Ram Connection for Ram SS Load Combinations

$
0
0
Revision 1 posted to RAM | STAAD | OpenTower Wiki by Seth Guthrie on 2/12/2021 11:23:53 PM
 Applies To 
 Product(s):RAM Connection, Ram Structural System
 Version(s):13.*, 17.*
 Area: Modeling; Design; General

What Load Combinations are passed from RAM Structural System to Ram Connection?

When Ram Connection for RAM SS is launched the program pulls the load combinations from Ram Frame Steel - Standard Provisions. Combinations from the Ram Frame - Steel - Seismic Provisions mode are also imported when that mode is current (green light for model status).

The user can override this with the Load Combinations ribbon menu dialog box launcher as indicated below.

If this option is unchecked, then Load Combinations need to be added within Ram Connection using Add/edit or Generate in the same ribbon menu.

Why do I get an error, "None load combinations could be read from the model."

Since the program is trying to pull the combinations from RAM Frame, this error will occur for all gravity models that do not have any Ram Frame combinations defined. To proceed in such a model, uncheck the option to "Include RAM Frame - Steel Provisions Mode load combinations as noted above, then manually define or generate new load combinations. 

See Also

RAM Connection Capabilities and Modeling FAQ

RAM Elements Load Combos [FAQ]

[[Ram Connection Seismic Provisions Settings]]

[[Connections for Gravity Members are Designed for Zero Force]]

Troubleshooting Errors when Assigning Connections

    

Tags: RAM Structural System, RAM Connection, load combinations

Viewing all articles
Browse latest Browse all 8748

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>