Quantcast
Channel: RAM | STAAD | ADINA Wiki
Viewing all articles
Browse latest Browse all 8748

Ram Connection Does Not Launch from Ram Manager

$
0
0
Revision 1 posted to RAM | STAAD Wiki by Seth Guthrie on 8/22/2017 5:01:16 PM
 Applies To 
 Product:RAM Connection for RAM SS
First Affected Version:11.01.01.240 (15.05.00)
Found in Version:11.01.01.240 (15.05.00)
 Fixed in Version:
Environment:x32 and x64
 Area: Import/Export
 Issue Number: 7

Problem Description

If RAM Connection CONNECT Edition version 11.01.01.240 (x32) is installed, it cannot be launched from Ram Structural System CONNECT Edition (x64) via the Ram Manager menu or button. 

Reason

A new defect to be corrected in the next build.

Solution

Problem to be corrected in the next build after 11.01.01.240.  Until then, if integration with Ram Structural System is required, uninstall Ram Connection 11.01.011.240 and reinstall an older version (e.g. 11.01.00.227). 

Tags: Import/Export, RAM Structural System, RAM Connection, known issue, defect, First 11.01.01