Quantcast
Channel: RAM | STAAD | ADINA Wiki
Viewing all articles
Browse latest Browse all 8748

Time history displacements reported in the .TIM file at a given time step were for the subsequent time step

$
0
0
Revision 1 posted to RAM | STAAD Wiki by Sye on 5/23/2017 7:05:10 PM

 Applies To 
 Product:STAAD.Pro
First Affected Version:
 Found in Version:20.07.11.82
Released in Version:20.07.11.90
Environment:All
 Area: Post Processing
Subarea:
 Issue #:290989

Problem Description

One can save the time history of displacements in a TIM file if the SAVE option in the time history definition is included. In that report the displacements reported for a time step was that for a subsequent time step. In other words The results displacement reported at time 0.0 was actually the displacement for time DT.

Workaround

None

Solution

The issue is addressed in 20.07.11.90.

See Also

Tags: tim, 20.07.11.82, 661790, time history, known issue