Quantcast
Channel: RAM | STAAD | ADINA Wiki
Viewing all articles
Browse latest Browse all 8748

Incorrect foundation loads under multi-story braces

$
0
0
Current Revision posted to RAM | STAAD Wiki by Seth Guthrie on 3/2/2017 11:26:47 PM

 Applies To 
 Product:RAM Foundation
First Affected Version:15.03.00.00
 Found in Version:15.03.00.00
Fixed and Released in Version:15.04.00.00
 Area: Design
 Issue #:541339

Problem Description

When a foundation supports a braced frame and the brace is one that spans across intermediate stories (modeled using Layout - Brace - Add Special) then the resultant reaction from the brace is absent in the foundation loads giving an unconservative design. 

Reason

The program is not seeing the brace when determining the foundation loads. 

Solution

The issue will be resolved in the release after v15.03.00. In the meantime, either revert to the prior version 15.02.00.00, or modify the braces so that they intersect a few inches above the base. This can be accomplished by re-modeling the braces using the "knee brace" standard configuration or by adding an extra short story at the base with only columns (and foundations) modeled.

Tags: design, 15.04.00, RAM Structural System, First 15.03.00, foundation, RAM Foundation, known issue, defect, Unconservative