Current Revision posted to RAM | STAAD Wiki by Sye on 8/30/2018 1:40:27 AM
Applies To | |||
Product: | STAAD Foundation Advanced | ||
First Affected Version: | 08.04.00.21 | ||
Found in Version: | 08.04.00.21 | ||
Fixed and Released in Version: | 08.04.01.24 | ||
Environment: | All | ||
Area: | Installation | ||
Severity: | High | ||
Issue #: | #920928 |
Problem Description
If version 8.04 is installed over the prior version 8.03, then an error may occur trying to analyze a mat foundation model.
SProStaadFdn.exe - System Error
---------------------------
The code execution cannot proceed because Bentley.Structural.MathLib.dll was not found. Reinstalling the program may fix this problem.
The same issue may also occur if installation is done through the Auto-Update facility of the CONNECTION Client
Solution
The problem will be fixed with the next release of the installer. Until then, uninstall the program and reinstall 8.04 again.
Or copy Bentley.Structural.MathLib.dll
- From Folder: C:\Program Files (x86)\Bentley\Engineering\STAAD Foundation Advanced\OSOEM\
- To Folder: C:\Program Files (x86)\Bentley\Engineering\STAAD Foundation Advanced\SProEngine\
The problem has been addressed in the version 08.04.01.24.
Tags: installation, STAAD Foundation Advanced, known issue, defect, Bentley.structural.mathlib.dll