Current Revision posted to RAM | STAAD Wiki by Seth Guthrie on 5/12/2017 5:12:30 PM
Applies To | |||
Product: | RAM Frame | ||
First Affected Version: | |||
Found in Version: | 15.03.00 | ||
Fixed in Version: | |||
Area: | Graphics | ||
Issue #: | 119822 |
Problem Description
Nodal load moment values (Mxx, Myy and Mzz) do not display in Ram Frame using View - Nodal loads. Only the force components FX, FY and FZ are shown. For nodal loads that are moments only, nothing is displayed.
Reason
Missing functionality.
Solution
We are working on a fix for this issue. Meanwhile the loads can still be seen in Ram Modeler - Elevation view and the effects of the loads can be seen in the member forces, reactions and deflections within Ram Frame. So long as a small FX, FY or FZ component is included in the load definition, the load labels can also be shown in Ram Frame using View - Nodal loads.
Tags: Active, RAM Frame, RAM Structural System, graphics, known issue, defect