List of critical and high severity defects identified in STAAD.Pro V22 build 22.01.00.39

Issue IDTitleSeverity1st affected BuildFixed in Build
254014Error in deflection check calculation in all design codes2 - High20.07.00.0122.03.00.28
255402Wind Load on Double angle section2 - High20.07.00.0122.03.00.28
639514Incorrect Gust Factor Calculations for flexible buildings2 - High20.07.08.2222.02.00.26
1009580Error in the computation of Plastic Section Modulus (Zx) for User-Provided Table (UPT) wide flange shapes with unequal top and bottom flange dimensions defined in - (a) Wide Flange or (b) I-sections tables.1 - Critical20.07.00.0122.02.00.26
1012659Force Unit issue in Floor load with Reducible2 - High20.07.11.8222.02.00.26
1013172ACI 318-2014 - Mismatch in designed member number.2 - High21.00.02.3022.03.00.28
1017288Problem with AISC 360-16 Slenderness Calculation for HSS Sections2 - High21.00.02.3022.02.00.26
1019936Interaction ratio reporting error -IS 4562 - High20.07.00.0122.03.00.28
1022151AISC 360-16 LRFD - Incorrect Allowable Deflection 2 - High21.00.02.3022.02.00.26
1022412Wind Load: Difference in wind load generation with different input unit2 - High20.07.00.0122.05.00.131
1022413Earthquake workflow - Metric vs English2 - High20.07.00.0122.05.00.131
1022471ASCE 10-97 code check reports incorrect Tensile Capacity2 - High20.07.00.0122.04.00.40
1024419AIJ 2002 and 2005: Default value need to be set for MAIN 0 and TMAIN 0 2 - High21.00.01.1222.02.00.26
1024768Plate/Strips sections from the Dutch database are not designed by EN1993-1-1:2005 code2 - High20.07.00.0122.03.00.28
1025465Problem in tension column design in IS:456 Code with METHOD parameter2 - High20.07.00.0122.02.00.26
1026785Section forces mismatch between post processing and analysis output 2 - High21.03.00.14622.02.00.26
1027234Problem with βw Calculation for Unequal Angles During AISC 360-16 Code Check 2 - High21.00.02.3022.02.00.26
1028041IS 13920 2016 Column Design Issue2 - High21.03.00.14622.02.00.26
1028622Defect in shear area calculation for Built-up box section2 - High20.07.00.0122.02.00.26
1029712Russian Wind results incorrect with multiple analysis commands2 - High21.00.02.4322.02.00.26
1030139PLB value is not correct in the verification example “D9.B.5.1 Verification Example No. 1” in 22.01.00.39 STAAD.Pro CE2 - High22.01.00.3922.02.00.26
1030434AISC 360-16 Code Nominal Shear Strength of HSST Section is not calculated correctly 2 - High21.00.02.3022.02.00.26
1030667Problem with Deflection Check When LOAD SRSS GENERATE Command is Present2 - High20.07.09.1122.02.00.26
1030959Section Modulus Calculation for Stresses in AISC Unified Code Check is Incorrect For Single Angles2 - High21.00.02.3022.02.00.26
1038410Incorrect Base Shear reported since exceptions in clause 11.4.8 in ASCE 7-16/IBC 2018 are not considered in Static Seismic Load Generation Implementation2 - High22.01.00.3922.02.00.26
1040026Fa & Fv not correctly considered according to Tables 11.4.1/11.4.2 when not supplied as input to the program - IBC 2006/2012/20152 - High20.07.04.1222.02.00.26
1040154Tau-B Iteration Cannot Be Deactivated2 - High22.01.00.3922.02.00.26
1041545Design of Single Angles with full LTB restraint to AISC 360-05/102 - High20.07.09.3122.02.00.26
1042652Torsion reports as failure with Ratio of 1.0 per ACI 318-142 - High21.00.02.4422.02.00.26
1049980For calculating Bending Leg local buckling capacity for Unequal Angles as per AISC 360-10, the software is using length of the smaller leg as b 2 - High20.07.11.5022.03.00.28
1050840Pure torsion shear stress as per DG-9 is reported as zero for the AISC 360-05 code 2 - High20.07.10.6422.03.00.28
1052124Pure flexure shear stress is incorrectly calculated for angles designed as per AISC 360-05 and AISC 360-10 design codes, as a part of DG9 code check.2 - High20.07.10.6422.03.00.28
1052941Concentrated member moment incorrect results diagram2 - High21.00.02.4422.03.00.28
1057199The Cy value input for the User table Tee sections are not used by STAAD.Pro when designing as per the AISC 360-16 code2 - High21.00.02.4422.03.00.28
1058631AIJ 2002 and 2005 - Calculates incorrect Zx values for UPT-General section2 - High21.00.02.4422.03.00.28
1058714Wind Load Generation failing to load structure properly 2 - High20.07.04.1222.04.00.40
1059225Incorrect static wind loading as per Russian 2016 wind load code for Building Structures2 - High21.00.02.4422.03.00.28
1059242Russian static wind load exposure factor issue for SP 20 20162 - High21.00.02.4422.03.00.28
1061506Russian steel 2011 code issues2 - High20.07.11.5022.03.00.28
1061951Russian wind 2016 static load effective height ze.2 - High21.00.02.4422.03.00.28
1062460AIJ 2002 and 2005 - Incorrect Ix value used for UPT I section2 - High21.00.02.4422.03.00.28
1062461AIJ 2002 and 2005 - Calculates Incorrect Zx values for UPT Wide Flange Section2 - High21.00.02.4422.03.00.28
1062471AIJ 2002 and 2005 - Calculates Incorrect Bending Stress, Zy and Iw for UPT Channel Section2 - High21.00.02.4422.03.00.28
1062537AIJ 2002 and 2005 - Incorrect design results for UPT Tee Section2 - High21.00.02.4422.03.00.28
1062566AIJ 2002 and 2005 - Incorrect design results for UPT Asymmetrical Wide Flange Section2 - High21.00.02.4422.03.00.28
1063041IS800-2007 Bending capacity error for unsymmetrical sections2 - High21.00.02.4422.03.00.28
1065829Member Section Forces MX incorrect when concentrated moment applied to member.2 - High21.00.00.5722.03.00.28
1067696AIJ 2002 and 2005 - Tension Member Issue2 - High21.00.02.4422.03.00.28
1067883SNiP 1985 issues - Incorrect static wind load & OBLIQUE parameter2 - High20.07.04.1222.03.00.28
1068121Infinity unity ratio reported when tapered Square or I are designed as per AISC 360-16.2 - High21.00.02.4422.03.00.28
1068762Check Code All results for Deflection Check for AISC 360-16 Code are erroneous.2 - High21.00.02.4422.03.00.28
1069722Width to Thickness Ratio for Pipe Section as per AIJ2 - High21.03.00.14622.04.00.40
1070791Member Design results are changing when the model is reanalysed and members designed with IS:8012 - High22.01.00.3922.04.00.40
1070794Implement a warning saying that design of Class-4 built up sections is not supported by EN 1993-1-1:2005 code2 - High20.07.10.6422.04.00.40
1071967Incorrect Stress Reporting as per DG-9 when member is designed as per AISC 360 05/10 code2 - High22.01.00.3922.04.00.40
1072277AIJ 2002 and 2005 - Calculates incorrect Iw values for Wide Flange UPT section2 - High21.03.00.14622.04.00.40
1072280AIJ 2002 and 2005 - Calculates incorrect Zy and Iw values for UPT Channel section2 - High21.03.00.14622.04.00.40
1072281AIJ 2002 and 2005 - Calculates incorrect Zz values for UPT Tee section2 - High21.03.00.14622.04.00.40
1074884AISC 360-16 reports incorrect deflection check results2 - High21.00.02.4422.05.00.131
1075459Incorrect web class being reported for a tapered member designed using IS: 800-20072 - High20.07.11.5022.04.00.40
1077199Improper implementation of the Clause 6.1.4 of IS:13920-2016 for the code checking of Beam Members.2 - High21.03.00.14622.04.00.40
1080055Incorrect Moment capacity calculation as per AS4100-19982 - High20.07.11.9022.05.00.131
1081390Analysis fails to get cold-formed section property data name includes W2 - High21.00.02.4422.04.00.40
1081492Incorrect Tensile Member Design as per AS4100-1998.2 - High20.07.11.9022.05.00.131
1083183AISC 360-16 - LTB design of single angles about the principal axis.1 - Critical21.00.02.3022.04.00.40
1085903Beams having side face reinforcements – fail in design as per ACI 318-142 - High21.00.02.4422.05.00.131
1085969US Coldformed Channel with Lips sections added by user takes wrong properties2 - High20.07.04.1222.04.00.40
1086171Error in LTB Check as per Canadian S16-14 Code1 - Critical20.07.11.3322.04.00.40
1088695Incorrect location is taken for some members when cl. 6.2.1(7) of EN 1993-1-1:2005 is checked2 - High20.07.10.4122.05.00.131
1088980IS:456-2000 - Beam Design - Moment corresponding to SFACE and EFACE command is not correct2 - High20.07.11.4522.05.00.131
1089913US Coldformed Angle, AngleS, Zee, ZeeS, Hat and Pipe Sections added by user takes wrong properties2 - High20.07.04.1222.05.00.131
1090036Mass is not calculated correctly when floor diaphragm is assigned to nodes2 - High20.07.08.2222.05.00.131
1092819EC3: Incorrect Effective Length value for torsion and Total Torsion for Design are considered for code checking2 - High20.07.07.3222.05.00.131
1092854EC3: Incorrect design of members while checking for the Cl.EC-6.2.1(7) if ELB 1 is specified2 - High20.07.04.1222.05.00.131
1093056Unit conversion issue with IS:1893-2016 seismic parameter from Physical to Analytical mode.2 - High22.01.00.3922.05.00.131
1093383Incorrect Bending Capacity reported for Single Angle as per Canadian Steel Design Code1 - Critical20.07.11.3322.05.00.131
1094012Incorrect axial compression capacity being calculated as per IS 800 2007 (LSD)2 - High20.07.06.2322.05.00.131
1094895Adds MASTER NODE to diaphragm created in Physical modeler2 - High21.00.00.5722.05.00.131
1095083EC3: Incorrect calculation of 'c' for the depth to thickness ratio of Tee section for the section classification in EN 1993-1-1:20052 - High20.07.04.1222.05.00.131
1097343Calculation of Effective Slenderness ratio as per Section E5 is ignored for Single Angle Sections for AISC 360-2016 Code.2 - High21.00.02.4422.05.00.131
1098559Program reports zero capacities for small load values using CSA S16-01 code2 - High20.07.04.1222.05.00.131
1099476Incorrect Centre of Rigidity calculation when Rigid diaphragm is defined using JOINT option2 - High21.03.00.14622.05.00.131
1100275Advanced Cable Analysis - Error in the Section displacements - Y direction2 - High20.07.11.5022.05.00.131
1100975Slenderness failure is considered incorrectly in AISC 360-10 and 360-05 Codes2 - High20.07.09.3122.05.00.131
1101622Incorrect Cw Calculation for members with general UPT sections and/or any I-shaped sections for AISC 360-16 design2 - High21.00.02.4422.05.00.131
1101961Slenderness failure is considered incorrectly in NZS3404-19972 - High21.00.00.5722.05.00.131
1101995Slenderness failure is considered incorrectly in CSA S16-14 & S16-09 codes2 - High20.07.11.3322.05.00.131
1103365Incorrect Section Strength calculation for Semi-Compact section - IS 800 2007 LSD2 - High20.07.11.3322.05.00.131
1103377Incorrect section strength calculation for tapered I-section as per IS 800 20072 - High20.07.11.7022.05.00.131
1103936Incorrect effective property calculation for Z-section with lips as per IS 8012 - High22.01.00.3922.05.00.131
1103955Incorrect Design forces considered for symmetrical sections in IS 800-2007 LSD design2 - High20.07.11.7022.05.00.131
1106275Incorrect base Shear calculation for Colombian Seismic code NSR-102 - High20.07.10.4122.05.00.131
1107006Incorrect moment capacity for CLASS 4 Tee section per EC3 code2 - High20.07.04.1222.05.00.131
1110683Elastic section modulus is incorrectly calculated for I section with cover plates for AISC ASD (9th Edition) design1 - Critical20.07.11.9022.05.00.131
1110726Incorrect section modulus of wide flange with different sized Top & Bottom plates2 - High20.07.10.4122.05.00.131
A-487590Nonlinear Analysis - plate results reported as zero for model with multiple load cases2 - High22.01.00.3922.06.00.138
A-487732Incorrect Warping Constant used during selection of wide flange profiles as per AISC 360-162 - High21.00.02.4422.07.00.160
A-487738Incorrect design as per AS4100 for a braced physical member having analytical node at any quarter point along its length2 - High21.00.02.4422.06.00.138
A-487742Error in torsion design for beams per ACI 318-20112 - High20.07.11.5022.06.00.138
A-505266Incorrect Warping Constant used during selection of wide flange profiles as per CAN/CSA-S16-14 or CAN/CSA-S16-092 - High21.00.02.3022.06.00.138
A-506489Incorrect Warping Constant used during selection of wide flange profiles as per IS 800 2007 (LSD/ WSD)2 - High21.00.02.3022.06.00.138
A-511125Incorrect Warping Constant used during selection of Channel profiles as per EN 1993-1-1 2005 or BS EN 1993-1-1 20052 - High20.07.11.7022.07.00.160
A-515693Member assigned with MEMBER TENSION and subjected to axial tension - is designed as a compression member with NZS3404-1997 code2 - High21.00.00.5722.06.00.138
A-524650Member section displacement results do not account for lateral releases on members2 - High20.07.04.12Known Issue
A-533716The horizontal seismic influence coefficient (ALPHA) is incorrect for period from 0.1s to Tg as per GB50011-20012 - High20.07.06.2322.06.00.138
A-547383IS801 compression capacity check for multiple properties2 - High22.01.00.3922.06.00.138
A-554981NZS 3404:1997 slenderness for tension members2 - High21.00.00.5722.07.00.160
A-633034NZS 3404-1997 : Clause 5.12.22 - High21.00.00.5722.07.00.160
A-669073AISC 360-16: Warping constant is used in the calculation of Euler Buckling Stress for T & 2L Sections2 - High21.00.02.4422.08.00.175
A-698135SANS 10162-1 : UNT and UNB parameters2 - High20.07.11.3322.09.00.115
A-710597EN 1993-1-1: 2005 : Utilization ratio as per Eq.6.62 for Slender Tee section2 - High20.07.07.1922.08.00.175
A-716046EN 1993-1-1: 2005 : Shift of neutral axis for Slender Tee section2 - High20.07.07.1922.08.00.175
A-784278AISC N690 1984: Shear design for pipe sections2 - High20.07.06.2322.09.00.115
A-813848Unbraced length : UNF and UNL Parameters2 - High20.07.08.3222.10.00.153
A-817499EN 1993-1-1:2005 : LEG parameter for single angle profiles2 - High20.07.07.3222.11.00.156
A-852094AISC 360-16 : FY and FU not considered from assigned material2 - High21.00.02.4422.10.00.180
A-865805Incorrect ELFP Torsional Moment : Optional Load Factor Multiplication2 - High22.01.00.3922.10.00.180
A-865842AISC 341-16 : Incorrect Seismic Classification for Custom Steel2 - High22.01.00.3922.10.00.180
A-935629AISC 360-16: SGR parameter2 - High21.00.02.4422.12.00.142
A-969825AISC 360-10/05 : Combined flexure and tension2 - High21.00.02.4422.12.00.142
A-973697AS4100-1998 : Moment modification factor2 - High20.07.11.90Known Issue
A-1003677NZS-3404-1997 : Physical member design2 - High21.00.00.57Known Issue
A-1005695NZS-3404-1997 : Analytical Member Design2 - High21.00.00.57Known Issue
A-1032348AISC 360-16 and BS5950 Pt 1 : Incorrect shear capacity parallel to the flanges for Double Channel profiles 2 - High21.00.02.30Known Issue
A-999611Incorrect Time History analysis results with a Harmonic Ground motion 2 - High20.07.04.1222.12.00.142
A-1073141IBC 2012/2015/2018: Failure to process negative accidental eccentricity factor in Response Spectrum Analysis 1 - Critical20.07.11.33Known Issue