Ram Elements - Distributed Load errors

$
0
0
Current Revision posted to Structural Analysis and Design - Wiki by Seth Guthrie on 4/14/2014 10:54:34 PM

  
 Applies To 
  
 Product(s):RAM Elements
 Version(s):11.0 or later
 Environment: N/A
 Area: N/A
 Subarea: N/A
 Original Author:Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

How can I resolve an analysis warning related to Distributed Loads?

During analysis, the follow error or similar can occur:

[Warning] Distributed load "1" in member "1" at load condition "DL=Dead Load" is zero, it will not be considered during the analysis.

When loads are generated by the program from areas or from importing from RAM Structural System, in particular, you may end up with loads that are defined (they have a direction and a category), but the magnitude is zero. It’s also possible for the user to start entering loads but then never enter any magnitude.

To fully correct the issue, the member loads spreadsheet for the load in question needs to be cleaned up so that load directions and categories are only defined when the load magnitude is > 0. Be aware this spreadsheet is wide to accommodate multiple line loads per member and the problem may not be for the first load.

See Also

RAM Elements Load Combos FAQ

Structural Product TechNotes And FAQs

External Links

Bentley Technical Support KnowledgeBase

Bentley LEARN Server

Comments or Corrections?

Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

 

Tags: RAM Elements, Distributed load

Viewing all articles
Browse latest Browse all 8748

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>