Quantcast
Channel: RAM | STAAD | ADINA Wiki
Viewing all articles
Browse latest Browse all 8748

Deflections with Full E and I values

$
0
0
Current Revision posted to RAM | STAAD Wiki by Sye on 1/9/2019 1:19:05 AM

Applies To
Product(s):STAAD.Pro
Version(s):ALL
Environment: ALL
Area: Analysis
Subarea: DIRECT Analysis
Original Author:Sye Chakraborty, Bentley Technical Support Group

In a DIRECT ANALYSIS, are the beam deflections for serviceability checks computed using the unreduced E and I values?

By default STAAD uses the reduced E and I for carrying out the beam deflection checks. However in the section 5.37.5 of the Technical Reference Manual ( titled Direct Analysis ), you will find mention of a parameter named REDUCEDEI which can be set to a value of 0, for the full E and I to be considered for computing section displacements.

Tags: sections displacements, direct analysis, reduced E and I, deflection, full E and I