Current Revision posted to RAM | STAAD Wiki by Sye on 4/28/2017 10:16:41 PM
Applies To | |||
Product(s): | STAAD.Pro | ||
Version(s): | All | ||
Environment: | N/A | ||
Area: | Design | ||
Subarea: | American Steel Design | ||
Original Author: | Bentley Technical Support Group | ||
I have multiple sets of design in the same STAAD file and I am only able to see the results for the final set in the Postprocessing mode (GUI). How can I view the results for all design sets in the GUI?
The postprocessing Beam >Unity Check page can report the design results only for the final set of design. This is a limitation in STAAD.Pro as the program architecture does not allow that results of multiple design sets to be made available at the same time graphically. The analysis output file is the only place where you can view results for all design sets. The only way to view the results of a previous design cycle graphically is
- to go to the editor and comment out the subsequent design sets and rerun the analysis
- reverse the order for the design data blocks so that the set, for which the GUI data is needed, becomes the last set.
Tags: LRFD, AISC ASD, multiple design, multiple, AISC 360, results for all design sets