Quantcast
Channel: RAM | STAAD | ADINA Wiki
Viewing all articles
Browse latest Browse all 8748

Blank Analyze Error Dialog during RAM Concrete Analysis

$
0
0
Revision 1 posted to Structural Analysis and Design - Wiki by kjgullerud on 7/17/2014 9:56:13 PM

  
 Applies To 
  
 Product(s):RAM Concrete
 Version(s):Any
 Environment: N/A
 Area: Analysis
 Subarea: 
 Original Author:Bentley Technical Support Group
  

 

 

 

 

 

 

 

Problem Description

A blank Analyze Error dialog is displayed when running the RAM Concrete Analysis:

Reason

The error is associated with corrupt settings in the Analysis Criteria dialog. See below. Common examples of bad settings include:

1. No solver selected.

2. Values of 0 for mesh parameters: Merge Node Tolerance, Max Distance Allowed Between Nodes, and Geometry Tolerance.

3. Large value for Minimum Number of Stations per Beam.

4. No Rigid End Zone option selected.

5. No Beam Torsion Stiffness option selected

Steps to Resolve

Redefine the settings with appropriate values. The program installed defaults can be found here:

RAM Concrete Defaults

Tags: analysis, Criteria, Analyze Error, Ram Concrete