Eurocode Section Classification for Section Subject to Flexure Only

$
0
0
Current Revision posted to RAM | STAAD Wiki by Seth Guthrie on 3/2/2017 11:23:43 PM

 Applies To 
 Product:RAM Steel
First Affected Version:
 Found in Version:15.02.00.00
Fixed and Released in Version:15.04.00.00
 Area: Design
 Issue #:492584

Problem Description

Members subject to flexure only and designed using the Eurocode were assigned to an incorrect section class. Members subject to axial load only or a combination of axial and flexure were correctly classified.

Reason

Members under pure flexure were given a classification of 1 when they could have been a higher class.

Solution

The issue will be resolved in the release after v15.03.00.