Quantcast
Channel: RAM | STAAD | ADINA Wiki
Viewing all articles
Browse latest Browse all 8748

ACI 318 Effective Depth Coupling Beam Design

$
0
0
Revision 3 posted to RAM | STAAD Wiki by Seth Guthrie on 10/10/2019 3:42:57 PM
 Product(s):RAM Concrete Shear Wall
 First Affected Version:
Found in Version:15.00.00.00
Fixed in Version15.04.00.00
 Environment:N/A
 Area:Design
 Subarea:N/A
 Defect Number:355889

Problem Description

When calculating shear capacity of coupling beams, the program uses an effective depth of 0.8 x the beam height. The effective depth should be calculated using a strain compatibility analysis and represent the distance from the extreme tension fiber to the centroid of the tension reinforcement.

Reason

The use of 0.8xbeam depth follows from ACI 318-11 11.9.4. This is appropriate for walls but may not be appropriate for coupling beams.

Solution

In a future release, the effective depth will be calculated as the distance to the centroid of the tension reinforcement.

Tags: Active, design, Coupling Beam, RAM Structural System, ACI 318, known issue, fixed 15.04, defect, Ram Concrete, Shear Wall

Viewing all articles
Browse latest Browse all 8748

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>