Current Revision posted to RAM | STAAD Wiki by Seth Guthrie on 10/13/2017 4:08:50 PM
Applies To | |||
Product: | RAM Concrete | ||
First Affected Version: | 15.05.00 | ||
Found in Version: | 15.05.00 | ||
Fixed in Version: | |||
Area: | Results; Graphics | ||
Issue #: | 744552 |
Problem Description
In v15.05.00.41, the shear wall stresses in the Concrete Shear Module - View/Update dialog cannot be viewed even when the Ram Frame Analysis is set to store wall stresses and a specific cross section is selected.
The buttons to select stress type are clickable, but no coloring or meshing occurs. It calculates the stresses because the color scale on the V/U dialog shows values but there no changes in the 3D view.
Other graphical anomalies may also occur when attempting to show the stresses.
Solution
We are working on a fix for this issue.
Tags: Active, RAM Structural System, graphics, results, known issue, First 15.05.00, Shear Wall