EC2:2004

$
0
0
Current Revision posted to Structural Analysis and Design Wiki by Sudip Narayan Choudhury on 9/16/2013 8:22:17 AM

EC2:2004

ThiscontainsFAQson

  
 AppliesTo 
  
 Product(s):STAAD.Pro
 Version(s):All
 Environment: N/A
 Area: Design
 Subarea: ConcreteDesigntoEC2:2004
 OriginalAuthor:BentleyTechnicalSupportGroup
  

 

 

 

 

 

 

 

 


 

1.WhenIrunthebeamdesigninEC2:2004thedesignabortswiththefollowingmessage:

Member10:Axialforcetoolarge.Beamdesignnot
appropriate.

Member10:Failedtensioncalculationsforhoggingat0.727m.Designnotpossible...

 WhatcanIdotoavoidthismessageandhavetheprogramdesignthemember?

 

Whenthebeammembersaresubjectedtoaxialforcesthe EC2:2004 implementationchecksitaccordingtoclause4.3.1.2(6)ofDDENV1992-1-1:1991,whichstatesthefollowing:

"Intheanalysisofacross-sectionwhichhastoresistbendingandonlyasmalllongitudinalforce,theeffectof
thelongitudinalcompressiveforcemaybeignoredifitdoesnotexceed0.08fcktimesthecross-sectionalarea".

Thisclauseischeckedbytheimplementationwhenanyoneoftheanalyticalmembersformingtheparticular
physicalmemberissubjectedtocompressiveaxialforces.Themessageisdisplayedwhentheaxialforceexceedsthelimitsetbythe code.