Applies To | |||
Product(s): | Structural Synchronizer | ||
Version(s): | SS5 and later | ||
Environment: | N/A | ||
Area: | Installation | ||
Problem Description
If the Structural Synchronizer SS5 is installed along with ProjectWise Navigator, then the ProjectWise Log in dialog will be presented by default when starting the Viewer, Editor etc. When ProjectWise Navigator is not installed this option will not appear.
To view an ISM repository from the local drive, simply click [Cancel] and the normal Windows file browser will appear.
Solution
To completely disable the ProjectWise integration, locate the file Structural synchronizer.exe.config normally located in the folder:
C:\Program Files\Bentley\Engineering\StructuralSynchronizer V8i SS5\Bin\Synchronizer
and edit the file with any text editor (e.g Notepad).
Within the file, look for the line that says:
<add key="disableProjectWiseIntegration" value="false" />
and change the "false" to "true". Then save and close the file.
See Also
Integrated Structural Modeling Home