Current Revision posted to RAM | STAAD Wiki by Karl G on 2/24/2017 7:23:11 PM
Applies To | |||
Product: | RAM Concrete | ||
First Affected Version: | |||
Found in Version: | 15.03.00 | ||
Fixed in Version: | |||
Area: | Design | ||
Issue #: | 656199 |
Problem Description
In RAM Concrete Column, the program may have reported the shear in the minor axis as 0.0 when Eurocode2 was selected for the design code. This was a reporting error only. The program design was not affected.
Solution
Fixed in v15.04.00