Problem Description
One can save the time history of displacements in a TIM file if the SAVE option in the time history definition is included. In that report the displacements reported for a time step was that for a subsequent time step. In other words The results displacement reported at time 0.0 was actually the displacement for time DT.
Workaround
None
Solution
The issue is addressed in 20.07.11.90.