Current Revision posted to RAM | STAAD Wiki by Karl G on 7/14/2017 5:31:33 PM
Reported Major and Minor Shear Values RAM Concrete Column | Product(s): | RAM Concrete Column | |
First Affected Version: | |||
Found in Version: | 15.04.00.00 | ||
Fixed in Version | 15.05.00.00 | ||
Environment: | N/A | ||
Area: | Report | ||
Subarea: | N/A | ||
Defect Number: | 658764 |
Problem Description
When EC2 is selected as the design code, the critical major and minor shear forces (VEd) listed in the Design Report may not be the actual critical shear forces used in the design. This is a reporting issue only. The correct critical shear forces are used in the design and can be viewed in the View/Update dialog.
Reason
Only the first two load combinations are considered for the reported critical shear forces. When another load combination controls, the reporting error will occur.
Solution
Fixed in version 15.05.00.
Tags: reports, RAM Structural System, 15.05.00, known issue, Column Design, Ram Concrete