Current Revision posted to RAM | STAAD Wiki by Seth Guthrie on 11/22/2017 6:24:49 PM
Product(s): | RAM Structural System; Ram Steel Column | ||
First Affected Version: | 14.06.02.00 | ||
Found in Version: | 14.06.02.00 | ||
Fixed and Released in Version: | 14.07.00.05 | ||
Environment: | N/A | ||
Area: | Design | ||
Defect Number: | 119978 |
Description
When performing Process - Design All in the Ram Steel Column module in version 14.06.02.00 (x32 or x64) a crash, Runtime Error!", may occur part way through the process:
Steps to Reproduce
The problem occurs in the base plate design process for columns that set upon the slab with no beam or column or wall below. It only happens in version 14.06.02.00 not prior versions. The defect was corrected in version 14.07.00.05.
Solution
The problem is corrected in version 14.07.00.05.
Alternatively, add a beam below the columns that do not align to columns or walls below.
Tip - Use the Options - Reference Layouts Types so that you can see the column above while modeling beams on the level below.
Tags: Column, RAM Structural System, crash, 14.07.00, Transfer, First 14.06.00, known issue, defect, SELECTsupport, RAM Steel