Current Revision posted to RAM | STAAD Wiki by F_Diego on 6/1/2017 8:35:25 PM
RAM Connection CONNECT Edition v11.1.0 Release Notes – Updated May 2017
Enhancements:
- IS 800:2007 Indian steel design standard for connection design.
- RAM Connection now includes Bentley CONNECT Advisor v10.0.2 which is a CONNECT service enabling Bentley users to have real time access to LEARN content, recommendations for more productive workflows and the ability to embed an Expert Engineer to their CONNECTED project.
- Small improvements to the design reports for better reading.
- Update to Structural Synchronizer (ISM) 6.0.
Resolved Issues:
- A miscalculation of the gusset buckling Whitmore capacity when the brace formed a small angle with the beam has been corrected.
- The effective length factor “K” was being calculated incorrectly for the Whitmore buckling code check in gusset connections.
- The length used to calculate web crippling in Gusset connections used a unitary equivalent length when Design Guide 29 states the actual lengths have to be used. This has now been updated to comply with the aforementioned guide.
- The prying effects calculation for Cap Plates, erroneously used the beam flange thickness instead of the cap plate thickness. This has been corrected.
- For the calculation of normal stresses in a beam-to-gusset interface, an equation from a different reference was being used. The application has now been updated to use the equation in Design Guide 29.
- The beam web thickness check for Single Plate connections with a skew angle, has been eliminated by recommendation of the AISC Solution Center.
- For EN 1993 connection design, the software followed a criterion only applicable for tension/compression members for the bolt pitch (or gage). Now it follows BCSA recommendations the same.
- The Cap Plate web crippling check followed the same procedure for AISC 360-05 and AISC 360-10. This has now been corrected to follow the correspondent method, since it has changed from the 2005 to the 2010 edition.
- A new warning was added for Stiffened Seated connections with HSS columns, in which the length of seat plate exceeds the flat width of the section.
- Other several minor fixes.
Tags: release notes, RAM Connection