Master/Slave Command and Rigid Links

$
0
0
Current Revision posted to RAM | STAAD Wiki by Sye on 1/24/2022 9:12:01 PM

  
 Applies To 
  
 Product(s):STAAD.Pro
 Version(s):All
 Environment: N/A
 Area: General
 Subarea: General FAQ
 Original Author:Bentley Technical Support Group
  

I want to use the Master/slave command to model a rigid diaphragm in STAAD.Pro 2001. The problem is two columns separated by 40 ft. One column goes from joints 1 to 2 and the second column goes from joints 3 to 4. I wish to have a rigid link between joint 2 and joint 4. The program gives an error of multiple structures. What additional connections do I have to do to tie these joints together?

You may ignore the multiple structures/disjointed structures warnings if the two columns are connected through master/slave specifications. The software mentions that as part of the warnings itself. 

Master/Slave nodes are now labeled as Control/Dependent nodes in STAAD.Pro CONNECT Editions (22.xx.xx.xx) 

Tags: Master/Slave Command, rigid links