Current Revision posted to RAM | STAAD Wiki by Seth Guthrie on 5/31/2018 6:35:49 PM
Applies To | |||
Product: | RAM Connection (Ram Modeler) | ||
First Affected Version: | 12.00.00.31 (15.08.00.37) | ||
Found in Version: | 12.00.00.31 (15.08.00.37) | ||
Fixed in Version: | |||
Environment: | All | ||
Area: | Import/Export; File | ||
Issue Number: | 884969 |
Problem Description
There is a problem with Ram Connection 12.0 integration with RAM SS (Ram Modeler version 15.08).
1.Take any RAM SS model
2.Go to Ram Connection
3.Make any change in RAM SS (add a column, delete a beam, change a member size, etc)
4.Reopen Ram Connection - changes in step 3 are not there.
Depending on the type of change you can get an error, e.g.
"Node [30]" does not exist. Error at N1: Initial node
When a connection was assigned to a node /member that was deleted.
The geometry may also looks all wacky (spider web) or all members can disappear.
Reason
This is a new problem being corrected for the next release of Ram Connection.
Solution
Purge the model of the file.rcsx file and start over. To do this:
- Rename the file.rss to file.zip.
- Open the .zip archive.
- Locate the file.rcnx file and delete it.
- Rename the file back to file.rss and reopen it in Ram Manager.
Or revert to Ram Connection 11.2.
Tags: RAM Connection, First 12.00, known issue, defect