Quantcast
Channel: RAM | STAAD | ADINA Wiki
Viewing all articles
Browse latest Browse all 8748

RAM SS - Foundation [FAQ]

$
0
0
Current Revision posted to Structural Analysis and Design - Wiki by Seth Guthrie on 6/30/2014 8:55:56 PM

  
 Applies To 
  
 Product(s):RAM Structural System
 Version(s):10.0 and later
 Environment: N/A
 Area: N/A
 Subarea: N/A
 Original Author:Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

Can mat foundations be designed in RAM Foundation?

Mat foundations cannot be designed in RAM Foundation. Mat foundations modeled in RAM Structural System can be exported into RAM Concept for analysis and design using the Ram Manager - Design - Ram Concept option or from within Ram Concept using File - Sync Ram Structural System - New from RAM SS.

The estimated perimeter of the mat must be modeled to encompass all of the supported columns and walls, and some concrete deck also needs to be assigned to the mat in Ram Modeler.

See the following web page for more on importing RAM Structural System models into RAM Concept:

RAM Concept-RAM Structural System Integration

How is 1/3 overstress accounted for?

The allowable soil stress assigned to the footing is constant for all combinations. So, there is no good way to accommodate 1/3 allowable overstress in the design if it pertains to some, but not all of the load combinations. 

We suggest incorporating the equivalent allowable overstress into the soil combos, by using reduced load factors on the combos with short duration loads.

Alternatively, the model could be designed twice; once with only gravity combos and a lowered allowable soil stress, once using gravity and lateral combos with the higher allowable.

How is uplift and overturning design done for spread footings?

See this blog post for details: Spread Footing Overturning and Uplift Checks in RAM Foundation

Why does the required area of steel increase when I use larger diameter bars?

In small foundations, the longitudinal bars are only partially developed at the critical moment location. When the program reports the area of steel required it is increasing the value reported by dividing by the percentage of full development. With smaller bars the development length is shorter so less net area of steel is commonly required.

This check can be circumvented by assigning the bars to be hooked (Assign - Geometry command)

The same rule also affects continuous footings in the transverse direction.

Are foundation design live loads reduced?

Yes, the Foundation module uses the same live load reduction values for columns.

For lateral columns, the foundation loads should match Ram Frame analysis results.

For gravity columns, the loads can be taken from either the Ram Steel analysis results or the Ram Concrete analysis results, both of which are subject to Live Load reduction. See RAM SS Analysis Types for reasons why those two results can differ. See RAMSS Two Way Decks for limits on LL reduction for two-way decks.

 

See Also

RAM SS Analysis Types

RAMSS Two Way Decks

Structural Product TechNotes And FAQs

Comments or Corrections?

Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

Tags: RAM Structural System, RAM Foundation