Current Revision posted to RAM | STAAD | OpenTower Wiki by Carlos Perez on 3/12/2021 11:42:52 PM
RAM Elements CONNECT Edition v16.03.00.101 Release
Notes – Updated March 2021 (under construction)
This is a patch for v16.3 release.
Resolved Issues:
- Wall modules tolerance issue for stresses calculated for integrated mode. This is fixed now and stresses from integrated mode are calculated correctly.
- Vertical reinforcement development length was included for shear walls in the Masonry Design module.
- ACI 318-11 incorrect shear strength ratio for circular concrete members. This is fixed now and critical stations and ratios are determined properly.
- Tilt-Up Wall module using simplified analysis for walls with openings was returning incorrect wall segments gross areas. This is fixed now and simplified analysis works correctly.
- AISC 360 was reporting incorrectly the length used to calculate the maximum slenderness limit in tension. This is fixed now and the length is reported as the member length.
Tags: CONNECT Edition, RAM Elements, tilt-up wall, AISC 360, Masonry Wall