Quantcast
Channel: RAM | STAAD | ADINA Wiki
Viewing all articles
Browse latest Browse all 8748

Deflection check for cantilever as per AISC Unified reporting infinity

$
0
0
Revision 1 posted to RAM | STAAD Wiki by Sye on 4/7/2017 12:49:33 AM

 Applies To 
 Product(s):STAAD.Pro
 Version(s):20.07.11.82
Environment:All
 Area: Steel Design
Subarea:AISC Unified
 Issue #:328300

Problem

When the CAN 1 parameter were assigned to members and these were checked for deflection as per the AISC 360-10 or AISC360-05 codes, the deflection check reported infinity as design result.

Reason

In case of CAN parameter, the x, y, z deflections were not being extracted correctly to compute the correct resultant deflection which lead to the problem

Workaround

None

Solution

Will be addressed in STAAD.Pro SS6 SP4 expected to be released in April/May of 2017.

 </

Tags: Active, STAAD.Pro, 20.07.11.82, 570801, known issue, defect