Current Revision posted to RAM | STAAD Wiki by Seth Guthrie on 8/7/2018 4:53:35 PM
The following issues have been addressed in RAM Connection V8i 07.03.01.30:
- Fix base plate demand for negative moments
- Fix weld access holes drawing and data report
- Fix shear plate maximum length reference
- Fix moment demand for BEP to account axial force
- Fix optimized plate thickness for the gusset plate connection
- Fix short side of the HSS when checking the minimum wall thickness
- Fix smart Fixed Biaxial Base Plate optimization
- Error in the Bending at Bolt Line check for extended shear plates
- Fix elastic weld demand
- Fix Optimized plate thickness for the gusset plate connection
- Fix print to File option name error while saving
Tags: release notes, RAM Connection