Applies To | |||
Product(s): | RAM Structural System | ||
Version(s): | 14.05.00.00 or later | ||
Environment: | N/A | ||
Area: | Files | ||
Subarea: | N/A | ||
Original Author: | Bentley Technical Support Group | ||
How can I decouple or unlink a Ram Concept file that is part of a Ram Structural System file?
- Open the Ram SS model in Ram Manager
- Open the Design - Ram Concept window and note the Last saved in Concept time for the specific level of interest.
- Navigate to the RAM SS working directory (default here: C:\ProgramData\Bentley\Engineering\RAM Structural System\Data\Working)
- Locate the specific Concept file you want. The file name will be same as ram model with .cpt###E at the end. Check the saved time and compare to the information seen in Ram manager to make sure you have the right one.
- Copy the file to the clipboard and paste a copy in another location outside of the working folder
- Rename the file, changing the extension from .cpt###E to .cpt.
- Then open the copy in Ram Concept normally.
How can I delete a Concept file inside of a RAM SS file so that I can start over?
- Open the Ram SS model in Ram Manager
- Open the Design - Ram Concept window and note the Last saved in Concept time for the specific level of interest.
- Navigate to the RAM SS working directory (default here: C:\ProgramData\Bentley\Engineering\RAM Structural System\Data\Working)
- Locate the specific Concept file you no longer want. The file name will be same as ram model with .cpt###E at the end. Check the saved time and compare to the information seen in Ram manager to make sure you have the right one.
- Delete the file from the working folder
- Restart the Design - Ram Concept command in Ram Manager and you should now be able to start over with that level.
- Use the "Copy from existing Story data" option if you want to recover information from another story, otherwise check the settings and click OK.
WhenIopenaConceptfilethatwaspreviouslylinkedtoaRamStructuralSystemmodelIgetamessagethatthelinkwillbebroken.Howcanitbefixed?
IftheassociatedRAMSSmodelisdeleted,renamedormovedthenyouwillgetamessageindicatingthatthelinkmustbebroken:
Thisalsohappensifthefilesaretransferredtoanothercomputerandnolongerhavethesamerelativedirectorypaths.
Tofixtheissue,simplyreimporttheRAMSSfileintoConceptusingFile-SyncRamStructuralSystem-Import....
ThenusetheMergeoptionwhenpresented:
SelecttheappropriateRAMStructuralSystemmodelandstory.
Whenimportingbesuretouncheckanyitemsthatshouldnotbeupdated.Typicallywesuggestnotre-importingtheslabs,beamsoropeningssincethoseobjectsareoftenadjustedinConceptaftertheinitialimport.
See Also
Structural Product TechNotes And FAQs
Comments or Corrections?
Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!