Quantcast
Channel: RAM | STAAD | ADINA Wiki
Viewing all articles
Browse latest Browse all 8748

Selfweight is not included in combinations for mat foundation job

$
0
0
Current Revision posted to RAM | STAAD Wiki by Sye on 5/1/2017 4:56:43 PM

 Applies To 
 Product:STAAD Foundation Advanced
First Affected Version:
 Found in Version:08.00.01.33
Released in Version:
Environment:All
 Area: General Foundation
Subarea:Mat Foundation
 Issue #:682345

Problem Description

When the selfweight is included as part of a primary load case, it is supposed to get included in all combinations involving that primary load case. However the software is currently not doing that and the selfweight is being left out from such combinations. This issue is specific to the mat foundation job type.

Steps to Reproduce

  1. In the attached model, the primary load case 1 has selfweight included as part of it.
  2. The load combination 101 is created by factoring load case 1 by a factor of 1.
  3. Run the analysis and open the .std file that is created by SFA.
  4. Note that the selfweight component is missing from the load case 101

(Please visit the site to view this file)

Workaround

Using the Add self weight and deadweight factor icon, add the self weight to all combination cases for which the self weight needs to be included as shown next

 

Solution

Will be addressed in the next release STAAD Foundation Advanced.

See Also

Tags: selfweight missing in combinations, known issue, 08.00.01.33, selfweight

Viewing all articles
Browse latest Browse all 8748

Trending Articles