Ram Connection Anchor Forces Legend Reversed

$
0
0
Current Revision posted to RAM | STAAD | OpenTower Wiki by Seth Guthrie on 12/1/2020 4:13:05 PM
Applies To
Product(s):RAM Connection
Version(s):9.1.0.101
Environment: N/A
Area: Report

Problem Description

In the design report for base plates with anchors, near the end of the report is a section called "Max compression and tension" - "Base plate Anchors tension" with a graphic and a legend summarizing the anchor forces. 

The color legend on this graphic is reversed, blue should be at the bottom, and dark red should be at the top.

The values for anchor tension and the columns of the anchor circles is correct only if the legend is flipped.

Solution

The issue is corrected in the current version of Ram Connection.