Revision 1 posted to Structural Analysis and Design - Wiki by SteveCrabtree on 6/11/2014 9:17:44 PM
Applies To | |||
Product(s): | ISM Revit plug-in | ||
Version(s): | 08.11.09.216 | ||
Environment: | N\A | ||
Area: | Import/Export | ||
Subarea: | N\A | ||
Defect Number: | 93743 | ||
Original Author: | Steve Crabtree, Bentley Technical Support Group | ||
Defect Description
Importing certain models imported into Revit Structure sometimes causes an "Analytical Edge can't have a zero length error." when the Revit model is regenerating after the import is finished. This causes the model creation to fail.
Steps to Reproduce
- The error is inconsistant from model to model and is hard to reproduce with other models.
Workaround
The repository can successfully be imported into Revit if the floor surface members are rejected in Structural Synchronizer before importing the repository into Revit Stucture.
Follow these steps to reject the floor surface members.
- Use the New From Repository command as normal in Revit.
- When the repository opens in Structual Syncronizer sort the list so you can see all of the floor Surface Members in the table.
- Pick the check box of the first surface member and while holding the Control key select the last surface member in the list.
- Click the Reject button below the table.
- Review the list and also reject any table decks that appear in the list.
- Update the Revit model
See Also
XXXXXXX(Add links as needed for other relevant Be Communities content.)XXXXXXX
Tags: Import/Export, 08.11.09.216, ISM Revit plug-in, STAAD, SELECTsupport