Does STAAD Foundation Advanced perform Overturning and Sliding checks for MAT foundations ?
No. As of now, STAAD Foundation Advanced does not perform sliding or overturning checks for mat foundations. It does not do the bearing capacity checks either. However there is an indirect way of doing that using STAAD.Pro. When a mat foundation is analyzed in STAAD Foundation Advanced, it creates a STAAD.Pro model for the mat in the background. This file can be located as explained next
For STAAD Foundation Advanced Connect Edition ( ver 08.00.01.33 and up )
A folder by the same name as the STAAD Foundation Advanced (SFA) model name gets created at the same folder location where the SFA model is. That folder would contain a .std file with the same name as the SFA model name.
For versions prior to version 08.00.01.33
Within the installation folder of the software, there would be an Analysis folder ( example C:\Staad Foundation Advanced CONNECT Edition\Analysis ) which would contain a file named FoundationAnalysis.std.
The .std file mentioned above can be copied to a different folder and one can follow the procedure listed next to carry out the serviceability checks using STAAD.Pro
Note : All these checks are automatically carried out by STAAD Foundation Advanced for isolated footings or combined footings.