Blank Analyze Error Dialog during RAM Concrete Analysis

$
0
0
Current Revision posted to RAM | STAAD Wiki by Seth Guthrie on 2/21/2018 5:18:04 PM
 Product(s):RAM Concrete
 Version(s):Any
 Area: Analysis

Problem Description

A blank "Analyze Error" dialog is displayed when running the RAM Concrete Analysis. In some circumstances it can also result in "Analyze Error 4"

  or 

Note, Analysis Error 4 with additional details such as "Invalid Distance between nodes..." is another matter and happens when the program cannot mesh the model to the current geometry. For tips on resolving that see: RAM Meshing and Segmentation

Reason

The error is associated with corrupt settings in the Analysis Criteria dialog. See below. Common examples of bad settings include:

1. No solver selected.

2. Values of 0 for mesh parameters: Merge Node Tolerance, Max Distance Allowed Between Nodes, and Geometry Tolerance.

3. Large value for Minimum Number of Stations per Beam.

4. No Rigid End Zone option selected.

5. No Beam Torsion Stiffness option selected

Steps to Resolve

Redefine the settings with appropriate values. The program installed defaults can be found here:

RAM Concrete Defaults

RAM Meshing and Segmentation