RAM Connection CONNECT Edition v12.0.1 Release Notes

$
0
0
Revision 1 posted to RAM | STAAD Wiki by Carlos Perez on 8/1/2018 9:23:00 PM

RAM Connection CONNECT Edition v12.0.1 Release Notes – Updated August 2018

Resolved Issues:

  • AISC chevron connection was showing an “Internal error” message as there were some glitches during its optimization. This is fixed now.
  • EN base plate connection assignation was slow for some particular cases. Base plate templates have been changed to always use the “Consider Compatibility Option” to reduce the assignation time.

  • AISC moment End Plate template has some invalid configurations when a haunch was included. Templates are now fixed and show just valid configuration options regardless the existance of a haunch.

  • Consider friction between base plate and support was causing an “Object of a reference” error due to a wrong base plate analysis for a tension only case. This is fixed and the friction is considered correctly regardless the base plate analysis.

  • AISC directly bolted connection for braces was incorrectly considering tension in the tension and shear interaction for slip critical bolts. Now tension is never considered as bolts in this connection type act just in shear.

  • Horizontal bracing connections were crashing for seismic loads. This was fixed and now all horizontal bracing connections are designed properly regardless the load type.