Rigid End Zones, Offsets and Hinges

$
0
0
Current Revision posted to Structural Analysis and Design - Wiki by Seth Guthrie on 7/21/2014 6:40:11 PM

  
 Applies To 
  
 Product(s):RAM Elements
 Version(s):Any
 Environment: N/A
 Area: Analysis
 Original Author:Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

When a member with a rigid offset includes an end release where is the hinge exactly?  

When a member is offset from its reference node, a rigid link is created between the original node which is unmodofied and the new member end position. The link is essentially a very stiff member with both ends fixed. If the member in Ram Elements is then hinged, the hinge occurs at the new end location of the member, before the rigid link.

Note, other Bentley Structural Analysis and Design products like STAAD.pro and RAM Structural System are similar in this regard.

See Also

Structural Product TechNotes And FAQs

External Links

Bentley Technical Support KnowledgeBase

Bentley LEARN Server

Comments or Corrections?

Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

 

Tags: Cardinal Points, RAM Elements, release, hinge, Offsets