Design codes supported by STAAD design code licenses

$
0
0
Current Revision posted to RAM | STAAD Wiki by Seth Guthrie on 2/22/2017 4:09:27 PM
  
 Applies To 
  
 Product(s):STAAD.Pro
 Version(s):All
 Environment: N/A
 Area: Design
 Subarea: General Design Solutions
 Original Author:Jeremy Hoesly, Bentley Technical Support Group
  

This article guides users to a list of design codes supported within STAAD.Pro along with the licenses that include them.

Background

STAAD.Pro supports several international design codes. These design codes are grouped together and supported with specific design code licenses. However, the groupings are not always obvious. Fortunately, STAAD.Pro includes in the documentation a list of supported codes along with the licenses that cover them.

Steps to Accomplish

  1. Select from the Windows Start menu:
    All Programs -> Bentley Engineering -> STAAD.Pro V8i -> STAAD.Pro Online Documentation

  2. In the window that appears, click the Contents tab on the left pane.

  3. Expand the first topic titled Welcome to STAAD.Pro V8i.

  4. Select the listing titled Available Design Codes in STAAD.Pro.

See Also

[[STAAD.Pro TechNotes and FAQs]]

Tags: design codes supported in STAAD.Pro, How to check design code versions, Design Code Versions, STAAD.Pro Design Codes, design codes

Structural Enterprise

$
0
0
Current Revision posted to RAM | STAAD Wiki by Seth Guthrie on 2/22/2017 6:49:03 PM

Structural Enterprise is a special software license that provides access to an entire suite of structural analysis and design software. Under Structural Enterprise, a user has unlimited access to the entire RAM product line and most of the STAAD and Microstran product lines. Structural Enterprise consolidates numerous individually priced applications to a single package and maintenance fee.

[[How do I install Structural Enterprise?]]

Structural Enterprise Setup Wizard

Tags: Structural Enterprise, Setup Wizard, RAM, Microstran, STAAD, Limcon

I upgraded to latest RAM Concept version and I'm getting message regarding license overage

$
0
0
Revision 1 posted to RAM | STAAD Wiki by Payel on 2/22/2017 10:29:08 PM

 Applies To 
 Product(s):RAM Concept
 Version(s):6.02
 Environment: N/A
 Area: Licensing
 Original Author:Payel Sasmal, Bentley Technical Support Group

I upgraded to latest RAM Concept version and I'm getting the following message regarding license overage.

From RAM Concept release 06.02, we have introduced this informational message to let the user know that they are going to use the Post Tension Module license. 

Once you start the program, you will get the following dialog box. You must have checked the option to use the Post Tension license to get the above warning message.

To avoid any over-usage of the Post Tension license, go under Help - Manage Licenses and make sure that under 'License Checkout' section, either Structural Enterprise License or RAM Concept Post Tension module license is present in the available pool of license. 

If this check was unintentional, you can opt out by going under Help - Manage License Restrictions and uncheck the box.

Please note that the Floors and Mats module are now included in the RAM Concept license.

The tools and features that require a "RAM Concept Post Tension Module" (1479) and incur usage in the current version of the program is described in the link below:

RAM Concept Licensing and Usage of Post Tension (PT) Features

See Also

Structural Products Licensing [FAQ]

How products that use the Bentley IEG License Service are licensed

Structural Product TechNotes And FAQs

Tags: please confirm the license change, RAM Concept Post Tension

RAM Structural System Support Solutions

$
0
0
Revision 33 posted to RAM | STAAD Wiki by Wentao Zhang on 2/23/2017 12:59:01 AM

The TechNotes and FAQs in this section cover various topics that pertain to RAM Structural System. Use the navigation tree on the left or the popular links below to browse.

Release Notes and New Issues

General

RAM Modeler

RAM Steel

RAM Frame

Criteria and Lateral Load topics

Analysis Considerations

Code Specific and Steel Design Topics

Buckling Restrained Braced Frames

Reports and Output

RAM Concrete

RAM Foundation

Ram Interop

RAM DataAccess

Tags: RAM Structural System, index, Support Solutions

Appendix C: Product Licensing FAQ

$
0
0
Current Revision posted to RAM | STAAD Wiki by Allen Adams on 2/24/2017 12:21:32 AM

Appendix C

 

Product Licensing FAQ – RAM Structural System

Licensing Options

The RAM Structural System is composed of several modules, each of which has their own licenses. The program also contains links to two related Bentley products, RAM Concept and RAM Connection, providing design interoperability, as well as a link to Bentley’s ProjectWise for project management. Each of those programs also have their own licenses. It is possible to have several licenses of one or more modules, and few or no licenses of other modules. Because of the ease with which these various modules and programs can be invoked, a method of restricting the use of each has been incorporated in order to prevent unwanted or inadvertent usage by an unsuspecting user from being logged against the licenses that the company actually owns.

These modules are invoked using the tool bar buttons on the left of the RAM Manager screen:

or by using the Model or Design menu items:

If RAM Concept or RAM Connection are not installed, they will not be available to be selected.

There is no license associated with RAM Manager, so no usage data is logged against it, but usage data is logged against each of the other modules as soon as they are invoked.

There is no demo version available for the RAM Structural System modules.

 

Versions 14.07, 15.00, 15.01, 15.02, 15.03, 15.04

In RAM Manager, the Tools – Manage License Restrictions command opens the following dialog:

This provides a mechanism for the user to prevent a module from being inadvertently executed. When the program is first installed all of these options are selected. It is important therefore to execute this command and deselect any modules or links for which the user wants to restrict access.

To prevent a module or program link from being executed, deselect that item.

If a module is deselected here and that module or link is subsequently invoked, the following dialog appears:

If Allow is selected the module will open, and usage will be logged. If Cancel is selected the module will not open and no usage will be logged. Settings opens the previous command, allowing the user to modify the selections of the allowed modules.

 

Versions 14.06 and earlier

Versions prior to V14.07 lacked the ability to manage these license restrictions, restrictions could only be achieved by deleting the module from the installation Prog directory. If you are using an earlier version and want to prevent use of a module, delete the file(s) listed here for the module to be prevented:

RAM Steel:

RamBeam.exe, RAMColumn.dll

RAM Concrete:

RAMConcAnalysis.dll, RAMConcreteBeam.dll, RAMConcreteColumn.dll, RAMConcreteShearWall.dll

RAM Frame Analysis:

RAMFrameAnalysis.dll

RAM Foundation:

RamFoundation.exe

 

Tags: RAM Structural System, release notes, 15.04, licensing

RAM SS V15.04 Release Notes

$
0
0
Revision 2 posted to RAM | STAAD Wiki by Allen Adams on 2/24/2017 12:22:33 AM

RAM Structural System CONNECT Edition Update 4 Release 15.04

Release Notes

 

Release Date: February 22, 2017

 

This document contains important information regarding changes to the RAM Structural System. It is important that all users are aware of these changes. Please distribute these Release Notes and make them available to all users of the RAM Structural System.

 

Tutorial:

The Tutorial Manual has not been updated but is still valid. The appearance of some parts of the program in this version may differ from that shown in the Tutorial.

 

Important Notices:

This version automatically converts databases created in previous versions to the new database format. Note that a backup file is created automatically when a database is converted; the name of the database is the same, with “Orig” and the version number appended to the name. The file has an extension of “.zip” and is located in the same directory as the original database.

 

The previous steel tables and load combination templates supplied with the program will be replaced with new tables and templates of the same name. If you have customized any Master or Design tables or load combination templates supplied with the program without changing the file names, those file names should be renamed from the original RAM table names prior to installation to prevent your changes from being lost.

 

Installation Instructions:

This version can be found on the Bentley Software Fulfilment web page by logging into the Personal Portal or the Enterprise Portal and selecting the Software Downloads icon. Perform a search for “RAM Structural System”, select any of the RAM Structural System modules (e.g., RAM Modeler; they all use the same installer), and select the latest version of the RAM Structural System.

 

Product Licensing FAQ:

Appendix C contains a document describing features available in the RAM Structural System to help prevent inadvertent use of unlicensed modules. Refer to that document for more information.

 

New Features and Enhancements:

For details on these new features and enhancements, refer to the manual .pdf files available from the Help menu in each module or from the Manuals folder on your hard drive.

 

This version contains two powerful new features that have been designated Technology Preview features. They are features that are in a state that would previously been referred to as a Beta version. These two features are Analytical Insights and SQLite database of result. It is likely that these features will continue to undergo revisions based on feedback from users. Care should be taken if these are used for actual design, because they are still in the process of being revised they have not gone through the rigorous testing process. They are being made available so that you can use them with real models in real design situations, and provide us with feedback and suggestions for making these features more useable and productive.

 

Analytical Insights – Technology Preview

The Analytical Insights feature analyzes your model and compares them with a set of Structural Performance Indicators (SPI). These SPI’s can be configured to conform to your office standards and practices, and prioritized according to their importance. Your model is then scored based on these SPI’s helping you identify possible changes to the model to make it more economical or constructable. See Appendix A for more information.

 

SQLite Database of Analysis and Design Results – Technology Preview

In order to more easily access the geometry and analysis data, this data is now written out to SQLite files. A report generator is provided that can be used to create a .xlsx file that can then be used in spreadsheets in Excel. The file can be customized to contain the information that you want made available. See Appendix B for more information.

 

Wind Tunnel Results Load Cases

In RAM Frame a new Wind Load case generator has been added, allowing the results of wind tunnel tests to be input (Fx, Fy, Mz, and coordinates at each level, and the percent of each of those forces to be applied as a load case), and the myriad load cases with their resulting story forces are created and analyzed. The wind tunnel load cases are specified using the Loads – Load Cases command, specifying Wind, and selecting Wind Tunnel from the list of wind load generators. The data can be entered manually or the data can be pasted in from Excel. In the Load Case control select the top Story to paste a block of data, or any story to paste a single line of data, so that the desired row of the chart is highlighted, then select the Paste icon (or Ctrl-v). In the Cases control select Case #1 to paste a block of data, or any Case # to paste a single line of data, so that the row is highlighted, then select the Paste icon (or Ctrl-v).

 

Mode Shape Values in Periods and Modes Report

In the Periods and Modes report the values listed for the Mode Shapes are now given in scientific notation. Previously they were listed in decimal values, which often did not give enough significant digits for the smaller values.

 

UK Eurocode National Annex and BS 6399 Live Load Reduction

The option in Criteria – Member Loads to perform Live Load Reduction per the UK National Annex to the Eurocode and BS 6399 has been split into two separate options. Although the Live Load Reduction methodology is identical in both, the selection in this command is used to determine the nomenclature used in the Modeler, which previously assumed that the user intended to design per the British Standards such as BS 5950, rather than per the Eurocode. This resulted in some confusion since the nomenclature is different between those two codes, particularly fck vs fcu. Now when the UK National Annex to the Eurocode is selected, the nomenclature used in the Modeler will be the same as for the Eurocode.

 

Eurocode and UK National Annex Design fy

In Criteria – Eurocode Factors an option is now available to specify that the Design fy rules be used based on either EN 1993-1-1 or EN 1993-1-1 UK NA. Previously the Design fy rules per EN 1993-1-1 were used, the option to use the EN 1993-1-1 UK NA rules is now available.

 

Eurocode EN 1991-1-4:2005 Wind and UK NA

In RAM Frame, wind load generators for EN 1991-1-4:2005 and EN 1991-1-4:2005 UK National Annex have been implemented.

 

Eurocode Notional Loads

Notional loads per EN 1993-1-1 can now be generated.

 

Eurocode Load Combinations

The Eurocode Load Combination templates have been updated to include Notional Loads in the combinations. Notional loads were added to the EN 1990:2002 +A1:2005 steel design combination template and the EN 1990:2002 +A1:2005 UK NA steel and concrete design templates.

 

Singapore Eurocode National Annex Live Load Reduction

An option has been added to Criteria – Member Loads to perform Live Load Reduction per the Singapore National Annex to the Eurocode.

 

AISC 360-10 RM Value for B2

In the AISC 306-05 specification the value of RM used in the calculation of B2 was limited to 0.85 and 1.0. This changed in AISC 360-10, in which RM is a calculated value. The command was enhanced to allow input of any value of RM between 0.85 and 1.00.

 

Cw

A more accurate method for calculating Cw for I-shaped members has been implemented. This will have a minor impact on designs, and only when Cw was used in the calculation of capacities.

 

Eccentric Loading on Semi-rigid Diaphragms

For large models the time required to perform the calculation of the loads for the eccentric load cases on semi-rigid diaphragms has been reduced significantly (from hours to minutes).

 

Eccentric Dynamic Load Cases

For large models the time required to perform the eigen solution analysis for dynamic load cases with eccentricities has been reduced significantly.

 

SidePlate with HSS Columns

At the request of SidePlate, Square HSS columns are now accommodated and pass compatibility checks for the SidePlate connection. Previously, only wide flange shaped columns were permitted with the SidePlate connection. Rectangular HSS columns are not permitted at this time. The engineer should discuss any concerns with SidePlate and verify that their connections are constructible.

 

SidePlate Geometric Compatibility Check

At the request of SidePlate, the geometric compatibility check that the program performs to determine if the beam flange width and column flange width are compatible has been simplified. If the column flange width is not at least 1.5” greater than the beam flange width, a warning is given indicating that the beam may be too wide and may not permit the use of the SidePlate connection. Also, previously the compatibility check gave an Error instead of a Warning, and would not proceed with the analysis. Now it is given as a Warning, and the analysis will proceed, but the engineer should discuss the condition with SidePlate to verify that it is constructible.

 

Seismic Provisions Joint Check Summary Report

The Seismic Provisions Joint Check Summary Report has been simplified; previously the report repeated the global general criteria under each joint summary, now it only shows the criteria data at the beginning of the report. Also, some additional pertinent criteria items have been added to that section of the report.

 

RAM Concrete Dependency on Steel Design Removed

Previously, for models containing both steel and concrete members, the analysis in RAM Concrete could not be performed if the steel beam and column sizes were not current. This required that if any change was made in the Model or to the Criteria, the Design-All command had to be performed in RAM Steel Beam and RAM Steel Column before an analysis could be performed again in RAM Concrete. Since the steel sizes had little impact on the Concrete analysis, this restriction has been removed. The model status shows that the designs and analysis are not strictly up-to-date, but for convenience the analysis and subsequent concrete design is allowed.

 

Mesh Warning in RAM Concrete

When decks don’t completely cover the slab a mesh warning is now given in RAM Concrete indicating the story and the diaphragm, and indicating that the deck properties cannot be identified and that they won’t be included in the analysis. When this warning is given the user should inspect the deck polygons in the Modeler and correct so that the entire diaphragm has slab properties.

 

Members Not Designated as Part of the Seismic-Force-Resisting System

Section 21.13 of ACI318-11 has extensive rules for the seismic design of gravity concrete members that aren’t part of the seismic-force-resisting system. Previously a portion of these requirements were implemented and reported; in this version these provisions are more extensively implemented and reported. These now include:

  • Detailing requirements when the gravity load does not exceed Agf’c/10.

  • Two continuous bars at both top and bottom per Section 21.5.2.1.

  • Stirrups to be spaced at not more than d/2 throughout the length of the member per Section 21.13.4.2.

  • Design shear force, Ve, determined per Section 21.5.4 by assuming that moments of opposite sign corresponding to probable flexural moment strength, Mpr, act at the joint faces and that the member is loaded with the factored tributary gravity load along the span.

 

Coupling Beam Effective Depth

When designing coupling beams of shear walls to the ACI design codes, the effective depth was approximated as 0.8H. The accurate effective depth for the provided bar layers is now used.

 

Service Request Manager

The Service Request Manager, for logging requests for technical support, is available directly from the Help – Technical Support command in the RAM Manager.

 

ISM

Extensive work was performed to enhance the ISM interoperability (used to import and export data between Bentley products such as STAAD, and third-party products such as Revit and Tekla). Some of the more prominent enhancements are listed here.

 

  • Gravity loads, including snow and snow drift loads as modelled in RAM Modeler can now be exported to ISM. Gravity loads in RAM Structural System consist of several load components including Construction, Dead, Live, Construction Live and Partition; when exported to ISM these are separated into individual cases. Exported Surface loads are clipped to the slab boundary and openings. Note that in the ISM viewer this provides a 3D view of the applied loads in the model.

  • Pile caps are now exported to ISM

  • Diagonal Reinforcing in shear wall coupling beams, designed in the Shear Wall module, is now exported to ISM.

  • Concrete shear wall horizontal bars are now exported with 180-degree hook end conditions.

  • Modulus of elasticity of concrete in concrete walls can be specified in the RAM Structural System either as the value determined by the code equations or as a specific user-defined value. Previously the option to use the value calculated by code was not available for the data that was exported to ISM. Now that flag is passed to ISM, which will calculate the value of the Modulus of Elasticity the same as the program does.

 

 

Error Corrections:

Some program errors have been corrected for Version 15.03. Corrections made to graphics, reports, Modeler functions, program crashes, etc that were considered minor are not listed here. The noteworthy error corrections are listed here in order to notify you that they have been corrected or to assist you in determining the impact of those errors on previous designs. These errors were generally obscure and uncommon, affecting only a very small percentage of models, or had no impact on the results. The errors, when they occurred, were generally quite obvious. However, if there is any question, it may be advisable to reanalyze previous models to determine the impact, if any. In each case the error only occurred for the precise conditions indicated. Those errors that may have resulted in un-conservative designs are shown with an asterisk. We apologize for any inconvenience this may cause.

 

RAM Steel Beam

SHEAR AT POINT LOAD*: When the Shear at a point load location is governed by the shear slightly left of the point load, that left Shear value was not captured.

Effect: Some codes require calculation of Shear corresponding to the Moment at a given location. At point load locations, the Shear slightly left of the point load, if greater than the Shear slightly right of that point load location, was not captured as the max Shear at location of that point load. A lesser Shear value was then associated with the Moment at that location.

 

AISC 360 - COMPRESSION FLANGE YIELDING*: For Singly symmetric I-sections the compression flange yielding capacity determined in Section F4 for qualifying sections was incorrectly determined.

Effect: Where the governing capacity for sections evaluated under Section F4 was the Compression Flange Yielding limit, the reported capacity was incorrectly determined as FyZx rather than RpcFySxc per Equation F4-1. Note that this error only affected built-up sections where the top flange and bottom flange had different dimensions; it did not affect the design of the standard rolled I-shapes.

 

EUROCODE SECTION CLASSIFICATION*: Members under pure flexure were always given a classification of 1 even if they should have been assigned a higher class.

Effect: While members under axial or combined loads were correctly classified, members under pure flexure may have erroneously been given a classification of 1.

 

AISC 360 BUILT-UP CHANNELS WITH NONCOMPACT OR SLENDER WEBS*: The design of built-up channels with noncompact or slender webs has not been implemented in the program, but for such members the program was giving design results (erroneously), with incorrect capacities indicated in the design report.

Effect: Built-up channels with non-compact or slender webs were incorrectly designed and reports showed incorrect results. Capacities for such sections are not addressed by the Specification and the program should have indicated a warning message to the user instead. The user is now warned of the condition with a “Cannot Design” warning message, and the capacity is set to 0.0.

 

AISC 360 ASYMMETRIC BUILT-UP CHANNELS*: The design of asymmetric built-up channels has not been implemented in the program, but for such members the program was giving design results (erroneously), with incorrect capacities indicated in the design report.

Effect: Built-up asymmetric channels were incorrectly designed and reports showed incorrect results. The program should have indicated a warning message to the user instead. The user is now warned of the condition with a “Cannot Design” warning message, and the capacity is set to 0.0.

 

AISC 360 BUILT-UP BOX SHAPES WITH SLENDER WEBS*: The design of built-up box shapes with slender webs has not been implemented in the program, but for such members the program was giving design results (erroneously), with incorrect capacities indicated in the design report.

Effect: Built-up box shapes with slender webs were incorrectly designed and reports showed incorrect results. The program should have indicated a warning message to the user instead. The user is now warned of the condition with a “Cannot Design” warning message, and the capacity is set to 0.0.

 

AISC 360 DOUBLY SYMMETRIC BUILT-UP I-SECTION (LTB CAPACITY): The reported AISC 360 LTB capacity for doubly symmetric built up I-sections was incorrect.

Effect: Where LTB governed the design for compact doubly symmetric built up I-sections, the reported capacity was inconsistent with the requirements of AISC 360 section F2. An incorrect, but conservative, rts value was being used.

 

MAXIMUM FORCE FOR COMPOSITE BEAMS WITH PARALLEL DECK: For beams with parallel decks where the max number of rows that can be supported by the beam was greater than one, the program erred in its determination of the maximum force that could be provided if all the rows were filled with studs.

Effect: Stud designs for composite beams with parallel decks and which could support more than one row of studs may have been erroneous. Beams that may have otherwise passed designs may have been skipped for heavier beam designs.

 

RAM Steel Column

COLUMN UNBRACED LENGTH*: An incorrect unbraced length was determined for multi-story column segments (where the column extended multiple levels between levels where it is laterally braced) in the stack where the column orientation angle was greater than zero and less than 90 degrees.

Effect: Unbraced lengths for multi-story columns having an orientation angle between 0 and 90 degrees were incorrectly determined. All other columns were correctly designed.

 

AISC 360 W- AND C-SHAPES WITH MINOR AXIS BENDING*: Wide flange and Channel shapes subjected to minor axis bending were not correctly designed according to the provisions in AISC 360 Chapter F6 when the governing limit state was Flange Local Buckling.

Effect: For Wide flange and Channel shapes with minor axis bending, the reported bending capacities were incorrect when Flange Local Buckling governed the design.

 

AISC 360 - ROUND HSS WITH SLENDER WALLS*: The design of round HSS with slender walls exceeding the limit set in Section F8 has not been implemented in the program, but for such members the program was giving design results (erroneously), with incorrect capacities indicated in the design report.

Effect: Round HSS with slender walls exceeding the limit in F8 were incorrectly designed and reports showed incorrect results. The program should have indicated a warning message to the user instead. The user is now warned of the condition with a “Cannot Design” warning message, and the capacity is set to 0.0.

 

AISC 360 WT STRONG AXIS BENDING*: The flexural capacity reported for WT shapes was incorrect.

Effect: Under flexure, the reported capacity of WT sections did not meet Yielding requirements of Section F9-1.

 

AS 4100-98 VIEW/UPDATE INTERACTION: The controlling interaction reported in View/Update for columns under compression and weak axis bending was not consistent with the governing interaction shown in the detailed column report.

Effect: While columns subjected to axial and weak axis bending were correctly designed and the governing interaction shown in the column design report was also correct, the controlling interaction displayed in the View/Update dialog was incorrect for AS 4100-98. Also the reference for the controlling interaction shown in the Summary Report was incorrect.

 

RAM Concrete Beam

ACI SMF BEAM SHEAR CAPACITY*: Requirements for ACI 318-11 clause 21.5.4.2.a and 21.6.5.2.a (and similar clauses in previous versions) were incorrectly applied.

Effect: Shear capacity of SMF beams may have been overestimated when ACI 318-11 21.5.4.2 and 21.6.5.2 apply.

 

RAM Concrete Column

ACI CONCRETE COLUMN DESIGN*: When designing columns that are part of an IMF or SMF system, that span multiple stories and are unbraced by beams at the intermediate levels, the program might have calculated the design shear requirement incorrectly. This was an issue for all ACI design codes.

Effect: Potentially incorrect design shear values when columns spanned multiple levels between braced levels.

 

ACI EFFECTIVE DEPTH FOR Vs CALCULATIONS*: In the determination of the reinforcement shear capacity, the effective depth did not consider the reinforcement diameter; only the clear bar cover distance was considered.

Effect: The effective depth used in the calculation of Vs was slightly larger than it should have been because it used the distance to the clear cover instead of the distance to the center of the bars. As a result the shear capacity used in design may have been slightly unconservative.

 

ACI GRAVITY COLUMN SHEAR DESIGN UNDER EARTHQUAKE FORCES*: In columns not designated as part of the seismic force resisting system with SDC D, E or F and whose factored gravity axial forces were greater than the specified by Section 21.13.4.3 of ACI 318-11, the referenced requirements of 21.6.4 and 21.6.5 were not checked.

Effect: The shear design of Gravity columns with SDC D, E or F may have been inadequate.

 

CONCRETE COLUMN: The shear force values for non-ACI codes reported in the View/Update dialog for the X- and Y-axis were switched.

Effect: The X-direction shear was listed for the Y-axis, and vice versa. This was a reporting issue only, in the View/Update dialog; the design was correct.

 

ACI CONTROLLING LOAD COMBINATION AND VU: In the Concrete Column Design report the Controlling Load Combination listed for Transverse Reinforcement was the load combination with the largest shear, not the load combination with the largest Demand/Capacity ratio.

Effect: The design was correct but the reported controlling load combination was incorrect if the controlling combination was some combination other than the one with the largest shear.

 

[656199] EN 1993-1-1 COLUMN SHEAR: In the Concrete Column design report a value of 0.0 was reported for applied shear in the minor axis.

Effect: This was a report only error; the design was correct.

 

RAM Concrete Shearwall

CONCRETE SHEAR WALL: When designing section cuts in shear wall, on rare occasions, the reported horizontal and vertical reinforcement ratio may have been negative and the section cut marked as failing, even though the actual provision was sufficient.

Effect: Negative sign on the vertical reinforcement ratio value may have caused the program to given an erroneous design error message. Note: Existing models may still exhibit this error. Review the Design Warnings, and if any value of Actual Ratio for the steel ratio is negative, delete all section cuts to clear the error, and reassign the section cuts.

 

RAM Frame – Analysis

WIND PRESSURE CALCULATION*: In the calculation of the coefficients used in the calculation of the wind pressures, some coefficients use the story building dimensions. When there was a partial level (such as a mezzanine) enclosed within the building beneath a story with a larger floor plan, the program used the partial level’s diaphragm dimensions rather than the building envelope dimensions (defined by the larger diaphragm dimensions above). Note: when there is a smaller partial level, the actual building envelope at that level is likely to be the same as the larger level above rather than the same as the smaller level.

Effect: Potentially incorrect coefficients were used in the calculation of wind pressure at levels where the diaphragm extents were less than those of the level above. This error, when it occurred, was almost always conservative. Note that after the pressures were calculated the program correctly applied those pressures to the building envelope, distributing the forces to the partial level, the level above and the level below as explained in the manual.

 

WIND LOADS ON SEMIRIGID DIAPHRAGMS*: Wind loads on semirigid diaphragms are applied as line loads on the windward and the leeward side of diaphragms. The program first looks for mesh points along slab edges, and then distributes the wind line load on such mesh points located along the edges. In some cases where the diaphragm mesh did not extended fully over to slab edge lines (because the option to Use Beams for Exterior Boundary was selected in Criteria – Diaphragm), the program may have failed to find mesh points along those edges, and hence, failed to apply the wind loads.

Effect: Wind loads on semirigid diaphragms may have been missed.

 

TRANSFER LOADS ON FRAME COLUMNS: Excessive gravity loads were applied to columns if the following conditions were met for the column: the column supported a Frame wall, and that wall supported Frame columns above. In this case, loads from the Frame columns above the wall were applied to both the wall and to the column below the wall instead of only applied to wall.

Effect: Such columns were designed for twice the gravity load than was actually applied at the floors above the wall.

 

SNOW LOADS ON TWO-WAY DECKS: The program miscalculated snow loads on two-way decks if it did not have a constant loading profile (i.e., snow drift). This impacted total gravity loads calculation on such diaphragms (used for P-Delta effects and notional loads) as well as gravity (snow) loading on two-way decks.

Effect: Total Snow drift loads used for P-delta and for Notional loads were not correct for the conditions indicated.

 

MERGING LOADS FROM PENTHOUSE LEVELS*: When upper levels are modeled without any frame members (such as for a simple mechanical penthouse roof), the program automatically merges the wind and seismic loads on those levels down to the level below so that no lateral loads are lost. This was only working correctly if the level below was a Rigid diaphragm.

Effect: If the diaphragm of the level below such levels did not have a Rigid diaphragm, the lateral loads were not merged down to that level, they were lost (not included in the analysis).

 

ASCE 7 STABILITY REPORT: If the analyzed seismic load case was ASCE 7-10 but the ASCE 7-05 option to generate the ASCE 7 Stability Report was selected (or vice versa) and the Importance Factor was greater than 1.0, the reported stability coefficients were not correct; they were off by the Importance Factor.

Effect: The reported ASCE 7 seismic stability coefficients were not correct if the seismic load case and the selected stability coefficient were not from the same version of ASCE 7, and the Importance Factor was greater than 1.0. The error did not occur if the load case and the Stability Coefficient code were from the same version of ASCE 7, nor did the error occur if the Importance Factor was 1.0.

 

BUILDING AND FRAME STORY SHEARS*: Building and frame story shear reports listed incorrect results for response spectra cases when all of the following conditions occurred:

  • The diaphragms were Semi-rigid or two-way decks

  • In the Criteria – Diaphragm command the option had been selected to Include Gravity Members in the analysis

  • Only gravity and dynamic cases were analyzed.

Note that if there was at least one seismic or wind load case included in the Analysis, the error did not occur.

Effect: Building and frame Story Shear reports listed incorrect results if all aforementioned conditions existed.

 

BUILDING AND FRAME STORY SHEARS*: Building and frame story shear reports listed incorrect results for response spectra cases when all of the following conditions occurred:

  • The diaphragms were Semi-rigid or two-way decks

  • In the Criteria – General command the option had been selected to Exclude BRB from Gravity Load Cases in the analysis

  • Only gravity and dynamic cases were analyzed.

Note that if there was at least one seismic or wind load case included in the Analysis, the error did not occur.

Effect: Building and frame Story Shear reports listed incorrect results if all aforementioned conditions existed.

 

SIDEPLATE CONNECTION WITH GEOMETRIC WARNINGS: If the beam and columns sizes produced warnings on geometric incompatibility for the SidePlate connection, the program continued the design, but produced incorrect results.

Effect: Design values calculated for the beam with SidePlate may not have been correct if geometric incompatibility was detected. The error did not occur if the sizes were compatible for the connection so there were no geometric incompatibility warnings.

 

HANGING COLUMNS UNDER TWO-WAY DECKS*: If hanging columns were attached to two-way decks, the reaction applied to the deck from the hanging column was incorrect.

Effect: For this unusual condition, incorrect loads were applied from hanging columns to diaphragms with two-way decks. The error was usually obviously large.

 

PSEUDO-FLEXIBLE DIAPHRAGMS: The Loads and Applied Forces report listed an incorrect value for the Total applied load on pseudo-flexible diaphragms.

Effect: This was only a reporting error. The values used in design were correct.

 

WALL SELF WEIGHT*: The program miscalculated wall self-weight if an opening inside the wall crossed the top edge of the wall. In this case, calculated line load (due to self-weight) was not correct (less than expected).

Effect: Missing load (wall self-weight) if a wall included an opening that crossed the top edge of the wall.

 

BEAM MOMENTS FOR RESPONSE SPECTRA CASE*: In the Member Forces report the reported beam moments for response spectra cases were not correct if rigid-end zones were specified and moments were reported at column face.

Effect: The reported Member Forces showed wrong values at the column face of dynamic moments for beams with rigid end zones. The defect did not occur if beam moments were shown at centerline. The values displayed on screen and shown in Analysis Results diagram were correct.

 

RAM Frame – Steel Standard Provisions

AS 4100-98 MEMBER DESIGN FORCES*: When checking the member design capacity, the design bending moments were not necessarily the maximum moments along the entirety of the member.

Effect: When checking the member capacity, AS 4100-98 Section 8.2 requires that design moments in the primary axes be the maximum along the entirety of the member. Where the maximum moments in the two axes were not at the same location, the design used the moments at one of the maximum locations in the design rather than combining the maximum moments at the different locations together with the axial load.

 

CHANNEL WEAK AXIS PLASTIC SECTION MODULUS*: If the weak axis plastic neutral axis fell within the web of a channel section, the weak axis plastic section modulus was calculated incorrectly.

Effect: Potentially incorrect capacities calculated for channels in weak axis bending.

 

MEMBER FORCES WITH SIDEPLATE*: If a member size was changed using the Assign Size command in RAM Frame on a Frame assigned to use the SidePlate connection, the subsequent analysis was not exactly correct because the points used in the SidePlate finite element model were not immediately updated when the assignment was made.

Effect: Calculated member forces may have been slightly incorrect if different sizes were assigned to frame members with the SidePlate connection. The error corrected itself if the model was subsequently run in one of the other design modules.

 

AISC ASD LOAD COMBINATIONS: Some of the AISC ASD load combination templates had an incorrect factor (1.0 instead of 0.60) on the Notional Dead Load in the 0.6D + 0.6ND + 1.0W or 0.6 + 0.6ND + 0.6W load combinations. The affected templates were: AISC360_05 ASD, AISC360_10 ASD, IBC06/ASCE7-05 ASD, IBC09/ASCE7-05 ASD, and IBC 2012 / ASCE 7-10 ASD.

Effect: When Notional loads were included in the combinations with the lateral load cases the factor on the Notional dead load was 1.0 instead of 0.6 for the load combinations and in the templates listed above. The error was slightly conservative, but would only impact the designs if wind uplift was the controlling load combination.

 

RAM Frame – Steel Seismic Provisions

JOINT CHECKS FOR RECTANGULR HSS COLUMNS: When a Joint Check was performed on a joint at a rectangular HSS column and the SidePlate connection had been assigned, some of the reported results were not relevant to the SidePlate connection and should not have been listed. Similarly, when a Joint Check was performed on a joint at a rectangular column and the SidePlate connection had not been assigned, some of the reported results were only relevant to the SidePlate connection and should not have been listed.

Effect: For joints at rectangular HSS columns, some joint code checks were performed and reported that were not relevant to the type of connection assigned to the joint.

 

BEAM SEGMENT J-END: The reported J-End coordinates for the controlling segments for shear and moment for beams were incorrect when the selected system unit was either SI or Metric.

Effect: Report error only, the reported J-End coordinate for the shear and moment sections of the design report was incorrect. The beam designs were correct.

 

BRBF AND SCBF COLUMNS WITH HORIZONTAL BRACES: Due to the complexity of multiple beams framing into a given side of a column, the program will not perform the Seismic checks on a column that has more than four Frame beams framing into it. When determining the number of beams framing into the column the program was erroneously including Horizontal Braces in this count, so even if there were four or fewer Frame beams framing into the column, if the sum of the number of Frame beams and Horizontal Braces exceeded four the program would not perform the BRBF and SCBF column checks. As a result, there were some erroneously reported values (e.g., zero axial load in the column).

Effect: Section F2 and F4 code checks for BRBF and SCBF columns supporting more than four horizontal braces and frame beams were not performed. Now the program ignores the number of Horizontal Braces, and will not perform the checks only if the number of Frame beams exceeds four.

 

RAM Foundation

FOUNDATION DESIGN *: Moments created by the shear at the base of the column were not added to the foundation design forces even if the option to "Include Moment Due to Shear in Column" was selected.

Effect: The moment due to the shear in the column was not considered in the footing design. This affected all design codes.

 

DEAD LOAD*: If the option to use Forces on Gravity Members From RAM Concrete was selected in Criteria – Forces, the Dead load was not included in the Foundation design in some cases.

Effect: Dead load may not have been considered in design. The error, when it occurred, was obvious in the reports.

 

MISSING LOADS FROM BRACES ON FOUNDATIONS*: If a foundation had been lowered using the Modify Footing Elevation command, and if that foundation supported a brace that spanned across multiple levels (it did not connect to any elements on the level immediately above the foundation), the loads from the brace were not included in the design loads on the footing.

Effect: Unconservative design in the rare case described above.

 

MISSING DYNAMIC LOADS*: If a foundation had been lowered using the Modify Footing Elevation command, loads from dynamic load cases were not included in the design loads on the footing.

Effect: Design did not include the dynamic loads if the footing had been lowered.

 

ISM / Structural Synchronizer

Significant time and effort was spent improving the performance of the interface between the RAM Structural System and ISM. These corrections improve the interoperability with Bentley products and third-party programs such as Revit and Tekla. Several defects were corrected, including the following:

 

CONCRETE COLUMN TIES: Column ties may have been missing in an export of multistory models for all floors except the first.

Effect: Concrete Column ties were missing; this could have had an impact on consuming applications that required the ties being present for drawing production.

 

TEE-SHAPED CONCRETE BEAMS: The ISM export of concrete T beam with flange beam set to have a calculated flange width and flange thickness equal to the deck thickness resulted in an ISM warning of "section not set" rather than exporting only the rectangular stem of the T beam (ISM can’t currently handle Tee-shaped concrete beams).

Effect: Resultant member in the ISM Repository appears as stick figure with no section assigned; consuming application may similarly only import the T beam as a line rather than with the correct section.

 

CANTILEVERS: Cantilevers sometimes did not import correct.

Effect: Cantilevers incorrect in the RAM Structural System model that required some effort to correct.

 

STUB CANTILEVER REACTIONS*: On export, the reactions for stubs was placed on the free end rather than the column connected end.

Effect: Reactions were assigned to the wrong end; this could have had an impact on consuming analytical applications that deal with steel members.

 

SLAB EDGES: For certain ISM imports where modelling originated from a free form modelling application such as Revit, Slab Edge sometimes exported into Ram Structural System extending to infinity.

Effect: Slab edges that required deleting and remodeling. Note: Care should still be taken when modelling slabs in Revit to have regions snap properly and avoid very thin slivers of slab and openings in the model.

 

 

Tags: RAM Structural System, release notes, 15.04

Appendix A: Analytical Insights - Technology Preview

$
0
0
Revision 2 posted to RAM | STAAD Wiki by Allen Adams on 2/24/2017 12:36:49 AM

Appendix A

Technology Preview – Analytical Insights

Icon

 

Description

 

Analytical Insights (AI) is a data analytics service for design engineering with the following objectives

      • Automating and increasing breadth of QA/QC

      • Practical engineering design with construction data

      • Institutionalized lessons learned to reduce design risks

      • Executive overview on design status and quality

 

To start the Analytical Insights Technology Preview, select the Bentley Cloud Services – Analytical Insights Technology Preview command.

 

AI enables you define custom engineering rules in addition to code prescribed rules for engineering design. AI also lets you merge construction data from various sources with the engineering model to offer create more practical designs.

 

In principle, AI implements the following workflow:

 

 

KPI stands for Key Performance Indicator.

 

An Engineering Manager can set up design rules online through the CONNECT portal. These rules will be shared across their entire organization. These rules specify properties of the structure along with permissible limits. For example, a rule might specify that the span to depth ratio for steel beams should not be less than 20.

 

An Engineer can upload a model from RAM Structural Systems to Analytical Insights by first exporting the RSS model to an ISM file format, via the ISM link, and then sending data to Analytical Insights through the AI Extractor.

 

Before launching Analytical Insights, a CONNECT project must be associated with the currently loaded RAM model (see chapter 4, "CONNECTED Project Association" for more information) and an ISM file must be created for the model (see chapter 3, “Integrated Structural Model (ISM) Link").

 

The AI Launcher will convert the ISM file to a cloud compatible format and then upload the model to Bentley CONNECT. After the upload completes, the AI launcher will invoke an internet browser session with the model link where you can set up design rules and perform KPI analyses.

 

CONNECT sign-in and CONNECT project assignment are requirements to utilize Analytical Insights.

 

    • Learn more about Bentley CONNECT from here

    • Learn more about sign-up information from here

 

You will find information on how to use Analytical Insights on the AI start page. Click the “Learn more about Analytical Insights” link to launch an interactive work flow diagram that explains the steps and results.

 

In future releases of Analytical Insights, the user will be able to compare a model with previous models present in an organization. The user will be able to apply filters like Type of Lateral Resistance, Year Built, Weights per Area, etc. and investigate design patterns and decisions made in previous projects.

 

Read more about Analytical Insights here.

Tags: RAM Structural System, release notes, 15.04, V15.04, Analytical Insights

Incorrect Snow Drift Loads on Two-Way Decks in RAM Concrete

$
0
0
Current Revision posted to RAM | STAAD Wiki by Karl G on 2/24/2017 4:12:05 PM

 Applies To 
 Product:RAM Concrete
First Affected Version:
 Found in Version:15.03.00.00
Released in Version:
 Area: Analysis
 Issue #:592301

Problem Description

Snow loads are applied incorrectly to two-way decks in RAM Concrete. All models with snow drift on two-way decks and analyzed in RAM Concrete are affected. Design of concrete beams, column, and foundations in those models are also affected if the gravity forces come from RAM Concrete.

Reason

The program uses the smallest drift magnitude over the entire drift polygon rather than using the three drift magnitudes that define the drift plane.

Solution

This issue is under review. The snow drift loads are processed correctly in RAM Frame. Converting gravity members to frame members and designing with force results from RAM Frame is a possible work around.

Tags: analysis, Active, design, RAM Structural System, known issue, defect, Ram Concrete, Unconservative

Minimum Reinforcement in Spread Foundation with Top and Bottom Reinforcement

$
0
0
Revision 1 posted to RAM | STAAD Wiki by Karl G on 2/24/2017 4:23:53 PM

 Applies To 
 Product:RAM Foundation
First Affected Version:
 Found in Version:14.06.00.00
Released in Version:
 Area: Design
 Issue #:617970

Problem Description

Foundations with top and bottom reinforcement and governed by the minimum reinforcement provision are under designed. Foundations with bottom reinforcement only are designed correctly.

Reason

In foundations with both top and bottom reinforcement, the program added the top and bottom reinforcement and applied the total area of steel to meet the minimum flexural reinforcement requirements in ACI 318 10.5.4, which refers to 7.12. The minimum flexural reinforcement requirement in 10.5.4 should be applied separately to the top and bottom reinforcement. This is clarified in ACI 318-14.

Solution

This issue is under review.

Tags: Active, design, RAM Structural System, foundation, RAM Foundation, ACI 318, known issue, defect, Unconservative

ACI 318 Shear Design of SMF Concrete Columns

$
0
0
Current Revision posted to RAM | STAAD Wiki by Karl G on 2/24/2017 4:57:27 PM

 Applies To 
 Product:RAM Concrete
First Affected Version:
 Found in Version:15.03.00
Fixed in Version:
 Area: Design
 Issue #:620612

Problem Description

Concrete columns of special moment frames were designed with an incorrect shear demand when there was no column on a level above.

Reason

Columns that are part of special moment frames must be designed for a shear demand associated with probable flexural strength (Mpr). The shear demand was calculated by summing Mpr and dividing by 2. This is a simplification that assumes that the column above and below have the same relative stiffness and half of the total moment is split to the column above and below. The division by 2 occurs even when there is no column above the level, which results in an unconservative.

Solution

We are working on a fix for this issue.

Tags: Active, design, Column, RAM Structural System, known issue, seismic, defect, Ram Concrete, Unconservative

ACI 318 Concrete Column Design Spiral Reinforcement Spacing

$
0
0
Current Revision posted to RAM | STAAD Wiki by Karl G on 2/24/2017 6:24:30 PM

 Applies To 
 Product:RAM Concrete
First Affected Version:
 Found in Version:15.03.00.00
Released in Version:
 Area: Design
 Issue #:626269

Problem Description

ACI 318-11 7.10.4.3 states that the clear spacing between spirals shall not exceed 3 in. This requirement was not checked by the program. Columns with spiral reinforcing may have been designed with a larger spacing and no design warning was produced. All ACI 318 codes were affected. 

Solution

A fix is in process and will be included in v15.05.00.

Tags: Spiral, Column, RAM Structural System, known issue, defect, Ram Concrete, Unconservative

RAM Steel Shear Design and Beams with Point Loads

$
0
0
Current Revision posted to RAM | STAAD Wiki by Karl G on 2/24/2017 6:37:07 PM

 Applies To 
 Product:RAM Steel
First Affected Version:
 Found in Version:15.03.00
Fixed in Version:
 Area: Design
 Issue #:635331

Problem Description

Some building codes, such as the Eurocode, require shear design checks at stations corresponding to the location of maximum moment. For some beams with point loads, a shear lower than the maximum shear may have been used in the design.

Reason

At point load locations, the shear just to the left of the point load is different than the shear just to the right of the point load. When calculating the governing shear, the program was looking at stations just to the right of the point load location only and not at stations just to the left. If the maximum shear was located just left of the point load, an incorrect and unconservative shear was used in the design.

Solution

Fixed in v15.04.00.

Tags: design, 15.04.00, RAM Structural System, Eurocode, Shear, known issue, defect, Unconservative, RAM Steel

Lateral Loads on Flexible/None Diaphragms Supported by Gravity Members Only

$
0
0
Current Revision posted to RAM | STAAD Wiki by Karl G on 2/24/2017 6:58:35 PM

 Applies To 
 Product:RAM Frame Analysis
First Affected Version:
 Found in Version:15.03.00
Fixed in Version:
 Area: Analysis
 Issue #:642195

Problem Description

Program generated lateral loads applied to diaphragms at the top story should be lumped to the story below when the diaphragm is defined as "Flexible/None" and the diaphragm is connected to gravity members only (no frame members). This was not done by the program and the generated lateral loads on the top level diaphragm were lost.

Solution

Fixed in v15.04.00.

Tags: analysis, Flexible, RAM Frame, 15.04.00, RAM Structural System, Diaphragm, known issue, defect, Unconservative, lateral

RAM Concrete Shear Wall Negative Reinforcement Ratio

$
0
0
Current Revision posted to RAM | STAAD Wiki by Karl G on 2/24/2017 7:12:06 PM

 Applies To 
 Product:RAM Concrete
First Affected Version:
 Found in Version:15.03.00
Fixed in Version:
 Area: Design
 Issue #:651534

Problem Description

In rare cases, the program may have reported negative horizontal and vertical reinforcement ratios. When this occurred, the program marked the section cut as failing when the reinforcement requirements satisfied code requirements.

Solution

Fixed in v15.04.00.

The issue may still occur in existing models. To resolve the issue in these models, delete and remodel all section cuts.

Tags: design, 15.04.00, RAM Structural System, reinforcement, known issue, defect, Ram Concrete, Shear Wall

Eurocode2 Concrete Column Design 0 Shear

$
0
0
Current Revision posted to RAM | STAAD Wiki by Karl G on 2/24/2017 7:23:11 PM

 Applies To 
 Product:RAM Concrete
First Affected Version:
 Found in Version:15.03.00
Fixed in Version:
 Area: Design
 Issue #:656199

Problem Description

In RAM Concrete Column, the program may have reported the shear in the minor axis as 0.0 when Eurocode2 was selected for the design code. This was a reporting error only. The program design was not affected.

Solution

Fixed in v15.04.00

Tags: design, Column, RAM Structural System, v15.04.00, Eurocode, Shear, known issue, defect, Ram Concrete

ACI 318 Shear Design of SMF Concrete Beams with Two-Way Decks

$
0
0
Current Revision posted to RAM | STAAD Wiki by Karl G on 2/24/2017 7:38:46 PM

 Applies To 
 Product:RAM Concrete
First Affected Version:
 Found in Version:15.03.00
Fixed in Version:
 Area: Design
 Issue #:641214

Problem Description

The design shear for concrete beams in special moment frames is calculated using the applied gravity loads (see ACI 318-11 21.5.4.1 and Fig R21.5.4). Gravity loads that are associated with two-way decks are ignored by the program when calculating the design shear.

Solution

This is a know limitation of the program that will be addressed in a future release.

Tags: design, RAM Structural System, beam, Shear, known issue, seismic, defect, Ram Concrete, Unconservative

ACI 318 SMF Joint Capacity Check Strong Column Weak Beam

$
0
0
Current Revision posted to RAM | STAAD Wiki by Karl G on 2/24/2017 7:48:43 PM

 Applies To 
 Product:RAM Concrete
First Affected Version:
 Found in Version:15.03.00
Fixed in Version:
 Area: Design
 Issue #:624602

Problem Description

In the joint capacity checks for SMF concrete columns, the program uses the moment capacity associated with the lowest axial force from all load combinations. This can be unconservative, however. For cases where the factored axial force is always large, the largest factored axial load will yield the lowest nominal moment capacity.

Solution

We are working on a fix for this issue.

Tags: Active, design, Column, RAM Structural System, known issue, Joint, seismic, defect, Ram Concrete, Unconservative

ACI 318 Shear Reinforcement SMF Concrete Columns

$
0
0
Current Revision posted to RAM | STAAD Wiki by Karl G on 2/24/2017 7:55:15 PM

 Applies To 
 Product:RAM Concrete
First Affected Version:
 Found in Version:15.03.00
Fixed in Version:
 Area: Design
 Issue #:626693

Problem Description

When determining Vc according to clause 21.6.5.2 of ACI318-11 (or earlier), the maximum value of the axial load on the column, considering all load combination is used against the prescribed limit. This may lead to Vc not being set to zero as required by the code.

Solution

We are working on a fix for this issue.

Tags: Active, design, Column, RAM Structural System, Shear, known issue, seismic, defect, Ram Concrete

ACI 318 Axial-Flexure Design of Large Columns with Large Minor Axis Moments and Small Major Axis Moments

$
0
0
Revision 1 posted to RAM | STAAD Wiki by Karl G on 2/24/2017 8:06:52 PM

 Applies To 
 Product:RAM Concrete
First Affected Version:
 Found in Version:15.03.00
Fixed in Version:
 Area: Design
 Issue #:640239

Problem Description

When designing large columns with a small major axis moment and a large minor axis moment, the phiMn values read from the P-M interaction surface may have been smaller than the correct value. This may have lead to column design failures that should not have occurred.

This applies to columns designed to ACI 318-11 and possibly previous ACI design codes.

Solution

We are working on a fix for this problem.

Tags: Active, design, Column, RAM Structural System, ACI 318, known issue, defect, Ram Concrete

AISC 360 F2 Design of Channels with Noncompact or Slender Webs and Flanges

$
0
0
Current Revision posted to RAM | STAAD Wiki by Seth Guthrie on 3/2/2017 11:20:54 PM

 Applies To 
 Product:RAM Steel
First Affected Version:
 Found in Version:15.03.00.00
Fixed and Released in Version:15.04.00.00
 Area: Design
 Issue #:562582 & 584248

Problem Description

Channels with webs or flanges that were either noncompact or slender were unintentionally designed and incorrect capacities were output by the program. A similar problem occurred with built-up channels unequal flanges that were compact.

Reason

AISC 360 Section F2 applies to channels with compact webs and flanges only. When the section was slender, the program should have output a slenderness warning and reported no design.

AISC 360 Section F12 applies to built-up channels with unequal flanges. To design these members, the buckling stress Fcr needs to be calculated by analysis. This calculation is beyond the scope of the program. When the flanges of channels were unequal, the program should have output a warning and reported no design.

Solution

The issue will be resolved in the release after v15.03.00. In the meantime, the user should use caution designing slender channel sections or built-up channels with unequal flanges in the Ram Steel Beam module.

Tags: slender, design, 15.04.00, RAM Structural System, known issue, Channel, defect, Unconservative, RAM Steel