Error getting a Ram Connection License with STAAD.pro SS5

$
0
0
Current Revision posted to Structural Analysis and Design - Wiki by Seth Guthrie on 7/28/2014 11:58:44 PM

  
 Applies To 
  
 Product(s):STAAD.pro, Ram Connection
 Version(s):V8i SS5 (STAAD.pro 20.07.10.64)
 Environment: N/A
 Area: Licensing Technical
 Original Author:Bentley Technical Support Group
  

 

 

 

 

 

 

 

Problem Description

When trying to access Connection design within STAAD.pro SELECT Series 5, you may be stopped with an error, No license for Ram Connection is available. Only simple Beam-Column connections available for usage."


Solution

Return to the STAAD.pro configuration options and on the Misc. Options tab, check the box for "User Ram Connection Product License".

If the option is already checked, try un-checking it, clicking Apply, then re-checking it and clicking Apply again followed by Accept.

If the problem persists, make sure that at least one RAM Connection license is available in the License Management Tool.

See Also

Tips for Using RAM Connection within STAAD.Pro [TN].

 