Remember that if your analysis is not complete, you will not be able to access the Post Processing mode.

By default, the deflection diagram always opens up in the post processing screen of Staad.Pro.

To view the Bending Moment Diagrams, select the Beam page from the left side. From the top menu bar, choose Results - View value. Under Ranges, choose All. (The All button means the Bending moment diagram will be displayed for all members.)

Under the Beam Results tab, you will see the options Bending, Shear, Axial, Displacement and Stresses.
Make the appropriate choice.

Click on the Annotate button. Then click on the close button.

11. When I take a picture, it prints on the top half of a 8-1/2 x 11 size page. How can I take pictures that fill the page? 

There is no direct way to change the size of the picture from within STAAD.Pro. However here are a few options that you may find useful

Option 1

  1. Before taking a picture, please ensure that the model is
    zoomed in sufficiently so that it fills up the space within the picture border as far as possible.
  2. Take the picture and include that as part of the report using the Report Setup.
  3. Go to File > Printer Setup and change the orientation to Landscape.
  4. Go to File > Print Preview Report to check whether it looks satisfactory or not and if so, print it.


Option 2

  1. You may copy the picture by going to the menu option Edit > Copy Picture. You can then paste the picture in MSWord or Excel or Paint.
  2. Adjust the size of the picture using the tools available within these applications and take a print from there.

 

12. How to insert a company logo into STAAD.Pro report?

1. Open the start-up window of STAAD.Pro and go to the Configuration option.

2. Choose “File Options” tab and tick the “Remove Bentley Logo from Report” box. This will remove the Bentley logo    from your reports

3. Open the STAAD.Pro file. Go to the Report setup page and click on “Name and Logo” option.

4. Go to file option and choose the path where you have stored your logo. The logo should be in .bmp format.

5. Write the company name. You can orient the logo and company name by the Alignment option.

 

Note, Ram Elements, Connection and Ram Structural System have similar options. For Elements or Connection go to the upper left menu - General Configuration - Print tab. For RAM Structural System you just have to replace the logo.bmp file in the program directory with your own logo.bmp or logo.jpg file. it tends to work best when the log has roughly a 1:1 aspect ratio.

13.CanIgetSTAAD.Protoreportthetorsionstress?

STAAD.ProdoesnotreportstressduetoTorsionbuthereareacoupleofitemswhichyoumayfinduseful.

ThebeamendforcestablethatyoucangetfromPostprocessingmodeBeam>Forcespage,reportsthetorsion(MX)inabeammember.

STAADisalsoabletoaccountforstressesduetotorsionduringthedesignphase.Insteeldesignforexample,thetorsionstressesareconvertedtonormalandshearstressesandaddedtoexistingnormal/shearstressesfollowingguidelineslaidoutinAISCDesignGuide9.WhenitcomestothenewAISC360-10code,currentlythesoftwarecanaccountforthetorsionforHSSsectionsonlyalthoughworkisunderprogresstoaccountfortorsionforNon-HSSsectionstooandthisshouldbeavailableinacoupleofmonths

See Also

Product TechNotes and FAQs

Structural Product TechNotes And FAQs

External Links

Bentley Technical Support KnowledgeBase

Bentley LEARN Server

Comments or Corrections?

Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

 

RAMSS Modeling [FAQ]

$
0
0
Current Revision posted to Structural Analysis and Design Wiki by Seth Guthrie on 9/6/2013 5:49:55 PM

RAMSS Modeling [FAQ]

FAQs,RAMStructuralSystem,RAMModeler,selectservices

  
 Applies To 
  
 Product(s):RAM Structural System
 Version(s):Any
 Environment: N/A
 Area: N/A
 Subarea: N/A
 Original Author:Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

What floor-to-floor height should I enter in the story data?

Whatever story height you enter into RAM Modeler, that is where the centerline of the frame beams will fall in the finite element model and vertical braces always connect to a work point at the beam and column centerlines. This is done for simplicity in the finite element analysis.

For drift sensitive structures, using a first story height that is equal to the distance from the ground level (or foundation level) up to the top of steel - average frame beam depth / 2 is probably the most accurate modeling (see "Alternate Story El." below). But using a distance from ground level to beam top of steel (a.k.a. deck bearing) is more common practice and is conservative in most aspects (see "Common Story El." below).

ThecommonstoryapproachisalsousedwhentheRAMSS3DmodelisexportedtoISM.IntheISMmodelthebeamlocationsareestablishedrelativetothestorydatumbasedonthefollowingrules:

  • Noncompositedecktopofbeam,deckbearingatstorydatum
  • Compositedecktopofbeam,deckbearingatstorydatum
  • Concreteslabtopofslabatstorydatum

Keep in mind, story height can also affect the following calculations:

  • Calculated wind exposure (and Kz factors)
  • "h" in the vertical distribution of seismic loads calculation (wi*hi/Sum (wi*hi))
  • Overturning moment (related to lateral force times story height)
  • Unbraced length for columns
  • Slope angle and length of braces
  • Material takeoff quantities
  • And the elevation of the beams shown in the 3D view, or exported out to Revit, ISM, or dxf, which are all artificially adjusted to show all beams with top of steel at the story height.

 

Can a beam cantilever directly from a support with no back-span?

Yes, the option to create a stub cantilever or beam with a single support was added in version 14.02.  The following applies to prior versions:

In the RAM Modeler, a cantilever can only be created by extending a simple-span beam over its support. When the building requires a stub cantilever which cantilevers directly from the column, then a special modeling trick can be employed.

In order to get an accurate analysis and design of that cantilever beam, requires the use of RAM Frame. Start by modeling the column which will support this cantilever. Make that column lateral and make sure that it is supported by other lateral columns if this is not the lowest level. Next add a dummy column at the point where the cantilever stops. Make this dummy column out of “Other” material and assign it a very small “E” value (e.g. 1). Then assign that column a section size under Property table – Other column sections that is very small (e.g. 1” square).

Next model in the cantilever as a simple, lateral beam from the real column to the dummy column. At the end where this beam frames to the real column be sure to assign a fixed end condition so that moments can develop. You will also need to make sure that the column is capable of taking moment at the top.

The finished section of the model should look something like the figure below. Note – the analysis results from RAM Frame will provide an accurate design, but the gravity beam and column modules will not recognize that this dummy column is too weak to take load. Only the finite element analysis of RAM Frame is capable of that.

How can I create a sloping roof?

There are some basic limitations to what you can model with RAM Structural System, so it may not be possible to model some structures perfectly, but you can usually get close. The following guidelines should help

  • Every beam must have exactly two supports, never 1 or 3, and those supports must be on the same level type. So you can't directly model a bent beam forming a gable unless there is a support at the peak.
  • You must be able to model the structure as a flat (wedding cake) type structure first, then create the slopes by changing column (and wall) elevations.
  • Any time you have a step (two beams framing into the same support at different elevations), two levels types and two stories are required and the higher beam must be on the higher story.
  • You can raise or lower a column (or wall) using the Layout - Column - Modify elevation command and thus slope beams that connect to it. If you want to lower the column more than the story height, then you must also lower the same column on the next lower story. Think of the column like a string with beads on it at each story. As you modify the elevation you are lowering the bead, but you cannot cross another bead. In the end, the beads must be at least 0.1’ apart (more separation is preferred).

Other things to note:

  • You can have a rigid diaphragm that is sloped, but in RAM Frame this is treated as a horizontal diaphragm. We don't analyze sloped rigid diaphragms. Furthermore, if your structure is subject to trust, diaphragms should be turned off at least while investigating gravity loads. Using a sloped semi-rigid diaphragm is an alternative.
  • The gravity steel and concrete beam design will not include any effects of axial forces.

 

I modeled a roof with multiple slopes, but in the 3D view the deck is a single sloped plane shooting up.  How do I fix this?

Starting in version 14.0, the program will display the surface of the deck in 3D.

For a sloping deck to function correctly in this regard, the deck must be input using a separate polygon for each sloping surface. In other words, for a gable roof, two deck polygons should be defined, one for each side or slope of the roof.  A whole-floor application of the deck is no longer sufficient.

It is suggested to snap to the beam end points when defining these decks, since the beam end points have exact elevations which are derived from the supporting column or wall elevations. Even slight imprecision in the support elevations (i.e. warping of the deck) can cause this anomaly in 3D.

How can I model a 2 story brace, or one that skips a level?

When a brace needs to skip a level use Layout - brace - Add Special and follow the prompts at the bottom left.

 

For details on how these braces effect frame story shear reporting, please reference [[RAM Frame - Building and Frame Story Shear]].

I have a brace in 3D that does not appear in any elevation view. How can I delete it?

There are two ways to remove rogue braces that are no longer in an elevation view that can be selected.

  1. If the braces do not connect to any frame members at either end, then an integrated data check can be performed and the following message will appear: "Some Braces do not attach to Nodes. Do you want them deleted?". Click "Yes" to have them removed. Note – if the brace is connected to a lateral member at one end, but not the other, this message will not appear, so you may need to make some supporting beams or column gravity temporarily.
  2. Delete and re-enter the story data for this particular level. This will remove all braces at that level.
     

How Do I Model Grade Beams?

Although there is currently no direct way to model grade beams in RAM Structural System, they can be simulated by modeling concrete beams and designed in RAM Concrete. These basic steps produce satisfactory results for most configurations.

  1. Model a grade level that contains the concrete grade beams supported by columns. The top of the columns should be pinned and the bottom fixed.
  2. Model a slab edge on the grade beam level and assign a noncomposite deck with no selfweight. This is necessary so that there is a diaphragm present on the level in RAM Frame.
  3. Add the grade level to your story data.
  4. In RAM Frame, set the ground level to the grade level.
  5. Run the RAM Frame analysis and RAM Concrete Beam design.

By creating a rigid diaphragm at the grade level with the nodes at the grade beam - column intersections to it, translation is restrained when the ground level is set to the grade level. Therefore, no shear will exist in the column stubs. Since the top of the column stubs are pinned, no moment will be developed in the column stub below the grade beams. Spread footings or pile caps can be modeled at the column stub locations. The foundation loads will only be vertical forces.

There are a couple of important things to note. First, automatic calculation of effective length factors may be inaccurate for this procedure. No boundary condition is assumed at the lower node of the column above the grade beam level. Therefore, the G value for the lower node is a function of the column and grade beam stiffness in the direction being considered. If this is not an accurate assumption, the effective length factor should be explicitly defined. Second, don't specify a story height on the grade beam level that is too small. Using an extremely small story height is not necessary because there will be no translation of the grade beam level and only vertical forces in the stub columns. The only ramification of using a larger story height is an increased selfweight for the stub columns. If you use too small of a story height you might produce a poor mesh if lateral walls are modeled on the grade beam level.

See Also

Product TechNotes and FAQs

Structural Product TechNotes And FAQs

External Links

Bentley Technical Support KnowledgeBase

Bentley LEARN Server

Comments or Corrections?

Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

 

   

Creating custom elements in RAM Elements [TN]

$
0
0
Current Revision posted to Structural Analysis and Design Wiki by Seth Guthrie on 9/6/2013 10:08:13 PM

Creating custom elements in RAM Elements [TN]

RAMElements,TechNote,customgroups,sections,materials,connections,bolts,welds,selectservices

  
 Applies To 
  
 Product(s):RAM Elements; RAM Connection
 Version(s):V8i
 Environment: N/A
 Area: Tables
 Subarea: N/A
 Original Author:Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

Overview

RAM Elements 10.5 changes the way that custom materials, sections, connections, bolts, and welds are added to the database. These changes were necessary to permit RAM Elements to run with minimal privileges in security-conscious environments.

Creating custom Sections, Materials, Connections etc.

To create a custom material, section, connection, bolt, or weld, select the appropriate button in the Databases ribbon found on the Home menu.

Screenshot of Databases ribbon

RAM Elements includes various groups of elements organized by country. These groups are locked and new data cannot be added to these groups. So a new custom group must be created. To do this, click the New Group button in the upper right (circled in the screenshot below).

Screenshot highlighting New Group button

Give the new group a name in the dialog box that appears, e.g. "Custom" or "My Sections". Upon clicking OK, the new group will appear on screen. New elements cannot be created until a new table is added to the group. To do this, click the New Table button just below the New Group button (circled in the screenshot below).

Screenshot highlighting New Table button

Give the new table a name in the dialog box that appears, e.g. "My Pipes". Except in the case of welds, the dialog box will also require additional information such as the type. Pick the appropriate type from those available. Upon clicking OK, the new table will appear in the left column. From here, you can create a new item from scratch by clicking the New Item button (circled in the screenshot below).

Screenshot highlighting New Item button

To modify an existing item included with RAM Elements, it is recommended to make a copy in a custom group and then edit it. To do this, select an existing item in one of the groups provided with RAM Elements. Then click the Copy selected item to clipboard button (circled in the screenshot below).

Screenshot highlighting Copy button

Navigate to a custom group, select a table, and then click the Paste items from clipboard button (circled in the screenshot below). Note that the copied item must match the type of the table. Copy(1) is automatically appended to the name to prevent duplicate entries in the database.

Screenshot highlighting Paste button

Finally, edit the item by double-clicking its listing in the right pane, or click the Edit Item button on the right edge.

Noteitisalsopossibletoimportatextfiletodefineshapes,butimportingfromtheclipboardgenerallyworksbest.Onestrategyistocopydatatotheclipboard.Pastethatdataintoablankspreadsheet.Thenmanipulatethespreadsheetasnecessary,addingrows,changingvaluesetc.Thencopythemodifieddatabacktotheclipboardand finallyusethe"PasteItemsfromClipboard"buttontoaddagroupofshapesatonce.

.

Deleting custom groups

To delete a custom group, remove all items and tables from it. The empty group will be removed automatically when RAM Elements is closed.

See Also

Structural Product TechNotes and FAQs

External Links

RAM Elements product page

Comments or Corrections?

Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article in the "Comments" area below. THANK YOU!

STAAD.Pro Import/Export [FAQ]

$
0
0
Revision 9 posted to Structural Analysis and Design Wiki by AndrejLogunov on 9/9/2013 12:02:54 PM

STAAD.Pro Import/Export [FAQ]

FAQ, STAAD.Pro, export, import, SELECTsupport, Struclink, Import/Export

  
 Applies To 
  
 Product(s):STAAD.Pro
 Version(s):ALL
 Environment: N/A
 Area: Import/Export
 Subarea: 
 Original Author:Sye Chakraborty, Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

  1. How can I get my RISA model into STAAD.Pro ?
  2. I do not see the option import/export using StrucLink module.
  3. HowtoOpenaQSEFile?

1. How can I get my RISA model into STAAD.Pro ?

There is no way to directly get a RISA model into STAAD.Pro. You may check whether RISA can export in the following formats, both of which can be imported by STAAD.Pro.

1.  CIS/2
2.  3D DXF

Out of these, the CIS/2 is the best option as it lets you transfer not only the wireframe but other member information like Member properties, Material properties, Member orientation, Member end conditions like Releases, Support conditions, Loading information

3D DXF transfer will let you transfer the wireframe only.

These import options in STAAD.Pro can be accessed from within the top menu File > Import

2. I do not see the option import/export using StrucLink under User Tools section.

There could be few reasons behind this.

1) You must not have installed the StrucLink while installing STAAD.Pro.

2) You may have installed StrucLink sperately, but there is a version mismatch.

To fix it, uninstall STAAD.Pro & any version of StrucLink you may have from Control Panel (Add/Remove Program or Programs and Feathures)

Reinstall STAAD.Pro, for Windows Vista/7/8 operating system, right-click on the .msi./.exe file and select the option "Run as administrator" (though you are logged in as administrator). If you run the file as the local administrator only, the program will not be installed properly. "Run as administrator" option is a must; you may need help from your IT personnel. Ensure that the check box next to the "Install companion product" is checked.

 

Once installation is done successfully, you should see the following options under "User Tools" section.

SeeAlso

XXXXXXX(AddmorelinksasneededforotherrelevantBeCommunitiescontent.)XXXXXXX

3.HowtoOpenaQSEFile?

GotoFile>ImportandselectQSEASAoption:

STAAD.Foundation FAQs

$
0
0
Revision 10 posted to Structural Analysis and Design Wiki by Payel on 9/12/2013 12:16:45 AM

STAAD.Foundation FAQs

FAQ, SELECTsupport, STAAD.foundation, General Foundation, Pile cap, multiple column

  
 Applies To 
  
 Product(s):STAAD.foundation
 Version(s):06.00.00.11
 Environment: N/A
 Area: General Foundation
 Subarea: 
 Original Author:Sye Chakraborty, Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

Following are a list of FAQs related to STAAD.Foundation/ STAAD.Foundation Advanced

  1. I have multiple columns which are supported by a single pile cap. How can I model that in STAAD.foundation
  2. I modeled a steel structure and want to design pile cap on piles for foundation. Can I import the support reaction from STAAD.Pro. ? Can STAAD.Foundation design this entirely or does it need to be modeled in STAAD.Pro ?
  3. When I start up STAAD.foundation, I get a message "SELECT license type is not configured yet. Please run SELECT License Asistant to configure it".
  4. [[structural_analysis_and_design__wiki:/products/structural/structural_analysis___design/w/structural_analysis_and_design__wiki/8059.aspx#FAQ4|Ihaveaprobleminstaadfoundation,thematfoundationisnotworkingonlytheisolatedfootingworking.]]

1. I have multiple columns which are supported by a single pile cap. How can I model that in STAAD.foundation ?

As of now a pile cap, created in STAAD.foundation using the pile cap job type, can only support one column point. If you have multiple columns which are supported by a single pilecap, you will have to create it as a Mat Foundation job and then model the pile cap as a mat. The piles can then be specified under the mat using the Pile spring option.

 

2. I modeled a steel structure and want to design pile cap on piles for foundation. Can I import the support reaction from STAAD.Pro. ? Can STAAD.Foundation design this entirely or does it need to be modeled in STAAD.Pro ?

Support reactions from STAAD.Pro can be directly taken into STAAD.foundation using the Foundation Design tab within STAAD.Pro and then the pile cap can be designed in STAAD.foundation. For this process there is no need to model pile caps in STAAD.Pro.

If you are asking whether STAAD.Foundation can be used as a standalone application for design of pile caps, then the answer is yes. For that you have to manually enter the column locations and then enter the column reaction loads in STAAD.foundation. If you are modeling the superstructure in STAAD.Pro for analysis, then getting support reactions from STAAD.Pro would spare you the effort of defining the column points and re-entering the loads in STAAD.Foundation and so the process would be a lot faster.

3. 3. When I start up STAAD.foundation, I get a message "SELECT license type is not configured yet. Please run SELECT License Asistant to configure it".

This issue occurs in Windows Vista/7/8 machines, if STAAD.foundation program is not installed with enough administrative privileges.This prevents the registry to be set properly.

To resolve this, right-click on the shortcut for STAAD.foundation in your desktop, and select the option "Run as Administrator". This fixes the registry issue. Next time you can run the program by double-clicking on the shortcut.

To prevent this, when you install STAAD.foundation in Windows Vista/7/8 machine, right-click on the .msi/.exe file and select the option "Run as administrator". This ensures that the resistry is set propely.

4.Ihaveaprobleminstaadfoundation;thematfoundationisnotworking,onlytheisolatedfootingisworking.

PleaseinstallSTAADFoundationAdvancedV8i  inyourmachine. STAAD.foundationfromSTAAD.ProdoesnotsupportMatfoundation(assumingthatyouareusingSTAAD.ProV8iBuild#20.07.08..20orlaterversion).It
supportsonlyIsolated,combinedandPilecapmodulesingeneralmode.

 

See Also

[[Structural Product TechNotes And FAQs]]

STAAD.Foundation FAQs

$
0
0
Revision 11 posted to Structural Analysis and Design Wiki by Payel on 9/12/2013 12:19:55 AM

STAAD.Foundation FAQs

FAQ, SELECTsupport, STAAD.foundation, General Foundation, Pile cap, multiple column

  
 Applies To 
  
 Product(s):STAAD.foundation
 Version(s):06.00.00.11
 Environment: N/A
 Area: General Foundation
 Subarea: 
 Original Author:Sye Chakraborty, Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

Following are a list of FAQs related to STAAD.Foundation/ STAAD.Foundation Advanced

  1. I have multiple columns which are supported by a single pile cap. How can I model that in STAAD.foundation
  2. I modeled a steel structure and want to design pile cap on piles for foundation. Can I import the support reaction from STAAD.Pro. ? Can STAAD.Foundation design this entirely or does it need to be modeled in STAAD.Pro ?
  3. When I start up STAAD.foundation, I get a message "SELECT license type is not configured yet. Please run SELECT License Asistant to configure it".
  4. [[structural_analysis_and_design__wiki:/products/structural/structural_analysis___design/w/structural_analysis_and_design__wiki/8059.aspx#FAQ4|I
  5. I have a problem in staad foundation, the mat foundation is not working only the isolated footing working.]]working.

1. I have multiple columns which are supported by a single pile cap. How can I model that in STAAD.foundation ?

As of now a pile cap, created in STAAD.foundation using the pile cap job type, can only support one column point. If you have multiple columns which are supported by a single pilecap, you will have to create it as a Mat Foundation job and then model the pile cap as a mat. The piles can then be specified under the mat using the Pile spring option.

 

2. I modeled a steel structure and want to design pile cap on piles for foundation. Can I import the support reaction from STAAD.Pro. ? Can STAAD.Foundation design this entirely or does it need to be modeled in STAAD.Pro ?

Support reactions from STAAD.Pro can be directly taken into STAAD.foundation using the Foundation Design tab within STAAD.Pro and then the pile cap can be designed in STAAD.foundation. For this process there is no need to model pile caps in STAAD.Pro.

If you are asking whether STAAD.Foundation can be used as a standalone application for design of pile caps, then the answer is yes. For that you have to manually enter the column locations and then enter the column reaction loads in STAAD.foundation. If you are modeling the superstructure in STAAD.Pro for analysis, then getting support reactions from STAAD.Pro would spare you the effort of defining the column points and re-entering the loads in STAAD.Foundation and so the process would be a lot faster.

3. When I start up STAAD.foundation, I get a message "SELECT license type is not configured yet. Please run SELECT License Asistant to configure it".

This issue occurs in Windows Vista/7/8 machines, if STAAD.foundation program is not installed with enough administrative privileges.This prevents the registry to be set properly.

To resolve this, right-click on the shortcut for STAAD.foundation in your desktop, and select the option "Run as Administrator". This fixes the registry issue. Next time you can run the program by double-clicking on the shortcut.

To prevent this, when you install STAAD.foundation in Windows Vista/7/8 machine, right-click on the .msi/.exe file and select the option "Run as administrator". This ensures that the resistry is set propely.

4. I have a problem in staad foundation; the mat foundation is not working, only the isolated footing is working.

Please install STAAD Foundation Advanced V8i  in your machine. STAAD.foundation from STAAD.Pro does not support Mat foundation (assuming that you are using STAAD.Pro V8i Build #20.07.08..20 or later version). It
supports only Isolated, combined and Pile cap modules in general mode.

 

See Also

[[Structural Product TechNotes And FAQs]]

I have undertaken a linear static analysis and have a range of utilisations from 0.01 to 1.013. Is it possible for Staad to show utilisations within a certain range e.g UR =0.5 to UR =0.9? I am able to manually select the members from the design results ta

$
0
0
Revision 2 posted to Structural Analysis and Design Wiki by Kris Sathia on 9/12/2013 1:08:38 AM

I have undertaken a linear static analysis and have a range of utilisations from 0.01 to 1.013. Is it possible for Staad to show utilisations within a certain range e.g UR =0.5 to UR =0.9? I am able to manually select the members from the design results ta

Youcango

Go to the post-processing mode. YouNext, go to the Beam> Unity Check page. You canshouldbeableto see the UR reported in a tabular form. Click on the“Actual Ratio” column from the right hand side of the window. It arranges the table onin the ascending order of URURsByclickingon  Keepingthe“ctrl” button andclickingpressed,click on the beam numbers youhighlightin the table.Youwillseethat members with the UR ranging from 0.5 to 0.9 arehighlighted.

If you wish, you can right click on the GUI and choose New View > Display view in the active window from the floating window that pops up.

You can simply click on “Turn on/off Individual Beam Level” icon. On doing this you can see that there is a change in the cursor image. You can rubber band the portion on the members where you do not want to see the UR.

 

 

 

 


I have undertaken a linear static analysis and have a range of utilisations from 0.01 to 1.013. Is it possible for Staad to show utilisations within a certain range e.g UR =0.5 to UR =0.9? I am able to manually select the members from the design results ta

$
0
0
Revision 3 posted to Structural Analysis and Design Wiki by Kris Sathia on 9/12/2013 1:12:38 AM

I have undertaken a linear static analysis and have a range of utilisations from 0.01 to 1.013. Is it possible for Staad to show utilisations within a certain range e.g UR =0.5 to UR =0.9? I am able to manually select the members from the design results ta

Go to the post-processing mode. Next, go to the Beam> Unity Check page. You should be able to see the UR reported in a tabular form. Click on the “Actual Ratio” column from the right hand side of the window. It arranges the table in the ascending order of URs.  Keeping the “ctrl” button pressed, click on the beam numbers in the table. You will see that members with UR ranging from 0.5 to 0.9 are highlighted.

Ifyouwish

Todisplaytheminisolationfromtherestofthestructure, youcan right click on theGUIdrawingarea and choose New View > Display view in the active window from the floating window that pops up.

Youcansimplyclickon

The“Turn on/off Individual Beam Level” icon toocanbeusedtounclutterthedrawing. OndoingWhenyouselect this icon, you canwill see that there is a change in the cursor image. YoucanrubberRubber band theportiononawindowaround the members wherewhoseUR you do not want to seetheUR.

 

 

 

 

I have undertaken a linear static analysis and have a range of utilisations from 0.01 to 1.013. Is it possible for Staad to show utilisations within a certain range e.g UR =0.5 to UR =0.9? I am able to manually select the members from the design results ta

$
0
0
Revision 4 posted to Structural Analysis and Design Wiki by Kris Sathia on 9/12/2013 1:13:26 AM

I have undertaken a linear static analysis and have a range of utilisations from 0.01 to 1.013. Is it possible for Staad to show utilisations within a certain range e.g UR =0.5 to UR =0.9? I am able to manually select the members from the design results ta

Go to the post-processing mode. Next, go to the Beam> Unity Check page. You should be able to see the UR reported in a tabular form. Click on the “Actual Ratio” column from the right hand side of the window. It arranges the table in the ascending order of URs.  Keeping the “ctrl” button pressed, click on the beam numbers in the table. You will see that members with UR ranging from 0.5 to 0.9 are highlighted.

To display them in isolation from the rest of the structure, right click on the drawing area and choose New View > Display view in the active window from the floating window that pops up.

The “Turn on/off Individual Beam Level” icon too can be used to unclutter the drawing. When you select this icon, you will see that there is a change in the cursor image. Rubber band a window around the members whose UR you do not want to see.

 

 

 

 

Viewing members whose utilization ratio is within a desired range

$
0
0
Current Revision posted to Structural Analysis and Design Wiki by Kris Sathia on 9/12/2013 1:14:40 AM

Ihaveundertakenalinearstaticanalysisandhavearangeofutilisationsfrom0.01to1.013.IsitpossibleforStaadtoshowutilisationsViewingmemberswhoseutilizationratiois within a certaindesired rangee.gUR=0.5toUR=0.9?Iamabletomanuallyselectthemembersfromthedesignresultsta

Go to the post-processing mode. Next, go to the Beam> Unity Check page. You should be able to see the UR reported in a tabular form. Click on the “Actual Ratio” column from the right hand side of the window. It arranges the table in the ascending order of URs.  Keeping the “ctrl” button pressed, click on the beam numbers in the table. You will see that members with UR ranging from 0.5 to 0.9 are highlighted.

To display them in isolation from the rest of the structure, right click on the drawing area and choose New View > Display view in the active window from the floating window that pops up.

The “Turn on/off Individual Beam Level” icon too can be used to unclutter the drawing. When you select this icon, you will see that there is a change in the cursor image. Rubber band a window around the members whose UR you do not want to see.

 

 

 

 

"Unable to set application resource” message

$
0
0
Revision 1 posted to Structural Analysis and Design Wiki by Modestas on 9/12/2013 4:55:28 AM

  
 Applies To 
  
 Product(s):STAAD.Pro
 Version(s):N/A
 Environment: N/A
 Area: General
 Subarea: 
 Original Author:Modestas Turulis, Bentley Technical Support Group
  

 

 

 

 

 

 

 

Error or Warning Message

Message "Unable to set application resource” is being reported while opening STAAD.Pro:

Explanation

Usually this message indicates that some settings in the registries are not correct and require some modifications.

How to Avoid

Option 1:

1) Log in as an Administrator.
2) Click on Windows Start button and then click on Run (on Windows XP) or click on Start button and go to the Search field (on Windows 7).
3) Type in "Regedit".
4) Click on "OK".
5) Go to HKEY_CLASSES_ROOT > StaadPro > 2007 > Language.
6) Click on "Language" so that the key is highlighted in blue.
7) On the right window pane there should be a string value called "CurrentLanguage".
8) Is the data set to "USEnglish"? If not, double click on that string value to change the value data to "USEnglish". Please note that the value data is case sensitive.

Option 2

If that string is missing, uninstall STAAD.Pro and then install it by running as administrator. Please note that even if you are logged in as administrator, the installer of STAAD.Pro still has to be run as administrator (right click on the installation file and select option 'Run As Administrator') on Windows 7/8 operating systems.

See Also

STAAD.Pro [FAQ]

"Unable to set application resource” message

$
0
0
Current Revision posted to Structural Analysis and Design Wiki by Modestas on 9/12/2013 4:56:18 AM

"Unable to set application resource” message

STAAD.Pro,ErrorMessage

  
 Applies To 
  
 Product(s):STAAD.Pro
 Version(s):N/A
 Environment: N/A
 Area: General
 Subarea: 
 Original Author:Modestas Turulis, Bentley Technical Support Group
  

 

 

 

 

 

 

 

Error or Warning Message

Message "Unable to set application resource” is being reported while opening STAAD.Pro:

Explanation

Usually this message indicates that some settings in the registries are not correct and require some modifications.

How to Avoid

Option 1:

1) Log in as an Administrator.
2) Click on Windows Start button and then click on Run (on Windows XP) or click on Start button and go to the Search field (on Windows 7).
3) Type in "Regedit".
4) Click on "OK".
5) Go to HKEY_CLASSES_ROOT > StaadPro > 2007 > Language.
6) Click on "Language" so that the key is highlighted in blue.
7) On the right window pane there should be a string value called "CurrentLanguage".
8) Is the data set to "USEnglish"? If not, double click on that string value to change the value data to "USEnglish". Please note that the value data is case sensitive.

Option 2:

If that string is missing, uninstall STAAD.Pro and then install it by running as administrator. Please note that even if you are logged in as administrator, the installer of STAAD.Pro still has to be run as administrator (right click on the installation file and select option 'Run As Administrator') on Windows 7/8 operating systems.

See Also

STAAD.Pro [FAQ]

STAAD.Pro Plates And Solid Elements [FAQ]

$
0
0
Current Revision posted to Structural Analysis and Design Wiki by Shany on 9/12/2013 5:13:25 AM

STAAD.Pro Plates And Solid Elements [FAQ]

FAQs,STAADPro,selectservices,plates,platestress,solids

  
 Applies To 
  
 Product(s):STAAD.Pro
 Version(s):All
 Environment: N/A
 Area: Modeling & Postprocessing
 Subarea: Plates and Solids
 Original Author:Bentley Technical Support Group
  

 

 

 

 

 

 

 

  

  1. Is there a way to obtain the average stress at a node where several plate elements meet?
  2. In the plate element stress results, what do the terms TRESCAT and TRESTAB stand for? How are they calculated?
  3. I am modelling a concrete slab using plate elements. I am looking for the moments in the slab at the center of each element. I noticed that the output gives the bending moments per unit width. What is the per unit width? Would that be the thickness of the plate element?
  4. I have modeled a 40" x 40" column base plate with (4) 12" dia. pipe columns on it (equally spaced in both directions). How do I tell STAAD that the base plate will be on a concrete pedestal (f'c = 4.0 ksi)?
  5. How do you assign properties to solids?
  6. I would like to change the direction of the local Z axis of an element so that it points in the opposite direction. How do I do it?
  7. Is it possible to apply a concentrated force on the surface of an element? The point where the load acts is not one of the nodes of the element, as a result of which I cannot use the JOINT LOAD option.
  8. How can I find the maximum shear stress on my plate element model?
  9. The plate element results contain a term called TMAX. Is TMAX the best representation of the total stresses resulting from the torsion on the element?
  10. In the post processing mode - Results menu - Plate Stress Contour, there are two options called Max Top and Max Bottom. Are these direct stresses or flexural stresses?
  11. Can STAAD.Pro be used in designing a mat foundation?
  12. When modelling plate elements, should the individual elements satisfy any minimum requirements for the ratio of the length of their side to their thickness?
  13. I have a model where supports are defined at the nodes of some of the plate elements in the structure. If I divide the support reaction values by the thickness, length etc., of the side of the elements adjacent to the support, shouldn't the values match the ELEMENT NODAL STRESSES?
  14. Why shear stresses are not included in the Von Mises stresses for solid elements?
  15. How to change the local axis orientation X and Y for plates ?

1. Is there a way to obtain the average stress at a node where several plate elements meet?

Presently, STAAD only reports the nodal stresses of the individual elements meeting at the node. In the Plate page of the post-processing mode, the lower table on the right hand side of the screen contains the element nodal stresses. However, the average value from all such plates connected to the node is not reported.

Averaging is straightforward at joints that are only connected to one plane of plate elements and the loading is a normal pressure. However transverse shear will jump at a line if a line load is applied; so a single average would be inappropriate for that stress only. Similarly for stresses across a line of beams or walls or a line of bending moments; etc.

If two walls and a floor meet at a joint there are 3 planes that should be treated separately. Also averaging should be separate for the same surface on either side of a wall to account for the stress discontinuity. At the common joint there would be 12 sets of stresses (4 plates on each of 3 surfaces).

So averaging can be interrupted due to certain loadings, plates in other planes, and other members.

Further complexity occurs for contours and corner stresses if a shallow curved surface is being averaged. Most likely the inplane stresses should be averaged separately from the bending stresses, without coordinate transformations, since the flat plate faceted surfaces are trying to simulate a smooth surface.

The above considerations are not easily automated. We hope to implement at least some simple cases in future.

2. In the plate element stress results, what do the terms TRESCAT and TRESTAB stand for? How are they calculated?

TRESCA is 2.0 times TMAX. TMAX is the maximum inplane shear stress on a plate element. TMAX = 0.5 * max[abs((s1 - s2)) , abs((s2 - s3)) , abs((s3 - s1))] where s1 and s2 are the inplane principal stresses and the 3rd principal stress, s3, is zero at the surface. TRESCAT is the value for the top surface of the element. TRESCAB is on the bottom. Top and bottom are in accordance with the direction of the local Z axis.

Example problem 18 in the examples manual shows the calculation of TMAX

3. I am modelling a concrete slab using plate elements. I am looking for the moments in the slab at the center of each element. I noticed that the output gives the bending moments per unit width. What is the per unit width? Would that be the thickness of the plate element?

For Mx, the unit width is a unit distance at the center of the element, parallel to the local Y axis.

For My, the unit width is a unit distance at the center of the element, parallel to the local X axis. 

Diagrams explaining the various plates forces, moments and streses are available at section 1.6.1 of the Technical Reference manual.

4. I have modeled a 40" x 40" column base plate with (4) 12" dia. pipe columns on it (equally spaced in both directions). How do I tell STAAD that the base plate will be on a concrete pedestal (f'c = 4.0 ksi)? My first guess is to assign supports at the mesh intersections:

SUPPORTS 1 TO 529 ELASTIC MAT DIRECT Y SUBGRADE 4

Any suggestions?

Your guess is a good one. You can model the support as an elastic mat foundation. To do that, you first need to know the subgrade modulus of concrete. One of the methods by which the modulus can be computed is using the following equation:

Ks = Es / B ( 1 - PoissonRation * PoissonRatio )

( Reference: Foundation Analysis and Design ( Fifth Edition ) by Joseph E. Bowels Page 503 , Equation 9-6a )

In addition, if you want to make sure the concrete pedestal takes only compressive force, then specify the SPRING COMPRESSION command for those joints in the direction KFY.

An example of this is

SUPPORTS
1 TO 529 ELASTIC MAT YONLY SUBGRADE 987

SPRING COMPRESSION
1 TO 529 KFY

If you have any anchor bolts attached to the baseplate, they can be modeled as spring supports (tension only).

An example of this is

SUPPORTS
1000 TO 1004 FIXED BUT MX MY MZ KFY 5467

SPRING TENSION
1000 TO 1004 KFY

5. How do you assign properties to solids?

You do not have to assign any properties for solid elements. For solids, the only information required is their geometry (node numbers and their coordinates), and material constants (E, Poisson, etc.). You may refer to example problem 24 in the examples manual if you want details.

6. I would like to change the direction of the local Z axis of an element so that it points in the opposite direction. How do I do it?

From the Select menu at the top, select the Plates Cursor. Then select the element for which you want the Z axis direction changed. From the Commands menu, select Geometric Constants followed by Plate Reference Point and give the coordinates of this point. Choose the Local Axis direction to point towards or away from the Reference Point. The Assign option should be set to "To Selection". Click on OK.

7. Is it possible to apply a concentrated force on the surface of an element? The point where the load acts is not one of the nodes of the element, as a result of which I cannot use the JOINT LOAD option.

Yes, it is possible to do this. In Section 5.32.3 of the STAAD.Pro Technical Reference Manual, if you look at the syntax of the element pressure loading, you will find the following :

element-list PRESSURE direction x1 y1 x2 y2

In this syntax, (x1,y1) and (x2,y2) represent the corners of the region (on the element) over which the PRESSURE load is applied. However, if you omit the terms (x2,y2), the load will be treated as a concentrated force acting at the point (x1,y1), where x1 and y1 are measured as distances, from the centroid of the element, along the local X and Y axes, of the point of action of the load.

Thus, if you want to apply a 580 pound force along the negative global Z direction at a distance away from the centroid of (1.3,2.5)feet along the local X & Y axes of element 73, you can specify the following commands

UNIT POUND FEET
LOAD 1 CONCENTRATED LOAD ON WALL
ELEMENT LOAD
73 PR GZ -580.0 1.3 2.5

8. How can I find the maximum shear stress on my plate element model?

Since there are several types of shear stress results we can get from STAAD, the expression "maximum shear stress" needs to be clarified. So, let us first see what the choices are :

SXY - For any given element, this is the in-plane shear stress on the element and acts along the plate local X-Y axes directions.

TMAX - This is the maximum inplane shear stress on the element and is a composite of SXY and the stress resulting from torsion MXY.

SQX - This is the out-of-plane shear stress on the X face at the centroid of the element.

SQY - This is the out-of-plane shear stress on the Y face at the centroid of the element.

All of these results can be obtained in a report form, with additional options like sorting done in ascending or descending order for a user-defined set of elements and a user-defined set of load cases. As an example, do the following for getting a report of TMAX sorted in the order from maximum to minimum for all plates for load cases 4 and 5.

Go to the post-processing mode. Select all plates. From the Report menu, select Plate Results - Principal stresses. Select TMAX, and set the sorting order from High to Low. Switch on "Absolute values" also to perform sorting based on Absolute values. Click on the Loading tab, and select just cases 4 and 5. Click on OK. A report will be displayed. Click the right mouse button inside the table, and select Print.

9. The plate element results contain a term called TMAX. Is TMAX the best representation of the total stresses resulting from the torsion on the element?

Among the various stresses resulting from the torsional moment MXY, the only stress which is considered in TMAX is the shear stress. There are other stresses such as warping normal stresses which do not get represented in TMAX.

TMAX is the maximum inplane shear stress on an element for a given load case. It represents inplane shear stresses only. It contains contributions from the direct inplane shear stress SXY as well as the shear stress caused by the torsional moment MXY. Example 18 in the examples manual shows the derivation of TMAX from SXY and MXY.

While on the subject of shear stresses, one must note that the plate is also subjected to out-of-plane shear stresses SQX and SQY, which do not have any representation in TMAX.

10. In the post processing mode - Results menu - Plate Stress Contour, there are two options called Max Top and Max Bottom. Are these direct stresses or flexural stresses?

These are the principal stresses SMAX and SMIN. Principal stresses are a blend of axial stresses (also known as membrane stresses SX and SY), bending stresses (caused by MX and MY) and inplane shear stresses (SXY). Since the bending stresses have distinct signs for the top and bottom surfaces of the element, the principal stresses too are distinct for top and bottom. The derivation for principal stresses is shown in example 18 of the STAAD Examples manual.

11. Can STAAD.Pro be used in designing a mat foundation?

The answer to the question is Yes. The following are the major steps involved in the modelling and design of mat foundations using STAAD.

1) The mat foundation has to be modelled using finite elements. If the length and width of the mat are atleast 10 times larger than its thickness, plate elements can be used. If not, one may use 8 noded solid elements. The remainder of the structure involving the beams, columns and slabs also has to be modelled along with the mat. If beams share a common boundary with the mat and slabs, to ensure the proper transfer of load between the beams and the mat & slabs, the mat & slabs have to be divided into several elements, the beams have to be divided into several members, and the elements and members must share common nodes.

2) Generally, the supports for the mat are derived from the subgrade reaction of the soil. Using this attribute, and the influence area of each node of the mat, the spring constant for the supports may be derived. STAAD contains an automatic spring support generation facility for mat foundations. One may refer to Section 5.27.3 of the STAAD.Pro Technical Reference Manual for details on
this type of support generation.

3) Soil spring supports generally tend to be effective against resisting compressive forces only. They are ineffective in resisting uplift. This type of a unidirectional support requires those springs to be assigned an attribute call SPRING COMPRESSION.

4) The loads on the mat and the rest of the model have to be specified. Then, the structure has to be analyzed. This will generate the plate stresses and corner forces needed to design the mat.

5) You can then use the program's concrete design ability to design the individual elements which make up the mat. The only tedious aspect of this is that the program can presently design individual elements only. The task of taking the reinforcement values from each element and assembling the reinforcement picture of the overall mat has to be done by you manually.

We suggest you take a look at example problem number 27 in the STAAD.Pro examples manual for guidance on analysing mat foundations. In that example, the aspects explained in steps 1,2, 3 and 4 above are illustrated. Example problems 9 and 10 discuss concrete design of individual plate elements.

Note : A better option is to use STAAD.foundation software for design of mat. Mat modeled and analyzed in STAAD.Pro can be imported into STAAD.foundation will all results data and it can be subseqently designed in STAAD.foundation. One can also model and design mats directly in STAAD.Foundation.

12. When modelling plate elements, should the individual elements satisfy any minimum requirements for the ratio of the length of their side to their thickness?

No, they do not have to. However, for the overall slab or wall, if the span in either direction is less than 10 times its thickness, then the slab or wall becomes more like a solid than like a plate; and thick plate theory may not be adequate. In that case, 8-noded solid elements may be necessary.

13. I have a model where supports are defined at the nodes of some of the plate elements in the structure. If I divide the support reaction values by the thickness, length etc., of the side of the elements adjacent to the support, shouldn't the values match the ELEMENT NODAL STRESSES? I am aware of the fact that element stresses are in the local axis system of the element, and support reactions are in the global axis system, and am making the required transformations before making the comparison.

 The element nodal stresses are obtained as the value of the stress polynomial at the coordinates of those joints. Stresses in an element are most accurately determined only at the center of the element (in the middle of the joint displacement locations used in calculating that stress). The stress values calculated at the nodes will only be approximate (only the displacements of the joints from this one element are used in calculating the stress). Stresses at a joint would be improved if the stresses from the other elements at the joint (on the same surface) were averaged. Consequently, the comparison you suggest is not feasible.

A better alternative would be to compare the forces at the node rather than the stresses at the node.


The output for the command

PRINT ELEMENT FORCES

consists of the 3 forces and 3 moments at each of the nodes of the elements, reported in the global axis system. Thus, the output will consist of FX,FY,FZ,MX,MY,MZ with the 3 forces having units of force (not stress) and the 3 moments have units of moment (not moment per unit width). If you add up the values at the nodes of those elements which are connected to the support, those values must be equal to the support reaction.

Another consideration is the way in which element loads are evaluated and used. Staad computes the equivalent forces at the corner joints (same total force, center of force, and direction). The remainder of the analysis and results are as if you had applied the loads as joint loads rather than as element loads. Two exceptions, temperature loads are applied internally to the element and plate releases will affect the load distribution to the joints.

Say you have a wall with uniform pressure. Half of the load on the elements along the base will be applied directly to the base, the other half is applied to the line of joints at the top of these elements. So the internal transverse shears are too high at the top of the element. The transverse shears are OK at the center and too small at the base. The same will be true for the element force output of transverse forces. However, the reactions will have the entire force. A finer mesh in general, and near the base in particular, will improve the element stress and load distribution.

14. Why shear stresses are not included in the Von Mises stresses for solid elements?

Have a look at the attached figure which is from the following link: http://en.wikipedia.org/wiki/Von_Mises_yield_criterion

There are 2 equations for calculating Von Mises stresses.

The first equation uses the STAAD.Pro terms SXX, SYY, SZZ, SXY, SYZ and SZX.

The second equation uses the terms S1, S2 and S3. These are the principal stresses. There are no shear terms in this equation. This is the one implemented in STAAD.Pro.

The Von Mises stress should be the same from both equations.

15. How to change the local axis orientation X and Y for plates ?

Although it is very easy to flip the direction of the local Z axis for the plates by using the Commands > Geometric Constants > Plate Reference Point option, unfortunately there is no easy way to change the local X and Y for plates as needed. For example, if one needs to re-orient the local x for the plate to be parallel to the global X direction, one has to redefine the incidence of the plates by going to the STAAD editor and changing the ELEMENT INCIDENCE data manually. The local X would be a vector from the center of the plate, drawn in a direction from node1 to node2 and is hence dependent on the element incidences data. In other words the element incidences need to be such that node1 to node2 should be the direction of the global X. The rule which governs how the plate local axes are oriented, is explained under section 1.6.1 of the Technical Reference Manual..

 

16.WhatisthedifferencebetweenPlateelement,ShellelementandSurface?

 

Plateelementandshellelement

 BothtermsrepresentthesamethingintheSTAADcontext,whichis,a3-noded(triangular)ora4-noded(quadrilateral)elementtowhichathicknesshastobeassignedasaproperty.

InSTAAD,thiselementhasbothattributes-membrane(in-planeeffect)andbending(out-of-planeeffect).Thebendingeffectcan

beshutoffbydeclaringitasELEMENTPLANESTRESS.Thein-planeeffectcan'tbeshutoff.

 

PlateElementandSurface

 Ifyouwanttomodelastructurewhichcontainsawall,slaborpaneltypecomponent,youhavetwochoicesinSTAAD:

 

a)Modelthatpanelusingacollectionofindividualelements.Thisiscalledafiniteelementmesh.Thisisanassemblyofthe2dtriangularand/orquadrilateralelementsdescribedabove.

 

b)ModelthatasasinglephysicalobjectcalledaSurface.

 Option(a)isachievedusingthemeshgenerationfacilitiesinSTAAD.

 Inoption(b),(surfaceobject),whathappensunderthehoodisthat,duringtheanalysis,STAADtransformsthesurfaceintoafiniteelementmesh.Thetypeofmesh(numberofelements,

typeofelements,sizeofelements,etc.)thatisgeneratedfromthesurfaceisbasedontheparametersthatyouprovideatthetimeofdefiningthesurface.Thedetailsofthemeshthus

 generatedaretoalargeextent,maskedfromtheuser.Resultsarepresentedforthatsurface,notfortheindividualelementsthatitismadeupof.

 Inotherwords,asurfaceismerelyanobjectthatrepresentsacollectionofelements.Whentheprogramgoesthroughtheanalysisphase,itsubdividesthesurfaceintoaplateelements.Fromanalysispointofview,bothplateandsurfacearethesamething.Thedifferenceisintheinterpretationofresults.Forplates,thestressesarereportedwhileforSurfacetheforceisreported.

 

 

See Also

Product TechNotes and FAQs

Structural Product TechNotes And FAQs

External Links

Bentley Technical Support KnowledgeBase

Bentley LEARN Server

Comments or Corrections?

Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

 

STAAD(X) Tower

$
0
0
Current Revision posted to Structural Analysis and Design Wiki by Shany on 9/12/2013 5:55:03 AM

STAAD(X) Tower

STAAD(X)Tower,communicationstower,towerdesign

STAAD(X) Tower is a powerful addition to Bentley Systems, Inc.’s line of structural engineering software tools. It performs the comprehensive design and analysis of various types of communication structures such as tapered monopoles, stepped poles, 3-legged or 4-legged self-supporting and guyed towers. STAAD(X) Tower helps engineers to generate the physical model using parametric setup wizards and categorizes the panels/sections, legs, horizontals, and bracing members with orientations without manual intervention. The structure can easily be edited to achieve the desired shape and configuration.

Browse related content tagged: STAAD(X) Tower

Resources

Tutorials

FAQs and TechNotes

Release Notes

Product Site

Knowledge Base

Training Courses

Documentation

File a Service Ticket

Discussion

Got a question? Ask your peers in our forums:

Structural Analysis & Design Forums


Popular Forum Threads

STAAD(X) Tower

Search for: STAAD(X) Tower

News and Events

 

Related Blogs


The Bentley Structural Blog

Videos

 

Key Features

  •  

Files and Interoperability

  •  

Product History

 

Related Links

Related products: [[STAAD.Pro]]


STAAD.Foundation FAQs

$
0
0
Current Revision posted to Structural Analysis and Design Wiki by Payel on 9/12/2013 4:20:26 PM

STAAD.Foundation FAQs

FAQ,SELECTsupport,STAAD.foundation,GeneralFoundation,Pilecap,multiplecolumn

  
 Applies To 
  
 Product(s):STAAD.foundation
 Version(s):06.00.00.11
 Environment: N/A
 Area: General Foundation
 Subarea: 
 Original Author:Sye Chakraborty, Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

Following are a list of FAQs related to STAAD.Foundation/ STAAD.Foundation Advanced

  1. I have multiple columns which are supported by a single pile cap. How can I model that in STAAD.foundation
  2. I modeled a steel structure and want to design pile cap on piles for foundation. Can I import the support reaction from STAAD.Pro. ? Can STAAD.Foundation design this entirely or does it need to be modeled in STAAD.Pro ?
  3. When I start up STAAD.foundation, I get a message "SELECT license type is not configured yet. Please run SELECT License Asistant to configure it".
  4. I have a problem in staad foundation, the mat foundation is not working only the isolated footing working.

1. I have multiple columns which are supported by a single pile cap. How can I model that in STAAD.foundation ?

As of now a pile cap, created in STAAD.foundation using the pile cap job type, can only support one column point. If you have multiple columns which are supported by a single pilecap, you will have to create it as a Mat Foundation job and then model the pile cap as a mat. The piles can then be specified under the mat using the Pile spring option.

 

2. I modeled a steel structure and want to design pile cap on piles for foundation. Can I import the support reaction from STAAD.Pro. ? Can STAAD.Foundation design this entirely or does it need to be modeled in STAAD.Pro ?

Support reactions from STAAD.Pro can be directly taken into STAAD.foundation using the Foundation Design tab within STAAD.Pro and then the pile cap can be designed in STAAD.foundation. For this process there is no need to model pile caps in STAAD.Pro.

If you are asking whether STAAD.Foundation can be used as a standalone application for design of pile caps, then the answer is yes. For that you have to manually enter the column locations and then enter the column reaction loads in STAAD.foundation. If you are modeling the superstructure in STAAD.Pro for analysis, then getting support reactions from STAAD.Pro would spare you the effort of defining the column points and re-entering the loads in STAAD.Foundation and so the process would be a lot faster.

 

3. When I start up STAAD.foundation, I get a message "SELECT license type is not configured yet. Please run SELECT License Asistant to configure it".

This issue occurs in Windows Vista/7/8 machines, if STAAD.foundation program is not installed with enough administrative privileges.This prevents the registry to be set properly.

To resolve this, right-click on the shortcut for STAAD.foundation in your desktop, and select the option "Run as Administrator". This fixes the registry issue. Next time you can run the program by double-clicking on the shortcut.

To prevent this, when you install STAAD.foundation in Windows Vista/7/8 machine, right-click on the .msi/.exe file and select the option "Run as administrator". This ensures that the resistry is set propely.

 

4. I have a problem in staad foundation; the mat foundation is not working, only the isolated footing is working.

Please install STAAD Foundation Advanced V8i  in your machine. STAAD.foundation from STAAD.Pro does not support Mat foundation (assuming that you are using STAAD.Pro V8i Build #20.07.08..20 or later version). It
supports only Isolated, combined and Pile cap modules in general mode. TorunthisSTAAD.foundationAdvancedmodule,youmusthavealicenseforit.

 

See Also

[[Structural Product TechNotes And FAQs]]

"Copy protection device/system does not support AISC/ASD code." The design will not be performed.

$
0
0
Revision 1 posted to Structural Analysis and Design Wiki by Payel on 9/12/2013 11:13:45 PM

"Copy protection device/system does not support AISC/ASD code." or "Copy protection device does not support the Aluminum design code" or "Copy protection device/system doesnot support BS 5950/2000 (British steel design code)." The design will not be performed.

When you run STAAD.Pro, in the very first page, there is a section called License Configuration. There are check boxes next to the design codes. Check the box for the US design code or the codes you have licenses for; the circle next to it/them should turn green. Aluminum design code is part of the US Specialized design code.

Please note that if you have purchased Canadian code, you will be checking the Canadian/Australian/South African code in the License Configuration and it should turn green. Similarly if you have purchased the British code, then you will be selecting it and it should turn green. In case, the circle turns red, then you might not have license for the code. You can check the availability of your license through the License Management Tool. Also, there should be at least one license available for a design code to be used. In case, it says '0', check with your IT administrator. He can determine which machine is using the license at that time.

"Copy protection device/system does not support AISC/ASD code." The design will not be performed.

$
0
0
Current Revision posted to Structural Analysis and Design Wiki by Payel on 9/12/2013 11:18:36 PM

"Copy protection device/system does not support AISC/ASD code." The design will not be performed.

Copyprotectiondevice/system,AISC/ASD,AluminumDesigncode

Description

WhenItrytoruntheanalysiswithadesigncode,Igetthemessage"Copy protection device/system does not support AISC/ASD code." or "Copy protection device does not support the Aluminum design code" or "Copy protection device/system doesnot support BS 5950/2000 (British steel design code)." The design will not be performed.

Solution

When you run STAAD.Pro, in the very first page, there is a section called License Configuration. There are check boxes next to the design codes. Check the box for the US design code or the codes you have licenses for; the circle next to it/them should turn green. Aluminum design code is part of the US Specialized design code.

Please note that if you have purchased Canadian code, you will be checking the Canadian/Australian/South African code in the License Configuration and it should turn green. Similarly if you have purchased the British code, then you will be selecting it and it should turn green. In case, the circle turns red, then you might not have license for the code. You can check the availability of your license through the License Management Tool. Also, there should be at least one license available for a design code to be used. In case, it says '0', check with your IT administrator. He can determine which machine is using the license at that time.

STAAD.Pro [FAQ]

$
0
0
Revision 17 posted to Structural Analysis and Design Wiki by Payel on 9/12/2013 11:22:11 PM

STAAD.Pro [FAQ]

FAQs, STAAD.Pro

Frequently asked questions for STAAD.Pro:

  • [["Copyprotectiondevice/systemdoesnotsupportAISC/ASDcode."]]
  • [[FAQ ON STAAD LICENSE - USL versus STANDARD]]
  • [[STAAD.Pro General [FAQ] ]]
  • [[STAAD.Pro Aluminum Design [FAQ] ]]
  • [[STAAD.Pro Concrete Design [FAQ] ]]
  • [[STAAD.Pro Developing The Model [FAQ] ]]
  • [[STAAD.Pro Driver Downloads [FAQ] ]]
  • [[STAAD.Pro Eigen Solution [FAQ] ]]
  • [[STAAD.Pro Instability And Zero Stiffness [FAQ] ]]
  • [[STAAD.Pro Load Generation [FAQ] ]]
  • [[STAAD.Pro Member Specification [FAQ] ]]
  • [[STAAD.Pro Miscellaneous [FAQ] ]]
  • [[STAAD.Pro PDELTA Analysis [FAQ] ]]
  • [[STAAD.Pro Plates And Solid Elements [FAQ] ]]
  • STAAD.Pro Postprocessing [FAQ]
  • [[STAAD.Pro Response Spectrum [FAQ] ]]
  • [[STAAD.Pro Steel Design [FAQ] ]]
  • [[STAAD.Pro Timber Design [FAQ] ]]
  • [[STAAD.Pro Time History Analysis [FAQ] ]]
  • [[STAAD.Pro Tutorials [FAQ] ]]
  • [[STAAD.Pro Import/Export [FAQ] ]]

 

 

 

STAAD.Pro Licensing [FAQ]

$
0
0
Revision 1 posted to Structural Analysis and Design Wiki by Payel on 9/12/2013 11:39:48 PM

This page contains a list of licensing issues related to STAAD.Pro :

Viewing all 8748 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>